Eco Air ECO20LDK User Manual

Summary of ECO20LDK

  • Page 1

    Users manual read this manual inside you will find many helpful hints on how to use and maintain your dehumidifier properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your dehumidifier. You'll find many answers to common problems in the...

  • Page 2

    Page 2 congratulations on your purchase of the smart & fresh eco20ldk carbon filter dehumidifier you have purchased a high quality dehumidifier capable of extracting humidity of 20 litres per day at 80%rh 30 ℃ . This unique unrivalled dehumidifier is packed full of features that you will find benefi...

  • Page 3

    Page 3 7) silent mode on indicator 8) humidity reading - displays ambient humidity when is on and displays set humidity when symbol is off. (to display set humidity level, press △▽ button once. Reading will revert to ambient humidity level after 3 seconds). 9) dry mode on indicator 10) ambient room ...

  • Page 4

    Page 4 index safety precautions……………………………………………..5 bs plug wiring………………………………………………….6 ambient environment for operating…………………………7 components diagrams ……..…………………………………7 operating instructions functions of control panel & key pads ……………………………..8 lcd monitor ……………………………………………….…….9 operation of key...

  • Page 5

    Page 5 safety precautions 1 ) do not place your dehumidifier close to other high temperature appliance to avoid fire or damage. 3 ) always ensure unit is upright, do not use when unit is not upright or at a slanted angle. Disconnect unit if unit topples over. Leave unit upright for at least 2 hours ...

  • Page 6

    Page 6 bs plug wiring wiring instructions: should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code: blue - neutral brown - live green and yellow – earth as the colours of the wires in the mains lead of this appliance may no...

  • Page 7

    Page 7 ambient environment for operating 1. The appliance is designed to provide an optimum performance within ambient temperature range of 5 ℃ to 35 ℃ 2. Operate the unit indoors in your house or office, etc. Never use it in a wet environment such as bathroom or outdoors. 3. Make sure the door and ...

  • Page 8

    Page 8 operating instructions functions of control panel & key pads 1. On / off: power on / off 2. Silent: press the button to activate and deactivate silent mode 3. Conti.: press to dehumidify continuously. (also used as laundry mode) 4. Timer: set timer on of off 1 – 8 hours 5. Swing: oscillation ...

  • Page 9

    Page 9 lcd monitor 1) fan speed indicator 2) water full indicator 3) continuous / laundry mode indicator 4) timer (1-8 hour) reading 5) swing function indicator 6) auto defrost indicator 7) silent mode on indicator 8) humidity reading - displays ambient humidity when is on and displays set humidity ...

  • Page 10

    Page 10 operation of keys pads plug into power socket: the unit will beep 3 times, air louvre goes into closed position. Modes 1) auto 2) manual 3) continuous 1) auto mode switching on auto mode press on button to switch on auto mode. • the unit will beep once to indicate power on • the dry key will...

  • Page 11

    Page 11 2) manual mode switching on manual mode press △▽ button to select desired humidity level. Your humidity level can be selected in frequencies of 5%, ranging from 40% to 80%. • your dehumidifier will be set at your selected humidity level. (pressing the △ or ▽ once will display the set humidit...

  • Page 12

    Page 12 3) continuous mode switching on continuous mode press cont button. Will appear on the lcd display. • your dehumidifier will run continuosly. • the fan will be at high fan speed. Pressing the △▽ symbol or symbol will reset the dehumidifier to the auto mode. Timer: you can set your dehumidifie...

  • Page 13

    Page 13 automatic defrosting: a working cycle: when ambient temperature drops to 16 ℃ or lower, the compressor may go into automatic defrosting mode. The compressor will run for a further 25 minutes then will shut down and goes into defrost mode. The fan blower continues to run for 7 minutes to defr...

  • Page 14

    Page 14 continuous drainage remove water plug and connect with pvc hose to the spigot maintenance & cleaning before any maintenance or cleaning, switch off and unplug the unit. Do not place the unit in direct sunlight. Remove the water tank with care. If not using the unit for a long period, switch ...

  • Page 15

    Page 15 specification model eco20ldk power rated 220-240vac/50hz moisture removal 20 l/d (30 ℃ rh80%) dehumidifying power 360w (30 ℃ rh80%) dehumidifying air volume l speed:130m 3 /h h speed: 165m 3 /h refrigerant r134a / 160 grams capacity of water tank 4.5l unit dimension: 366 (w) × 330 (d) × 590 ...

  • Page 16

    Page 16 service and warranty two (2) year limited warranty save this warranty information ecoair guarantees this product free from defects in materials and workmanship of the unit (filters are excluded) for a period of two (2) years from the date of purchase. This unit must be operated under conditi...

  • Page 17

    Page 17 responsible disposal & recycling when your appliance reaches the end of its life, please dispose responsibly. Do not: you must not dispose this appliance as unsorted waste or with your domestic household waste. Please observe local regulations for disposal. • most local authorities have spec...