  • Page 1

    Operating instructions r4e250-cg01-01 translation of the original operating instructions ebm-papst mulfingen gmbh & co. Kg bachmühle 2 d-74673 mulfingen phone +49 (0) 7938 81-0 fax +49 (0) 7938 81-110 info1@de.Ebmpapst.Com www.Ebmpapst.Com contents 1. Safety regulations and notes 1 1. Safety regulat...

  • Page 2

    Operating instructions r4e250-cg01-01 translation of the original operating instructions caution in the event of failure, there is electric voltage at the rotor and impeller the rotor and impeller are base insulated. → do not touch the rotor and impeller once they are installed. Caution the motor re...

  • Page 3

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 2. Proper use the device is exclusively designed as a built-in device for moving air according to its technical data. Any other or secondary use is deemed improper and constitutes a misuse of the device. Install...

  • Page 4

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 3. Technical data 3.1 product drawing all measures have the unit mm. 1 connection line silicone, 6 x brass lead tips crimped 2 accessory part: inlet nozzle 25010-2-4013 and flange 94250-2-4017 not included in th...

  • Page 5

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 3.2 nominal data motor m4e110-gf phase 1~ 1~ nominal voltage / vac 230 230 frequency / hz 50 60 type of data definition ml ml valid for approval / standard - - speed / min -1 1270 1240 power input / w 640 820 cu...

  • Page 6

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 4. Connection and start-up 4.1 connecting the mechanical system caution cutting and crushing hazard when removing the fan from the packaging → carefully hold the impeller to remove the device from its packaging....

  • Page 7

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 4.3 connection of the cables external leads are brought out of device. ; first connect the "pe" (protective earth) connection. ● connect the lines according to your application. When doing so, observe chapter 4....

  • Page 8

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 4.4 connection screen top 2 x grey u1 blue z brown u2 black pe green / yellow item no. 10715-5-9970 · revision 82542 · release 2014-05-08 · page 8 / 10 ebm-papst mulfingen gmbh & co. Kg · bachmühle 2 · d-74673 m...

  • Page 9

    Operating instructions r4e250-cg01-01 translation of the original operating instructions 4.5 checking the connections ; make sure that the power is off (all phases). ; secure it from being switched on again. ; check the correct fit of the connection lines. 4.6 switch on device the device may only be...

  • Page 10

    Operating instructions r4e250-cg01-01 translation of the original operating instructions thermal overload protector responded allow motor to cool off, locate and rectify cause of error, if necessary cancel restart lock-out unacceptable operating point check operating point overtemperature of motor a...