Eco Angus Max Multi Fuel Installation, Operation And Maintenance Manual

Manual is about: Angus Max Multi Fuel Boiler

Summary of Max Multi Fuel

  • Page 1

    Angus max multi fuel boiler installation, operation and maintenance manual.

  • Page 2

    Index information on the boiler plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 boiler dimensions, boiler packaging dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3

    Installation, operation and maintenance manual 1 information on the boiler plate the boiler serial no. Is shown on the plate which is attached to the cover panel of the cast iron body. Fig. 01.

  • Page 4

    Installation, operation and maintenance manual 2 boiler dimensions boiler packaging dimensions notice: please obey to the meanings of the symbols on packaging for health care fig. 02 fig. 03 series angus max-04 angus max-05 angus max-06 angus max-07 angus max-08 angus max-09 angus max-10 l (mm) 673 ...

  • Page 5

    Installation, operation and maintenance manual 3 technical parameters boiler type angus max-04 angus max-05 angus max-06 angus max-07 angus max-08 angus max-09 angus max-10 number of elements pcs. 4 5 6 7 8 9 10 nominal heat output (black coal – walnut) kw 35.0-38.0 44.0-48.0 54.0-58.0 63.0-67.5 73....

  • Page 6

    Installation, operation and maintenance manual 4 a table of the angus max heating area *** for cold climate and low insulation houses, max heating area should be decreased approximately 10% *** for mild climate and strong insulation houses, max heating area should be increased approximately 10% for ...

  • Page 7

    Installation, operation and maintenance manual 5 introduction 1. The boiler and all associated equipment must be installed and used in accordance with the installation design, all applicable legal regulations and technical standards and with the manufacturer’s instructions. The boiler may be used on...

  • Page 8

    Installation, operation and maintenance manual 6 head losses fig. 04 operating instructions angus max series boiler – general features ■ angus max series solid fuel fired boiler is designed for heating both residential and industrial buildings. ■ besides professional installation, precondition for c...

  • Page 9

    Installation, operation and maintenance manual 7 control and safety devices angus max boilers are equipped with three main control elements: a chimney flap (fig. 05), by means of which the chimney thrust can be controlled, i.E. The discharge of combustion fumes into the chimney. The flap is situated...

  • Page 10

    Installation, operation and maintenance manual 8 supply of secondary combustion air is controlled by an air rosette (fig. 08), situated in the boiler’s stoking door, which has a direct effect on the level of emission. Hot water temperature can be checked on a thermometer (fig. 09), which is situated...

  • Page 11

    Installation, operation and maintenance manual 9 hydraulic connection diagram it is suggested that open type hydraulic system should be installed according to following schemes. Open expansion tank system fig. 10 1. Safety heat exchanger (sht) 6. Four way mixing valve 2. Safety valve (ts 131, sts 20...

  • Page 12

    Installation, operation and maintenance manual 10 1. Boiler 4. Safety valve (ts 131, sts 20) 2. Open expansion tank 5. Four way mixing valve 3. Radiator fig. 11 1. Boiler 2. Laddomat 21-60 operated by flue thermostat – 50-300°c 3. Nad or nado accumulator tank 4. Immersion heater 5. Three way mixing ...

  • Page 13

    Installation, operation and maintenance manual 11 fig. 13 fig. 14 1. Boiler 2. Laddomat 21-60 operated by flue thermostat – 50-300°c 3. Nad or nado accumulator tank 4. Immersion heater 5. Three way mixing valve 6. Circulating pump 7. Room thermostat 8. Heating system outlet 9. Open expansion tank 10...

  • Page 14

    Installation, operation and maintenance manual 12 fig. 15 fig. 16 1. Boiler 2. Safety group (automatic air vent, pressure reducing valve and pressure gauge) 3. Dhw cylinder 4. Ch pump 5. Heating system 6. Four way mixing valve 7. Nrv 8. Expansion vessel 9. Accumulator tank 10. Three way valve 11. Va...

  • Page 15

    Installation, operation and maintenance manual 13 putting the boiler into service checking the boiler before turning it on before putting the boiler into operation, the service technician must check: ■ whether the installation conforms with the design; ■ whether the boiler has been filled in and is ...

  • Page 16

    Installation, operation and maintenance manual 14 setting the outlet water temperature when the required outlet water temperature is say 60°c, heat up the boiler to a temperature for instance 5°c higher than the required temperature of 60°c (measured on the thermometer on the boiler outlet pipe). Th...

  • Page 17

    Installation, operation and maintenance manual 15 important information ■ the boiler may only be operated by an adult familiar with these operating instructions. ■ shut the boiler down every time there are any (even temporary) flammable or explosive fumes present on the premises from which combustio...

  • Page 18

    Installation, operation and maintenance manual 16 please note ashes should be stored (by using proper glove) in a non-combustible container properly and transported outdoors. Other waste must not be stored in this container. Fig. 17 fig. 18 fig. 19 fig. 20

  • Page 19

    Installation, operation and maintenance manual 17 boiler repairs the boiler may be repaired by an authorised service technician or organisation only. The user or owner may do only normal maintenance and simple replacements of some parts – e.G. Sealing cords. Please note when repairing the boiler, or...

  • Page 20

    Installation, operation and maintenance manual 18 installation instructions boiler installation – general information angus max boilers must be put into service by an authorized services. A network of authorised service organisations which meet these conditions is available for all boiler installati...

  • Page 21

    Installation, operation and maintenance manual 19 boiler location angus max boilers can be located both on non – habitable premises (e.G. In boiler room, cellar, corridor) and in habitable rooms. The room in which the boiler is located must have a permanent supply of air necessary for the combustion...

  • Page 22

    Installation, operation and maintenance manual 20 boiler room disposition layout fig. 22 illustrates minimum distances which must be kept in order to ensure safe operation of the boiler room and allow manipulations with the boiler, such as cleaning and stoking. The distance between the front of the ...

  • Page 23

    Installation, operation and maintenance manual 21 angus max boiler parts fig. 23 fig. 24.

  • Page 24

    Installation, operation and maintenance manual 22 spare parts list fig. 25 item description drawing no part number angus max-04 angus max-05 angus max-06 angus max-07 angus max-08 angus max-09 angus max-10 1 front section sx 001500111 sx-md.060 sx-md.060 sx-md.060 sx-md.060 sx-md.060 sx-md.060 sx-md...

  • Page 25

    Installation, operation and maintenance manual 23 accumulator tank capacity note: the heat can be supplied for example by an accumulator tank. The following applies as a reference for the minimum storage boiler content: v sp : accumulator tank capacity in l q n : nominal heat output in kw t b : burn...

  • Page 26

    Installation, operation and maintenance manual 24 flue pipe installation fig. 27 shows the proper flue gas connection with additional air equipment. Observe the following during the installation of the flue gas connection: ■ install a flue pipe connection with an inspection aperture for cleaning. ■ ...

  • Page 27

    Installation, operation and maintenance manual 25 the figures below are only guide figures. The draft depends on the diameter, height, roughness of the chimney wall, and the temperature difference between combustion products and the outside atmosphere. We recommend the use of a chimney liner. Have p...

  • Page 28

    For more information please visit our website www.Ecoangus.Co.Uk 01934 862642 07739 174511 07970 901273 ecoangus@aol.Com 2068. Designed and produced by.