User manual 12/2010 mn04802060z-en replaces m000902-03, 10/2009 simatic s7 pg router.
Imprint 2 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com manufacturer eaton automation ag spinnereistrasse 8-14 ch-9008 st. Gallen schweiz www.Eaton-automation.Com www.Eaton.Com support region north america eaton corporation electrical sector 1111 superior ave. Cleveland, oh 44114 united ...
Proper use simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 3 proper use hardware, software, operating systems and drivers must only be used for the applications specified and only in conjunction with the components recommended by eaton automation ag. Warning no warranty claims will be reco...
Contents 4 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com contents 1 general ................................................................................................................ 5 1.1 scope of delivery ..............................................................................
1 general simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 5 1 g eneral the «s7 pg router» is an independent software package and is not part of the standard galileo package. The product must be purchased once and can be installed on any device for permanent use. Permanent use: the product ...
1 general 6 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 1.3 i nstallation on the p rogramming pc the «s7 pg router» setup wizard will be launched automatically once the installation cd is inserted in the cd drive. If the setup wizard does not launch automatically, run the file “s7pgrou...
1 general simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 7 important installation information appears. Confirm the subsequent dialog by clicking [next >]. The following dialog will ask you to select an installation directory. The selected directory must contain a galileo installation. Con...
1 general 8 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com select the directory in which the program shortcut will be created. Confirm the dialog by clicking [next >]. Confirm the subsequent dialog by clicking [install]..
1 general simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 9 the next dialog indicates that the installation was successfully completed. Confirm by clicking [finish]..
0 2 operating principle 10 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 2 o perating principle micro panels with an "onboard" mpi and ethernet interface support the s7 pg routing function. This function allows s7 controllers connected to the micro panel to be programmed via the micro pa...
3 creating a network simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 11 3 c reating a n etwork you should create a small network as shown in the following diagram in order to ensure that commissioning can be completed without any problems: note: the ip and mpi addresses shown are only give...
4 simatic manager settings 12 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 4 simatic m anager s ettings at least one of the following versions of the simatic manager is required in order to use the «s7 pg router» software: a) step7 v5.2 + net driver b) step7 v5.3 note: all the following...
4 simatic manager settings simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 13 4.1 a dding a r outer now add another s7-300 station to the project and call it the "router". In this case, this s7 station is simply a representative of the micro panel in the step7 project. Specify the "router”...
4 simatic manager settings 14 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com now move to the hardware settings tab of the "router" and add an s7 cpu with an ethernet interface. In the properties dialog, enter the ip address set on the micro panel ("router"). Connect the cpu with the ether...
4 simatic manager settings simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 15 4.2 c onfiguring the n etwork save the new hardware configuration once you have added the "router", and then move to the network configuration screen. The network configuration will now show you the "router" (mic...
4 simatic manager settings 16 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com now define a free mpi address for the "router" and select the mpi subnet..
4 simatic manager settings simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 17 for the pg/pc connection enter the ip address of the pc on which simatic manager is running, and select under subnet the already configured ethernet connection. Under assigned on the assignment tab, select "tcp/i...
4 simatic manager settings 18 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com the ethernet connection on the pg/pc highlighted in yellow indicates that the routing function is active. In our example, the s7 station (mpi address 2) can now be programmed via the micro panel (mpi address 31)....
5 micro panel settings simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 19 5 micro panel s ettings check beforehand that the ip address of the micro panel is the same as the address of the "router" station in the step7 project. In our example, this is 192.168.6.10. Now start the «s7 pg rout...
5 micro panel settings 20 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com you can also provide these settings as command-line parameters as described in chapter 9. The router connection is now fully configured and you can now access the connected s7 controller. When the pg connection is ac...
6 galileo settings simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 21 6 g alileo s ettings as mentioned at the start, the mpi interface can also be used by galileo and the g alileo r untime s ystem (grs) for data communication at the same time as the s7 routing function is active. Ensure t...
7 special features 22 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 7 s pecial f eatures 7.1 r estrictions the following pg functions are not supported by the "router": Î "who is online" poll of all active mpi stations 7.2 l imitations the general limitations of the s7 cpu with regard to...
8 error messages simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 23 8 e rror m essages simatic manager: if the simatic manager cannot set up a connection to the s7 cpu via the "router", use the following check list to check the installation: error cause mpi address conflict the same mpi ad...
9 command line reference 24 simatic s7 pg router 12/2010 mn04802060z-en www.Eaton.Com 9 c ommand l ine r eference s7route.Exe [-br br -sa sa -hsa hsa ] [-close] 9.1 p arameters parameter meaning values br baud rate 187500, 1500000 sa station address 0 to hsa hsa highest station address 15, 31, 63, 1...