EBS M7000 Installation Manual - page 2
4,7 x EOL
R = ----------------------
4,7 - EOL
R is the value of additional resistor (in k
Ω
) to add.
EOL is the value your panel expects (in k
Ω
).
To select the control signal for the lamp…
cut the jumper(s)
All options as above for the siren. Notes referring
to line monitoring are the same.
as above, but jumpers are
marked L, JL1 and JL2
On the ladder...
The sounder is equipped with one lamp, which should look down.
4. Position the sounder on the wall. The cables should go thru the hole on the left side of the sounder. Mark the place of the upper
mounting screw.
5. Drill the hole 12 mm dia. for upper mounting screw. Insert the plastic plug (delivered with the sounder). Mount the sounder.
6. Position the sounder. Mark 3 remaining holes.
7. Drill the holes, insert the plugs, mount the sounder firmly.
8. Connections
In the table below you can see the description of the connector of the sounder.
S
L
GND
+13,8
SAB (2 terminals)
R (2 terminals)
siren control
signal
lamp control
signal
ground
(supply
negative)
supply
positive
sabotage line (tamper),
polarity not important
EOL of sabotage
line
Connect:
¾
first EOL of sabotage line
¾
then sabotage line,
¾
controls,
¾
Power supply.
9. Fit the cover.
Main technical parameters
Power supply (nominal 13,8V)
9 – 15V
Current consumption (at 13,8V)
Quiescent
Alarm (acoustic only)
Alarm (optical only)
Alarm (acoustic and optical)
10 mA
200 mA
400 mA
600 mA
Control input current
+/-3 mA
Connectors
with screws
Weather protection of the pcb
special resin
Acoustic signal
piezoelectric driver
Tone choosing
jumper, 1 of 3
Tone 1
117 dB, at 1 m
Tone 2
116,5 dB, at 1 m
Tone 3
116 dB, at 1 m
Optical signal
4 Philips mini bulbs, 12V, 5W
Time of the flash
0,25 s
Frequency of the flashes
1 Hz
Colour
red
Protections
Tamper line with EOL according to panel
specification
Detection of foam
Detection of opening the housing
Detection of pulling the sounder from the wall
Housing
Polycarbonate
Diameter
24 cm
Environmental conditions
Operating temperature
-25
÷ + 70 deg. C
Storage temperature
-25
÷ + 70 deg. C
Humidity
100%