• 12 x M8 cabinet flying points
• Available in black or white finish
ARQISSB15
• 1-way architectural subwoofer
• 600 WRMS @ 8 Ω
• 15" woofer
• Double INPUT/STACK connector, Speakon© type
• 35 mm top-hat mount socket, for pole mount combinations with ARQIS10,
ARQIS12, etc.
• 8 x M8 cabinet flying points.
• Available in black finish
C O NNE C TI O NS
The connection cables which connect the amplifiers output and the speaker should be
of good quality, have sufficient conductor area and be as short as possible. The latter
fact is especially important when the distance is long and the load impedance low (4-8
). A cross-section of at least 2.5mm
2
is recommended for distances up to 10m; 4 or
6mm
2
for longer distances. Following formula gives the required section, assuming
4% losses:
Always respect the polarity. All models have an Euroblock connector, and a
second connector (Euroblock or Speakon®, depending on model), thereby
facilitating the parallel connection of speakers.
RE C O MME N D E D A M P L IF I E R
Following table shows the output power of the amplifier adequate to each acoustic
system:
ARQIS 105: between 70 and 150W RMS
ARQIS 106: between 120 and 250W RMS
ARQIS 108: between 150 and 300W RMS
ARQIS 205: between 150 and 300W RMS
ARQIS 208: between 300 and 600W RMS
ARQIS 110: between 220 and 450W RMS
ARQIS 112: between 340 and 700W RMS