Eco-ideal CVSECI05FM Instructions For Installation/operation/maintenance/servicing

Summary of CVSECI05FM

  • Page 1

    1 jineci05 rev. E. 11/11/2014 eco-ideal inset 5 mkii model: cvseci05fm instructions for: installation/operation/maintenance/servicing approved for use in the united kingdom and the republic of ireland.

  • Page 2

    2 jineci05 rev. E. 11/11/2014 contents index: important information……………………………………………………………………………………………… 3 user instructions………………………………………………………………………………………………………… 5 techincal specification………………………………………………………………………………………………. 9 pre installation requirments…………………………………………………………………………………… 10 install...

  • Page 3

    3 jineci05 rev. E. 11/11/2014 g eneral g uidance this appliance has been certified for use in the countries stated on the cover. Installation in other countries will require translated instructions and may also require modification to comply with local regulations. It is important that your stove is...

  • Page 4

    4 jineci05 rev. E. 11/11/2014 f ire c ement some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact, wash immediately with plenty of water. A sbestos this stove contains no asbestos. If there is a possibility of disturbing any asbestos i...

  • Page 5: User Instructions

    5 jineci05 rev. E. 11/11/2014 user instructions please read the ‘general guidance’ section at the start of these instructions before operating your stove for the first time. Allow sufficient clearance between the stove and pictures, plasma screen televisions or ornaments etc., as these could be dama...

  • Page 6

    6 jineci05 rev. E. 11/11/2014 m ultifuel g rate your eco-ideal stove is fitted with a locomotive type grate. So that de-ashing can be carried out cleanly and easily, it is riddled from the outside of the stove with the doors closed. The grate is designed to burn both wood and solid mineral fuels. G ...

  • Page 7

    7 jineci05 rev. E. 11/11/2014 de-ash before refuelling and do not let the ash level reach the underside of the grate bars. Solid mineral fuel produces ash, which if allowed to build-up will stifle the airflow through the primary air inlets and grate. This will eventually cause the fire to die. With ...

  • Page 8

    8 jineci05 rev. E. 11/11/2014 c lean a ir a ct 1993 and smoke control a reas under the clean air act 1993 local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from a...

  • Page 9

    9 jineci05 rev. E. 11/11/2014 technical specification: eco-ideal inset 5 mkii eco-ideal inset 5 mkii hunter stoves, emperor way, exeter business park, exeter, devon. Ex1 3qs bs/en 13229 ukas# 0692 stove mass: 100 kg nominal output: 4.9 kw co emission at 13% o 2 : 0.19% mean flue gas temperature: 292...

  • Page 10

    10 jineci05 rev. E. 11/11/2014 pre-installation requirements w arning ! You run the risk of serious health problems if the products of combustion enter the property. P lease check the following : any existing chimney/flue system must be confirmed as suitable for this appliance as defined in building...

  • Page 11: Installation Instructions

    11 jineci05 rev. E. 11/11/2014 f lue outlet p ositions (d ocument j): position on roof clearances to flue exit a at or within 600mm of the ridge at least 600mm above the ridge b elsewhere on a roof (pitched or flat) at least 2.3 m horizontally from the nearest point on the weather surface and: a) at...

  • Page 12

    12 jineci05 rev. E. 11/11/2014 c ompetent p ersons s cheme members of the following schemes may self-certify the installation of this stove. If the installer is not a member of one of these schemes, your local building control department must approve the installation. Scheme web address telephone ap...

  • Page 13

    13 jineci05 rev. E. 11/11/2014 f ireplace d imensions (fire surround and side wall shown are combustible and all dimensions stated are minimum) r emoving i nternal c omponents all internal components must be removed prior to fitting the stove. This will make handling the stove easier; allow access t...

  • Page 14

    14 jineci05 rev. E. 11/11/2014 6. Pull the baffle forward and to the left hand side, allowing the right hand edge of the baffle to drop down into the stove, and remove. You can now remove the upper rear brick. 7. Unscrew the 2 m6 screws and remove the turbo bars. 8. Pull the top edge of the lower si...

  • Page 15: Installing The Stove

    15 jineci05 rev. E. 11/11/2014 12. Slide the cam to the left until the right hand side is clear of the hole, then raise one side and swing out through the door opening. 13. Remove the ash barrier by sliding out of the stove. Installing the stove 1. Unpack the stove. 2. Remove internal components. 3....

  • Page 16: Commissioning And Handover

    16 jineci05 rev. E. 11/11/2014 commissioning and handover appliance c heck please check that all components are correctly assembled and working correctly. Ensure the door catch mechanism is adjusted correctly and the 12mm rope seals around the door are air tight and sealing. Ensure the air controls ...

  • Page 17: Maintenance & Servicing

    17 jineci05 rev. E. 11/11/2014 maintenance & servicing warning ! No unauthorised modification of this appliance should be carried out. Important ! In order to ensure continued compliance with current building regulations and local authority byelaws, this appliance requires regular maintenance by a c...

  • Page 18

    18 jineci05 rev. E. 11/11/2014 only wire-centred sweeps’ brushes fitted with a guide wheel should be used. If it is not possible to sweep all parts of the chimney through the appliance, ensure there is adequate access to cleaning doors. If the stove is fitted in place of an open fire, then the chimn...

  • Page 19: Spares And Stove Care

    19 jineci05 rev. E. 11/11/2014 spares and stove care single door assembly single door (hce09008) glass clip (hhr08146) glass clip screw (fsjm05008ss) single door glass (hce09102) single door gasket (hce09101) door handle assembly (hce09arrt043s) rope sealing kit (scpcb900sdrsk-revc).

  • Page 20: Left Hand Door Assembly

    20 jineci05 rev. E. 11/11/2014 left hand door assembly right hand door assembly left hand door (tdi05008) glass clip (hhr08046) glass clip screw (fsjm05008ss) double door glass (hce09031) double door gasket (hce09030) right hand door (hce09009) rope sealing kit (scpcb900ddrsk) glass clip (hhr08046) ...

  • Page 21: Body Assembly Components

    21 jineci05 rev. E. 11/11/2014 body assembly components top air deflector single door: (hcn05arrt023) double door: (hcn05arrt024) fuel retainer (hcn05arrt030) baffle (hcn05022) upper rear brick (hcn05072) lower rear brick (hcn05070) riddling support (hcn05069) riddling bars: side: (cnn05004 a&b) upp...

  • Page 22

    22 jineci05 rev. E. 11/11/2014 commissioning & installation checklist purchase information dealer/retailer name address telephone number email date purchased installer information installer name address telephone number email appliance information date installed appliance stock code appliance descri...

  • Page 23: Service Records

    23 jineci05 rev. E. 11/11/2014 service records 1 st service date of service date of next service servicing company/ engineer signature 3 rd service date of service date of next service servicing company/ engineer signature 5 th service date of service date of next service servicing company/ engineer...

  • Page 24

    24 jineci05 rev. E. 11/11/2014.