Ebm-papst K3G225-RE07-03 Operating Instructions Manual

Manual is about: size 225 mm

Summary of K3G225-RE07-03

  • Page 1

    Operating instructions k3g225-re07-03 translation of the original operating instructions ebm-papst mulfingen gmbh & co. Kg bachmühle 2 d-74673 mulfingen phone +49 (0) 7938 81-0 fax +49 (0) 7938 81-110 info1@de.Ebmpapst.Com www.Ebmpapst.Com contents 1. Safety regulations and information 1 1. Safety r...

  • Page 2

    Operating instructions k3g225-re07-03 translation of the original operating instructions → wait five minutes after disconnecting the voltage at all poles before opening the device. Caution in the event of a fault, the rotor and the impeller will be energized the rotor and the impeller have basic ins...

  • Page 3

    Operating instructions k3g225-re07-03 translation of the original operating instructions 2. Intended use the device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and con...

  • Page 4

    Operating instructions k3g225-re07-03 translation of the original operating instructions 3. Technical data 3.1 product drawing all dimensions in mm. 1 cable pvc awg20, 3x crimped splices 2 cable pvc awg22, 4x crimped splices 3 mounting dimensions item no. 51191-5-9970 · enu · change 89188 · approved...

  • Page 5

    Operating instructions k3g225-re07-03 translation of the original operating instructions 3.2 nominal data motor m3g055-df phase 1~ nominal voltage / vac 230 nominal voltage range / vac 200 .. 240 frequency / hz 50/60 method of obtaining data ml speed / min -1 2860 power consumption / w 170 current d...

  • Page 6

    Operating instructions k3g225-re07-03 translation of the original operating instructions 3.6 transport and storage conditions ; use the device in accordance with its degree of protection. Max. Permitted ambient temp. For motor (transport/ storage) + 80 °c min. Permitted ambient temp. For motor (tran...

  • Page 7

    Operating instructions k3g225-re07-03 translation of the original operating instructions 4.2.4 locked-rotor protection due to the locked-rotor protection, the starting current (lra) is equal to or less than the nominal current (fla). 4.3 connecting the cables the device has external leads. ; first c...

  • Page 8

    Operating instructions k3g225-re07-03 translation of the original operating instructions 4.4 connection diagram drawing preliminary! No. Conn. Designation color function/assignment con10 l black supply connection, power supply, phase, see nameplate for voltage range con11 n blue supply connection, p...

  • Page 9

    Operating instructions k3g225-re07-03 translation of the original operating instructions 4.5 checking connections ; ensure isolation from supply (all phases). ; make sure a restart is impossible ; check the cables for proper fit. 4.6 switching on the device the device may only be switched on if it h...

  • Page 10

    Operating instructions k3g225-re07-03 translation of the original operating instructions motor/electronics overtemperature deficient cooling improve cooling. Let the device cool down. To reset the error message, switch off the line voltage for at least 25 s and then switch it on again. Ambient tempe...

  • Page 11

    Operating instructions k3g225-re07-03 translation of the original operating instructions dispose of electronic components employing the proper procedures for electronic scrap. → please contact ebm-papst for any other questions on disposal. Item no. 51191-5-9970 · enu · change 89188 · approved 2016-0...