ECHO MARINE 1200-PRO- 3 Owner's manual

Manual is about: VERTICAL SYSTEM 230V / 50HZ

Summary of 1200-PRO- 3

  • Page 1

    Pro series vertical system 230v / 50hz 500-pro-1 / 900-pro- 2 1200-pro- 3 / 1500-pro- 4 owners manual page 2 introduction 3 specifications 4 standard system features 5 installation instructions 6-7 operation instructions 8 membrane cleaning procedure 9 maintenance timetable 10 pressure vessel endplu...

  • Page 2

    Introduction thank you for choosing an echo tec. Reverse osmosis desalination system. We trust that you will be completely satisfied with our product. The beach house series has been specially designed for small hotels, marinas and beach houses. The high power efficiency and low maintenance cost mak...

  • Page 3

    Specifications rated performance : echo tec: 500 – pro – 1 min. 20 gallons – 75ltr. / hour 900 – pro – 2 min. 38 gallons – 140ltr. / hour 1200 – pro – 3 min. 50 gallons – 210ltr. / hour 1500 – pro – 4 min. 60 gallons – 260ltr. / hour reverse osmosis performance varies with the feed water temperature...

  • Page 4

    Standard system features 1) fully assembled desalination system in aluminum vertical flame with shock mounted 316ti high pressure pump, control panels, ro vessels and 5 and 20 micron cartridge filtration system. 2) 1 fresh water flush kit with hose and 316ss hose clamps 3) 1 product water tube 10ft ...

  • Page 5

    Installation instructions position the desalination system in a cool and dry location. Mount the system using all four mounting holes. The electrical installation should only be done by a professional electrician. Check the correct voltage before installing the system. The cable labeled with the sys...

  • Page 6

    System operation instructions the reverse osmosis membrane contains a preservative solution to prevent microbiological growth. If ingested, may cause irritation of the gastro-intestinal tract, colic, diarrhea, or other similar symptoms. Therefore, discard all the product water for at least thirty mi...

  • Page 7

    Fresh water flush procedure caution: the fresh water pressure should not exceed the range of the low pressure gauge/s. The installation of a pressure reducer may be necessary. You should fresh water flush your watermaker after every use or infuse a biocide solution for long term storage. The fresh w...

  • Page 8

    Membrane cleaning procedure the membranes of the echo tec. Watermaker must be chemically cleaned when the product water output drops by 20% of the specified amount. The frequency of this occurring will vary greatly depending upon feed water. Fouling of the membranes will naturally occur during norma...

  • Page 9

    Maintenance timetable the following maintenance timetable is an estimate of the time intervals at which maintenance may be required only. This schedule must be adjusted to the regularity of usage, the condition of the intake water, the length of time the system is exposed to seawater and the total r...

  • Page 10

    Membrane changing procedure pressure vessel end plug changing procedure 1) remove the product port (if installed) and the high pressure fitting. 2) remove the two/three m6 bolts. 3) remove the two/tree locking plates (locks) 4) remove the backing plate 5) pull the end plug with the aid of a hand tig...

  • Page 11

    110/ 220v 24v to highpressure pump to lowpressure pump mo tor st arter r1 mo tor st arter r2 trans - former st artswit chs1 pushbutt onno select orswit chs2 3-position ,maint . 4cont acts ,no t1 highpress . Swit chs4 nc lowpress . Swit chs5 no tankfull swit chs6 nc external main in electricaldiagram...

  • Page 12

    High pressure pump system troubleshooting guide malfunction cause remedy the pressure worn packing seals replace seals drops broken valve spring replace spring fouled inlet strainer clean strainer fouled pre-filter(s) replace filter cartridge(s) cavitation check suction lines for restrictions water ...

  • Page 13

    High pressure pump repair instruction series ep-12-34 / ep-14-34 / ep-17-34 disassembly sequence of the front end of the ech 2 o tec. High-pressure pump. Refer to the pump diagram. 1) remove the three discharge valve plugs and the three inlet valve plugs (32), with a 22 mm socket wrench. Inspect the...

  • Page 14

    5) should you find it necessary to service the plunger assembly (16), you can do so by removing the tension screw (16d). Inspect all parts and replace as necessary. Note: in order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase ...

  • Page 16

    Echo tec. Watermaker limited warranty echo marine ltd. Warrants to the original purchaser for a period of twelve (12) months from the date of shipment that the echo tec. Watermaker will perform according to specifications. Echo marine’s liability under this warranty shall be limited to repair or rep...

  • Page 17

    The echo tec. Membrane element is guaranteed to be cleanable for a minimum of one year from date of shipment, or commissioning of the system by echo marine ltd, provided that cleaning instructions are adhered to and foulant is acid soluble metal hydroxides and calcium carbonates or alkaline soluble ...