    In s ta ll a ti o n a n d o p e ra ti o n m a n u a l room air conditioners bravo inverter range split type dc inverter eco916sd eco1216sd eco1816sd eco2416sd register your air conditioner model information can be found on the ce label. Please register your product online at www.Ecoair.Org. For your...

  • Page 2: Warning

    Warning: before operating your unit make sure the wiring is adequate for your unit. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker complies with the amp rating listed in figure 1. Do not use an extension cord. The cord provided will carry the proper...

  • Page 3

    Bs plug wiring (for models up to 12000 btu) wiring instructions: should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : blue - neutral brown – live green and yellow - earth as the colours of the wires in the mains lead o...

  • Page 4

    Congratulations! You have purchased the very latest in room air conditioner technology. Your new ecoair high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your ecoair air conditioner to assure quiet operation, the best circulation ...

  • Page 5

    Operation and maintenance-notices for operation ★ earth: the ground ★ be sure to remove the power ★ select the most appropriate tem- be connected! Plug when not using the air co- perature. Nditioner for a long time. Keep room cool- er than outside about 5 degree. If not, please ask the qualified per...

  • Page 6

    Notices for operation ★ the airflow direction can be adjusted appro- ★ if the supply cord is damaged, it must be replaced priately. At operating, adjust the vertical airflow by the manufacturer or its service agent or a direction by adjusting the louvers of upward/do- similarly qualified person in o...

  • Page 7

    Notices for use working principle and special functions for cooling principle: the air conditioner transfers heat from the indoor area to the outdoor area, thus reducing the indoor room temperature, using heat pump technology. Anti-freezing function: in cool mode under low ambient temperature, frost...

  • Page 8

    Notices for use working temperature range indoor side db/wb( o c) outdoor side db/wb( o c) maximum cooling 32/23 48/ - 21/15 minimum cooling 10/- maximum heating 27/--- 24/18 minimum heating 20/--- -15/- the operating temperature range (outdoor temperature) for cooling unit is 21℃ ~ 43℃; for cooling...

  • Page 9

    Names and functions of each part indoor unit air in ⑴ ⑶ ⑹ ⑸ ⑷ air out ⑵ wireless remote control cool dry heat power on/off receive window ⑺ (1) power cable (2) remote control (3) front panel (4)filter (5)guide louver outdoor unit (6)wall pipe air in (7)bind tape (8)drainage pipe ⑻ air out 5.

  • Page 10

    Operation of remote control names and functions of remote control buttons note: ensure there is no obstruction between the indoor unit and the remote control; don't drop or throw the remote control; don't spill any liquid onto remote control. Do not put the remote control directly under the sunlight...

  • Page 11

    Operation of remote control names and functions of remote control buttons note: this remote control may have some buttons that are not available to your model. Fan auto oper air health x-fan humidity filter turbo hour on/off on/off mode fan remote control x-fan temp timer turbo sleep light health sa...

  • Page 13

    Operation of remote control guide for operation-general operation 1.Press on/off button to start the unit after powering the main unit on.(note: the big -guide louver and small-guide louver will close automatically during power on). 2.Press mode button to select desired running mode. 3.Press +/ - bu...

  • Page 14

    Operation of remote control ★ about auto run when auto run mode is selected, the setting temperature will not be displayed on the lcd, the unit will be in accordance with the room temp. Automatically to select the suitable running method and to make ambient comfortable. ★ about turbo function if sta...

  • Page 15

    Emergency operation display indicator light control of indoor unit it's a special selective button for the users, who are not accustomed to the light at sleeping. ● get the display indicator light on: when setting the light function, the mark will display on the remote controller screen by pressing ...

  • Page 16

    Clean and care caution ● turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. ● never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. ● volatile liquid (e.G. Thinner or gasoline) will d...

  • Page 17

    Clean and care check before use ① be sure that nothing obstructs the air outlet and intake vents. ② check that ground wire is properly connected or not. (important) ③ check that the batteries of the remote control changed if remote is not working. ④ check that the installation stand of the outdoor u...

  • Page 18

    Troubleshooting caution don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Problem troubleshooting not operate immediately when the air ● once the air conditioner...

  • Page 19

    Troubleshooting troubleshooting problem • has the power been shut down? The unit is not running. • is power connected properly? • is the circuit protection device tripped off or not? • is voltage higher or lower? (tested by professionals) breaking off • is the timer correctly used? • is temp. Settin...

  • Page 20

    Troubleshooting problem no air delivery from indoor unit. Moisture on air outlet vent. Troubleshooting ● in heat mode, when the indoor temperature is very low, air delivery will be delayed for up to 5 minutes. ● in heat mode, when the outdoor temperature is low or high humidity, frost may form on th...

  • Page 21

    Notices for installation important notices 1. Installation work must be done by competent or qualified persons according to local rules and this manual. 2. All electric supply to the unit must be carried out by qualified electrician. 3. Reinstallation of the unit must be carried out by qualified per...

  • Page 22

    Notices for installation outdoor unit installation position selection 1. Select a location from which noise and outflow air emitted by unit will not be a nuisance to neighbours, animals or plants. 2. Select a location where there should be sufficient ventilation. 3. Select a location where there sho...

  • Page 23

    Installation dimension diagram installation dimension diagram space to the ceiling above above space to the wall above above air outlet side space to the floor ● the dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent st...

  • Page 24

    Install indoor unit install the rear panel 1.Always mount the rear panel horizontally. The outlet of water tray should be adjusted slightly downward when installing to enable gravity flow of condensation externally. 2.Fix the rear panel on the wall with screws. . . . . (where is pre-covered with pla...

  • Page 25

    Install indoor unit note: where the electric cable length is not long enough, replace with another that is long enough as joints on the cables are not to be avoided. Ensure the replacement cable is of the same quality and diameter. ● the electric wiring must be correctly connected, wrong connection ...

  • Page 26

    Install outdoor unit electric wiring disassemble the handle on the outdoor unit 1. Right side plate. 2. Take off cord anchorage. Connect and fix power connect cord (for cooling and heating unit, connect and fix power connect cord and signal control wire)to terminal block. 3. Fix the power connection...

  • Page 27

    Check after installation and test operation check after installation items to be checked has it been fixed firmly? Have you done the refrigerant leakage test? Is heat insulation sufficient? Is water drainage well? Is the voltage in accordance with the rated voltage marked on the nameplate? Is the el...

  • Page 28: Installation Instructions

    Installation and maintenance of healthy filter installation instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter downwards to remove it. (see fig. A) 2. Mount the healthy filter onto the air filte...

  • Page 29

    One (1) year limited warranty save this warranty information ecoair guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must...