EBS CPX200NB User Manual

Manual is about: ALARM CONTROL UNIT

Summary of CPX200NB

  • Page 1

    En alarm control unit cpx200nb user manual version of the manual: v1.6 date of issue: 2016.01.08 firmware version: 2.3.7 gprs transmitter configurator version: 1.3.54.10 osm server version: 1.3.53.3.

  • Page 2

    Cpx200nb alarm control unit – user manual 2 / 30 en declaration of compliance we, ebs sp. Z o.O., declare with full responsibility that the present product meets all requirements provided for in the directive 1999/5/ec of european parliament and council dated 9 march 1999 the copy of the “declaratio...

  • Page 3

    Cpx200nb alarm control unit – user manual 3 / 30 en content: 1. Introduction ........................................................................................................... 4 2. Control unit functions ..........................................................................................

  • Page 4: 1.  Introduction

    Cpx200nb alarm control unit – user manual 4 / 30 en 1. Introduction thank you for choosing ebs alarm control unit. Cpx200nb is a simple, functional alarm control unit integrated with gsm/gprs/sms transmitter, intended for small- and medium- sized facilities. The central unit is equipped with 3 outpu...

  • Page 5: 2.  Control Unit Functions

    Cpx200nb alarm control unit – user manual 5 / 30 en 2. Control unit functions 2.1. Functional characteristic zones 7 zones with the nc / no / eol-nc / eol-no / deol-nc / deol-no configuration possibility detection lines – instant, delayed, 24h burglary, arming/disarming, 24h tamper, interior delay, ...

  • Page 6

    Cpx200nb alarm control unit – user manual 6 / 30 en system options automatic diagnosis of basic system components possibility to review faults, alarm memories, event log system/technical event history – min. 5000 events 2.2. Electrical characteristic supply voltage: 18vac (16-20vac) required transfo...

  • Page 7: 3.  Keypad Specification

    Cpx200nb alarm control unit – user manual 7 / 30 en 3. Keypad specification power supply voltage: 10 – 13.8 vdc power consumption: typ. 20 ma, max. 80 ma keypad weight: 70 g size of casing: 99 x 82 x 19 mm keypad type: led, 16 status leds, 4 mode leds (alarm, armed, system, prog) button layout: stan...

  • Page 8

    Cpx200nb alarm control unit – user manual 8 / 30 en 1. Keypad buttons 0-9 buttons and * as well as # are intended for the keypad and alarm control unit operation. After first pressing any button, the keypad is backlit. After a few- second idle time, backlight gets automatically dimmed. In order to m...

  • Page 9

    Cpx200nb alarm control unit – user manual 9 / 30 en 10. Casing opening latch to open the casing it is recommended to use flat 2.5-5mm screwdriver. Insert it slightly in indicated hole and perform slight lever movement toward the rear side of the casing. 11. Anti-sabotage switch after the keypad is a...

  • Page 10: 4.  Arming The System

    Cpx200nb alarm control unit – user manual 10 / 30 en 4. Arming the system 4.1. Arming modes each partition can be armed in one of the following modes: stay (perimeter) – partition is armed, but only perimeter and perimeter exit zones violation will cause an alarm, away (full) – partition is armed an...

  • Page 11

    Cpx200nb alarm control unit – user manual 11 / 30 en 4.2.2. Away mode in order to arm the partition in the away mode, user has to input his code and press the button. Exit time countdown will start. Partition will arm in the stay mode in the following cases: 1. Partition has perimeter exit zones and...

  • Page 12: 5.  Disarming The System

    Cpx200nb alarm control unit – user manual 12 / 30 en 5. Disarming the system 5.1. Disarming the system 1. Enter the facility through the entrance door. Intermittent sound and slow flashing of armed led on the keypad will remind of the need to disarm the system before the delay time for entrance expi...

  • Page 13: 6.  Partition Handling

    Cpx200nb alarm control unit – user manual 13 / 30 en 6. Partition handling 6.1. Arming / disarming with selecting partitions 1. Enter the number of the function and confirm using . Then enter the user code and press . 3-tone beep will confirm the correct code input. Note: if incorrect code is entere...

  • Page 14

    Cpx200nb alarm control unit – user manual 14 / 30 en time for leaving expires. After it is armed the armed led will be constantly on. 3. If the partition arming in the stay mode was selected, system will arm immidiately. Armed led will turn on. 4. If partition disarming is selected, the relevant par...

  • Page 15: 7.  User Functions

    Cpx200nb alarm control unit – user manual 15 / 30 en 7. User functions 7.1. Alarms memory - display of alarms memory the function displays the history of alarms that occurred in the system. When the function is activated, alarm and prog leds are flashing slowly and all alarms that occurred since las...

  • Page 16

    Cpx200nb alarm control unit – user manual 16 / 30 en 7.2. Faults memory - display of faults memory the function displays the faults that are present in the system. When the function is activated, system and prog leds are flashing slowly and all faults that are currently present in the system are dis...

  • Page 17

    Cpx200nb alarm control unit – user manual 17 / 30 en 7 – other damages to display more detailed information about other damages, press button. 1 – clock fault 2 – fault of central unit settings 3 – keypads tamper to display more detailed information about keypads tamper, press button. 1 – keypad tam...

  • Page 18

    Cpx200nb alarm control unit – user manual 18 / 30 en to add a new user: 1. Enter the function code and press to confirm. 2. Enter the admin code and confirm it with . 3 beeps will confirm the correct code input. 3. Numbers of already existing users will be displayed. 4. Enter the id of newly added u...

  • Page 19

    Cpx200nb alarm control unit – user manual 19 / 30 en where: user code – code of a user changing the password code – new access code (from 4 to 7 digits) in any moment you can press to exit without saving changes. 7.7. Programming time you can change system time here. Time can be changed by the admin...

  • Page 20

    Cpx200nb alarm control unit – user manual 20 / 30 en duration of test is the time in seconds after which the test will be finished and the system will return to the main menu. After activation this function, leds 1 – 7 display the zones used in the system. Only zones belong to the user’s partitions ...

  • Page 21

    Cpx200nb alarm control unit – user manual 21 / 30 en – medical alarm – burglary alarm note – for the emergency buttons to work, it is necessary to be in arm/disarm ready mode and wait at least 10 seconds since last 0-9 key press. You can also press ‘*’ key to clear keypad buffer and use emergency bu...

  • Page 22

    Cpx200nb alarm control unit – user manual 22 / 30 en feedback message description partition1:x, partition2:y - information about partitions arm/disarm state. Partition1,partition2 – default partitions names, they can be changed with the setname command x,y – partition states, possibile values: 0 – d...

  • Page 23

    Cpx200nb alarm control unit – user manual 23 / 30 en getting the name of partition command syntax xxxx getname=partition,nr command description acquiring the name of the partition xxxx – user code nr – number of the partition, possibile values: 1 or 2 example: 1234 getname=partition,1 feedback messa...

  • Page 24

    Cpx200nb alarm control unit – user manual 24 / 30 en getting the phone number command syntax xxxx gettelnum=id command description getting the phone number for pointed index on the phone number list xxxx – user code id – index of phone number on the list, possible values: 1 to 10 example: 1234 gette...

  • Page 25

    Cpx200nb alarm control unit – user manual 25 / 30 en getting the content of text message command syntax xxxx getmessage=id command description getting the content of text message under the pointed index xxxx – user code id – index of text, possible values: 1 to 32 example: 1234 getmessage=30 feedbac...

  • Page 26

    Cpx200nb alarm control unit – user manual 26 / 30 en assigning a text message and a phone number to the event command syntax xxxx setusersms=event,telnum,msg_id command description assigning a text message and a phone number to the event. The text will be send to the phone number when this event occ...

  • Page 27

    Cpx200nb alarm control unit – user manual 27 / 30 en getting a text message content and a phone number assigned to the event command syntax xxxx getusersms=event command description getting the content of a text message and a phone number assigned to the specified event. Xxxx – user code event – a s...

  • Page 28

    Cpx200nb alarm control unit – user manual 28 / 30 en list of events handled by the setusersms and getusersms commands alias name description arm1 partition 1 armed armstay1 partition 1 armed in perimeter mode arm2 partition 2 armed armstay2 partition 2 armed in perimeter mode disarm1 partition 1 dis...

  • Page 29

    Cpx200nb alarm control unit – user manual 29 / 30 en battery-ok battery failure ended aux1-fail failure of auxiliary output 1 aux2-fail failure of auxiliary output 2 aux1-ok failure of auxiliary output 1 ended aux2-ok failure of auxiliary output 2 ended keypad1-lost (to keypad3-lost) failure of keyp...

  • Page 30

    Cpx200nb alarm control unit – user manual 30 / 30 en 8. The behavior of the system in compatibility mode for grade 2 the system operates in accordance with the en 50131 standard requirements for grade 2, i.E.: zones status is available only after user code has been entered information about alarms i...