Ecler eMOTUS5OD User Manual - page 5
5
important when the distances to cover are considerable and the impedance of the
loudspeakers is low.
(*) N.B. The speaker distribution system on a 100V/70V line historically arises from
the technical need to mix loudspeakers with different impedances and/or power
ratings on the same line or amplifier channel, all without the need to be concerned
about the total impedance of the resulting unit. In addition to that, this solution
makes it possible, with minimum losses of power, to use long stretches of cable and a
slightly shorter section than that normally used in a low impedance installation.
CAUTION!
eMOTUS5OD is delivered by default with the switch in the 100V/30W position. If the
system is accidentally connected to an amplifier with a low impedance output,
no damage will be done to the loudspeaker, but it will perform well below its
capacity. In the event of accidentally connecting the loudspeaker to a 100V
network with the switch in the 8
position, it will be seriously damaged.
PO S IT IO NI N G
,
FI TT IN G A ND ST A R T
-
U P
In the packing of eMOTU5OD, you will find all that is needed to complete installation
of the unit.
The following should be observed as general rules:
Always install on solid, firm surfaces.
For good sound reproduction, there should be no hindrance between the
units and the audience.
Adjust the levels of sound pressure to reproduction requirements. Despite
its small size, the eMOTUS5OD has a performance far higher than that of
domestic loudspeakers.
Procedure for installing on a surface:
1. Make three 6 mm drill holes in the wall, lining them up with the position of
the holes in the bracket.
2. Insert three 6 mm wall plugs in these holes.
3. Fasten the safety line on the back of the bracket.