Eberle Instat 868-r1 Installation And Operating Instrictions - page 2
5 Commissioning
Upon installation, a connection must be made be-
tween controller (transmitter) and receiver. For appli-
cation examples, see receiver instructions.
To do so, proceed as follows:
1. Activate “learning mode” on the receiver (see
there).
2. Activate “learning mode” on the transmitter as follows:
a) Hold the
ìì
-button depressed.
b) Briefly press the reset button.
c) When the indicator lamp lights up, release the
ìì
-button. When the connection has been suc-
cessfully made, the indicator lamp automatical-
ly extinguishes ( after approx. <1 min.).
d) Press the reset button on the transmitter. This
will terminate the “learning mode” and the indi-
cator lamp will extinguish.
Attention: Keep a distance of more than
2 m between transmitter and receiver.
Note:
When the learning mode is activated, the link with the
receiver is canceled first. The transmitter exits the
learning mode after 10 min.
5.1 Performance testing
The receiver has to be in the switching mode. After
pressing the reset button, the transmitter changes to
testing mode for 15 sec., different flashing signals are
transmitted to the receiver depending on the position
of the mode selector switch.
The flashing starts with a pause.
ê
ê
Permanent comfort temperature
The receiver flashes 3 times
ë
ë
Permanent setback temperature
The receiver flashes depending on the setback tem-
perature set (see 3.7 Function of the jumpers)
2 times for a 2 K temperature setback
1 time for a 4 K temperature setback
è
è
Automatic mode
The receiver flashes depending on the current time
zone of the master:
3 times for comfort temperature
2 times for standard temperature
1 time for setback temperature
í
í
OFF
The receiver does not flash.
Manual activation of receiver output
(not in OFF position):
In the case of a temperature differential exceeding 3
K (e. g. 30 °C or 5 °C), the receiver will be switched
on or off within 30 sec.
Switching on:
Set a temperature of 30 °C, wait approx. 30 sec.
Switching off:
Set a temperature of 5 °C, wait approx. 30 sec.
6 Technical data
Order No.
INSTAT 868-r1
EDP No.
0536 10…
Temperature setting range
5 ... 30 °C
Operating voltage
battery: 2 microcells
alkaline (LR03), 2 x 1,5 V = 3 V
Battery lifetime
approx. 3 years
Control mode
fuzzy logic with PWM
(selectable)
on-off action
PWM cycle time
approx. 10 min.
(sum of on and off times)
Measurement interval
approx. 10 min.
Indicator lamp
red, see 3.6
Function of indicator lamp
Mode selector switch
time switch / comfort /
depending on variant
setback / OFF
heating / cooling
Temperature setback/increase
by means of
mode switch
by approx. 2 K or 4 K (via jumper)
master
by 2 K and 4 K
Timer
1 ... 15 h
Valve protection
every 24 h (can be switched off)
Temperature sensor
in the controller
Carrier frequency
868,95 MHz
Modulation mode
FM
Antenna
internal
Transmission interval
<10 min.
(radio data transmision several times)
Typical range is
100 m free air or
1 ceilings or 3 walls respectively
Degree of protection provided
IP 30 (moisture
by enclosure
condensation not permitted)
Class of protection
III
Operating temperature
–25 ... 40 °C
Storage temperature
–25 ... 70 °C
Range narrowing
in adjustment knob
Weight (without battery)
approx. 100 g
The temperature controller is now ready for operation.
When testing the radio transmission, please observe
also the relevant receiver instructions.
7 Short form operating instructions
See
Preparatory work
3.7
●
Set jumpers according to their function
●
Insert battery
4
●
Install controller
Make radio link
5
1. Hold
ì button depressed
2. Briefly press reset button
3. When indicator lamp lights up, release
ì button
4. when the radio link has been succesfully made, press reset button.
Check transmitter function
5.1
After pressing the reset button, output switches
– permanent comfort temperature
ê
●
three times
– permanent setback temperature
Ñ
●
twice = temperature setback 2 K; once = temperature setback 4 K
– automatic mode
è
●
three times = comfort, twice = standard, once = temperature setback
– OFF
í
●
not
Switch receiver output
5.1
– output ON
●
set a temperature of 30 °C, wait for 30 sec.
– output OFF
●
set a temperature of 5 °C, wait for 30 sec.
Set mode of operation
3.2
– permanent day-time temperature
ê
●
permanent comfort temperatur
– permanent nighttime temperature
Ñ
●
permanent setback temperaturer (–2/4 K)
– automatic mode
è
●
automatic mode by using master
– OFF
í
●
OFF
Timer
3.4
acitvates comfort temperature
●
press
ì button once for every hour, indicator lamp flashes
for a limited period of time
●
press reset button to terminate
Check for correct operation
Press reset key
➝LED lights up briefly
➝receiver switches (see 5.1)
8 Application examples
Note:
In some rear cases it may not
be possible to establish a per-
manent radio link between the
radio transmitter and the radio
receiver. The cause of this
would not be in our radio con-
trol system, but in the frequen-
cy range to be used. We there-
fore recommend that the relia-
bility in operation at the specif-
ic location be checked. In par-
ticular the operation of a radio
headphone may be the cause
of radio interference.
Subject to change without
notice
9 Dimensions
Fig. 3: Time control with one master and slave controllers
INSTAT 868-r1
INSTAT 868-r1
INSTAT 868-r1
INSTAT 868-r
INSTAT 868-a1
INSTAT 868-a1
INSTAT 6-a1
Fig. 4: Pump logic with master and slaves
Burner
INSTAT 868-r1
INSTAT 868-r1
INSTAT 868-r
INSTAT 868-a1
Fig. 1: One transmitter controls one receiver
INSTAT 868-r1
INSTAT 868-a1
Fig. 2: Simple master/slave mode
INSTAT 868-r1
INSTAT 868-r
INSTAT 868-a1
RF approval has been obtained in the follo-
wing countries:
Germany, France, Great Britain, Belgium,
Netherlands, Luxembourg, Norway, Den-
mark, Sweden, Switzerland, Finland, Spain,
Italy, Austria, Ireland, Island, Portugal.
0125