Ebm-papst A3G710-AO81-03 Operating Instructions Manual

Manual is about: Axial Fan

Summary of A3G710-AO81-03

  • Page 1

    Operating instructions a3g710-ao81-03 translation of the original operating instructions ebm-papst mulfingen gmbh & co. Kg bachmühle 2 d-74673 mulfingen phone +49 (0) 7938 81-0 fax +49 (0) 7938 81-110 info1@de.Ebmpapst.Com www.Ebmpapst.Com contents 1. Safety regulations and information 1 1. Safety r...

  • Page 2

    Operating instructions a3g710-ao81-03 translation of the original operating instructions → wait five minutes after disconnecting the voltage at all poles before opening the device. Caution in the event of a fault, the rotor and the impeller will be energized the rotor and the impeller have basic ins...

  • Page 3

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 2. Intended use the device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and con...

  • Page 4

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 3. Technical data 3.1 product drawing all dimensions in mm. 1 direction of air flow "v" 2 max. Clearance for screw 16 mm 3 cable diameter min. 4 mm, max. 10 mm; tightening torque 2±0.3 nm 4 tightening torque 3.5...

  • Page 5

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 3.2 nominal data motor m3g112-ia phase 3~ nominal voltage / vac 400 nominal voltage range / vac 380 .. 480 frequency / hz 50/60 method of obtaining data ml speed / min -1 900 power consumption / w 930 current dr...

  • Page 6

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 3.5 mounting data ; secure the screws against unintentional loosening (e.G. Use self- locking screws). Strength class of screws 8.8 any further mounting data required can be taken from the product drawing. 3.6 t...

  • Page 7

    Operating instructions a3g710-ao81-03 translation of the original operating instructions caution electric shock voltage on metal part → use the device only with the cable guard and terminal box intended for it. Note device malfunctions possible route the device's control lines separately from the su...

  • Page 8

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 4.3.2 connecting wires to terminals warning live terminals and connections even with device switched off electric shock → wait five minutes after disconnecting the voltage at all poles before opening the device....

  • Page 9

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 4.4 connection diagram drawing preliminary! No. Conn. Designation function/assignment pe pe protective earth terminal kl1 1, 2, 3 l1, l2, l3 power supply 50/60 hz kl2 1 nc floating status contact, break for fail...

  • Page 10

    Operating instructions a3g710-ao81-03 translation of the original operating instructions 4.5 checking connections ; ensure isolation from supply (all phases). ; make sure a restart is impossible ; check the cables for proper fit. ; screw the terminal box cover back on again. Terminal box tightening ...

  • Page 11

    Operating instructions a3g710-ao81-03 translation of the original operating instructions line voltage faulty check line voltage, restore power supply. Attention! The error message resets automatically. Device restarts automatically without warning. Faulty connection isolate from supply, correct conn...

  • Page 12

    Operating instructions a3g710-ao81-03 translation of the original operating instructions the following section contains recommendations for ecological disposal of the product and its components. 6.3.1 country-specific legal requirements note country-specific legal requirements always observe the app...