ECH2O Tec. 1000-BHL- 2 Owner's manual

Manual is about: BEACH HOUSE SERIES (VERTICAL SYSTEM)

Summary of 1000-BHL- 2

  • Page 1

    Beach house series (vertical system) 1000-bhl- 2 / 1300-bhl- 3 / 1800-bhl- 4 owners manual page 2 introduction 3 specifications 4 standard system features 5-6 installation instructions 7-8 operation instructions 9 membrane cleaning procedure 10 maintenance timetable 11 pressure vessel endplug changi...

  • Page 2

    Introduction thank you for choosing an echo tec. Reverse osmosis desalination system. We trust that you will be completely satisfied with our product. The beach house series has been specially designed for small hotels, marinas and beach houses. The high power efficiency and low maintenance cost mak...

  • Page 3

    Specifications rated performance: echo tec: 1000 – bhl – 2 min. 38 gallons – 143ltr. / hour 1300 – bhl – 3 min. 60 gallons – 227ltr. / hour 1800 – bhl – 4 min. 75 gallons – 284ltr. / hour reverse osmosis performance varies with the feed water temperature and salinity. The rated performance is tested...

  • Page 4: Standard System Features

    Standard system features aluminum vertical frame with shock mounted duplex stainless steel high pressure pump, control panels and ro vessels 2 filter housings with pleated polyester cartridges, 5 and 20 microns, 41/2” x 10” 1 filter wrench manual fresh water flush system pressure vessel(s) with reve...

  • Page 5: Installation Instructions

    Installation instructions mount the desalination system in a cool and dry location, not higher than 30ft above low water level at a distance not further than 100ft / 30m. The electrical connection should only be done by a professional electrician. Check the correct voltage before installing the syst...

  • Page 6

    Product water tubing run the blue product water tubing or for longer distances than 15ft / 5m a 1/2" pvc hose or pipe from the marked (tank) outlet of the flow control panel to your fresh water storage tank. Run blue product water tubing from the marked (test) outlet of the flow control panel to a t...

  • Page 7

    System operation instructions the reverse osmosis membrane contains a preservative solution to prevent microbiological growth. If ingested, may cause irritation of the gastro-intestinal tract, colic, diarrhea, or other similar symptoms. Therefore, discard all the product water for at least thirty mi...

  • Page 8

    Fresh water flush procedure caution: the fresh water pressure should not exceed the range of the low pressure gauge/s. The installation of a pressure reducer may be necessary. You should fresh water flush your watermaker after every use or infuse a biocide solution for long term storage. The fresh w...

  • Page 9

    Membrane cleaning procedure the membranes of the echo tec. Watermaker must be chemically cleaned when the product water output drops by 20% of the specified amount. The frequency of this occurring will vary greatly depending upon feed water. Fouling of the membranes will naturally occur during norma...

  • Page 10

    Maintenance timetable the following maintenance timetable is an estimate of the time intervals at which maintenance may be required only. This schedule must be adjusted to the regularity of usage, the condition of the intake water, the length of time the system is exposed to seawater and the total r...

  • Page 11

    Membrane changing procedure pressure vessel end plug changing procedure 1) remove the product port (if installed) and the high pressure fitting. 2) remove the two/three m6 bolts. 3) remove the two/three locking plates (locks) 4) remove the backing plate 5) pull the end plug with the aid of a hand ti...

  • Page 12

    110/ 220v 24v to highpressure pump to lowpressure pump mo tor st arter r1 mo tor st arter r2 trans - former st artswit chs1 pushbutt onno select orswit chs2 3-position ,maint . 4cont acts ,no t1 highpress . Swit chs4 nc lowpress . Swit chs5 no tankfull swit chs6 nc external main in electricaldiagram...

  • Page 13

    High pressure pump system troubleshooting guide malfunction cause remedy the pressure broken valve spring replace spring drops fouled inlet strainer clean strainer fouled pre-filter(s) replace filter cartridge(s) cavitation (noisy operation) check suction lines for restrictions air in system check s...

  • Page 14: Echo Tec Pump Series

    ∂ a ssembly - d isassembly o f t he p ump h ead 1.1-unscrewheadbolts. Tightening sequence of head bolts, for xt series and hpe series, for xr series and xl series. 1.2-removetheheadbyrotatingtheshaftandlevering betweenheadandbody. 1.3-forre-assembly:invertaboveinstructions,andkeep totorqueratesshown...

  • Page 15

    3.2-disassemblethecomponentsofthepistonguide, checkingthecondition,replaceifnecessary. 3.3-forre-assembly:invertoperation. R eplacing the pistons 4.1-removethehead(see∂),thenunscrewthepiston retainers. 4.2-slideofftheceramicpstions,checktheircondition, andreplaceifnecessary. 4.3-forre-asembly:invert...

  • Page 16

    Echo tec. Watermaker limited warranty echo marine ltd. Warrants to the original purchaser for a period of twelve (12) months from the date of shipment that the echo tec. Watermaker will perform according to specifications. Echo marine’s liability under this warranty shall be limited to repair or rep...

  • Page 17

    The echo tec. Membrane element is guaranteed to be cleanable for a minimum of one year from date of shipment, or commissioning of the system by echo marine ltd, provided that cleaning instructions are adhered to and foulant is acid soluble metal hydroxides and calcium carbonates or alkaline soluble ...