    I table of contents 1 intelligent speed dome installation.................................................. 1 1.1 installation environments .....................................................................................................................1 1.2 check installation space and installa...

  • Page 3

    Ii 4 wall mount bracket installation...................................................... 10 4.1 component installation.......................................................................................................................10 4.2 wall mount installation steps ...........................

  • Page 4

    Iii 9 appendix Ⅳ12v ac wire gauge and transmission distance relationship sheet .......................................................................................... 20 10 appendix v wire gauge reference sheet ........................................ 21.

  • Page 5: Welcome

    Iv welcome thank you for purchasing our speed dome! Please read the following safeguards and warnings carefully before you install or use the product!.

  • Page 6: Safety Measures

    V important safeguards and warnings safety measures 1. Qualified engineer needed z the installation engineer or maintenance engineer shall have corresponding cctv system installation certificate or maintenance qualification certificate. Z the installation engineer or maintenance engineer shall have ...

  • Page 7: Note

    Vi 7. All the examination and repair work should be done by the qualified service engineers. We are not liable for any problems caused by unauthorized modifications or attempted repair. Note 1. Safety transportation z heavy stress, violent vibration or water splash are not allowed during transportat...

  • Page 8

    Vii z do not use gasoline, dope thinner or other chemical material to clean the shell. It may result in shell transfiguration or paint flake. Z do not allow the plastic or rubber material to touch the shell for a long time. It may result in paint flake..

  • Page 9

    1 1intelligent speed dome installation 1.1installation environments basic requirement z all installation and operation here should conform to your local electrical safety codes. Z before installation, please open the package and check all the components are included. Please make sure the speed dome ...

  • Page 10

    2 2setup before installation 2.1check accessories before the installation, please check the accessories one by one according to the packing list. Please make sure all the components listed are included. 2.2open device this section is for intelligent analog speed dome, intelligent network speed dome,...

  • Page 11

    3 2.4dial switch setup (for analog speed dome only) the following operation is based on the ceiling mount speed dome. Here we are going to set speed dome address, baud rate and etc. There are two dial switches on the ptz for you to set address, baud rate and etc. See figure 2-2. Figure 2-2 2.4.1 dia...

  • Page 12

    4 figure 2-3 there are two dial switch buttons on the ptz. You can use them to set speed dome address, baud rate, and parity respectively. It is 1 when you set the button as on. For the protocol dial switch, you can refer to the following sheet. 1 is the lowest bit and the 8 is the highest bit. Plea...

  • Page 13

    5 on on none 2.4.3 address the address interface is shown as in figure 2-5. Figure 2-5 the encode mode adopts binary system. 1 to 8 is valid bit. The highest address bit is 255. You can refer to the following sheet for more information. Address 1 2 3 4 5 6 7 8 1 off off off off off off off off 1 on ...

  • Page 14

    6 if you want to connect the 120Ω resistance, please remove the jumper from the pin 2 and pin 3 and connect to pin 1 and pin 2. Now the 120Ω is connected to the circuit. See figure 2-8. Figure 2-8.

  • Page 15

    7 3ceiling mount 3.1installation components the ceiling mount installation component is shown as in figure 3-1. Figure 3-1 3.2ceiling mount installation steps 3.2.1 installation environments the ceiling mount speed dome can be installed in the hard construction wall in the indoor environments. Befor...

  • Page 16

    8 3) in figure 3-2, pull the cable according to your cable exit mode. And then use four screws (working with insulated sleeve) to secure the pedestal of ceiling mount speed dome on the ceiling. Turn the screws to the plastic expansion bolts. Figure 3-2 4) in figure 3-3, line up the arrow symbol on t...

  • Page 17

    9 3.2.3 cable connection the step listed below is for ceiling, in-ceiling or wall mount series product. Please connect the power cable, video output cable, rs485 control cable, alarm input/output pin of the intelligent speed dome composite cable according to your actual requirements. Pleas use insul...

  • Page 18

    10 4wall mount bracket installation 4.1component installation the wall mount bracket and outdoor speed dome is shown as in figure 4-1. Figure 4-1 4.2wall mount installation steps 4.2.1 installation environments the wall mount speed dome can be installed in the hard construction wall in the indoor or...

  • Page 19

    11 figure 4-2 3) dig holes in the wall according to the installation holes at the bottom of the wall mount bracket. Please make sure the cable exit of the bracket is facing the round hole of the wall. Insert expansion bolts (not provided) to the holes you just dug. Connect the composition cable and ...

  • Page 20

    12 now the installation is complete. See figure 4-4. Figure 4-4.

  • Page 21

    13 5in-ceiling mount bracket installation 5.1component installation the in-ceiling bracket and speed dome body is shown as below. See figure 5-1. Figure 5-1 5.2installation 5.2.1 installation requirements the in-ceiling mount speed dome can be installed in the hard construction wall in the indoor en...

  • Page 22

    14 figure 5-2 connect the composition cable and then put the cable to the hole you just dug. Push the in- ceiling bracket and dome body to the hole you just dug. Turn the fastening screw to secure the hanging board. See figure 5-3. Figure 5-3 in figure 5-4, use three screws to secure the in-ceiling ...

  • Page 23

    15 figure 5-4 after the installation, the interface is shown as in figure 5-5. Figure 5-5.

  • Page 24

    16 6appendix Ⅰ thunder proof and surge protection this series speed dome adopts tvs lighting protection technology. It can effectively prevent damages from various pulse signals below 4000w, such as sudden lighting and surge. While maintaining your local electrical safety code, you still need to tak...

  • Page 25

    17 7appendix Ⅱ about rs485 bus 7.1rs485 bus main feature rs485 is semi duplex communication cable of impedance 120Ω. Its max load amount is 32 effective loads (including main control device and devices to be charged). 7.2rs485 bus transmission distance when we take 0.56mm (24awg) twisted-pair as com...

  • Page 26

    18 figure 7-2 7.4rs485 bus faq phenomenon possible reasons solution speed dome can run self- diagnosis but i can not control it. Z host address(baud rate) and speed dome address(baud rate) are not match; z positive and negative end of rs485 bus are misconnected; z connection cable is loose; z rs485 ...

  • Page 27

    19 8appendix Ⅲ the 24v ac wire gauge and transmission distance relationship sheet it is the recommended transmission distance when the cable diameter is fixed and the 24v ac power consumption is below 10%. For the ac device, the max permission voltage power consumption is 10%. For example, when a de...

  • Page 28

    20 9 appendix Ⅳ12v ac wire gauge and transmission distance relationship sheet the recommended max transmission distance is under the following environments: the wire diameter is fixed and the dc 12v power voltage loss rate is below 10%. For the device of dc power supplying, the max allowed voltage l...

  • Page 29

    21 10appendix v wire gauge reference sheet metric bare wire diameter ( mm) awg swg bare wire cross section ( mm 2 ) 0.050 43 47 0.00196 0.060 42 46 0.00283 0.070 41 45 0.00385 0.080 40 44 0.00503 0.090 39 43 0.00636 0.100 38 42 0.00785 0.110 37 41 0.00950 0.130 36 39 0.01327 0.140 35 0.01539 0.160 3...