Ebm-papst G3G200-GN18-01 Operating Instructions Manual

Manual is about: EC centrifugal fan

Summary of G3G200-GN18-01

  • Page 1

    Operating instructions g3g200-gn18-01 translation of the original operating instructions ebm-papst mulfingen gmbh & co. Kg bachmühle 2 d-74673 mulfingen phone +49 (0) 7938 81-0 fax +49 (0) 7938 81-110 info1@de.Ebmpapst.Com www.Ebmpapst.Com contents 1. Safety regulations and information 1 1. Safety r...

  • Page 2

    Operating instructions g3g200-gn18-01 translation of the original operating instructions → wait five minutes after disconnecting the voltage at all poles before opening the device. Caution in the event of a fault, the rotor and the impeller will be energized the rotor and the impeller have basic ins...

  • Page 3

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 1.11 transport note transporting the blower → transport the blower in its original packaging only. → secure the blower so it cannot slip, e.G. By using a lashing strip. Note transporting the device → transport t...

  • Page 4

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 3. Technical data 3.1 product drawing all dimensions in mm. Y detail y z view z / pin assignment 1 3-pole header, fits mating connector (not included in scope of delivery) tyco no. 350766-1, socket tyco no. 9268...

  • Page 5

    Operating instructions g3g200-gn18-01 translation of the original operating instructions you can control the blower either via the 0-10 vdc input or the pwm input. Attention: the inputs cannot be used simultaneously. 3.2 nominal data motor m3g084-df phase 1~ nominal voltage / vac 230 nominal voltage...

  • Page 6

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 3.6 transport and storage conditions ; use the device in accordance with its degree of protection. Max. Permitted ambient temp. For motor (transport/ storage) +80 °c min. Permitted ambient temp. For motor (trans...

  • Page 7

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 4.2.1 requirements ; check whether the information on the nameplate matches the connection data. ; before connecting the device, make sure the power supply matches the device voltage. ; only use cables designed ...

  • Page 8

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 4.4 connection diagram drawing preliminary! No. Conn. Designation function/assignment st1 1; 2; 3 l; n; pe power supply 230 vac, 50-60 hz, phase, neutral conductor, protective earth st2 1 ub external voltage 16-...

  • Page 9

    Operating instructions g3g200-gn18-01 translation of the original operating instructions 4.5 checking connections ; ensure isolation from supply (all phases). ; make sure a restart is impossible ; check whether the mating connector is properly engaged with the built-in connector. ; check that the ma...

  • Page 10

    Operating instructions g3g200-gn18-01 translation of the original operating instructions impeller not running smoothly imbalance in rotating parts clean the device; replace it if imbalance persists after cleaning. Make sure no weight clips are removed during cleaning. Motor not turning mechanical bl...

  • Page 11

    Operating instructions g3g200-gn18-01 translation of the original operating instructions ● cables and wires ● electronic scrap, e.G. Circuit boards only ferrite magnets and not rare earth magnets are used in external rotor motors from ebm-papst mulfingen gmbh & co. Kg. ; ferrite magnets can be dispo...