Eco-ideal Inset eco 8 Installation And Operating Instructions Manual

Manual is about: Multi-Fuel Inset Stove

Summary of Inset eco 8

  • Page 1

    Jineci08 revc 21/05/14 inset eco 8 multi-fuel inset stove installation and operating instructions.

  • Page 2: Inset Eco 8

    Jineci08 revc 21/05/14 inset eco 8 technical specification this appliance is not for use in a shared flue this appliance is suitable for intermittent burning this stove has been designed and assembled so that it may be used to burn wood logs in a smoke control area. Find out if you are in a smoke co...

  • Page 3

    Jineci08 revc 21/05/14 general guidance it is important that your stove is correctly installed as hunter stoves cannot accept responsibility for any fault arising through incorrect use or installation. These instructions cover the basic principles to ensure satisfactory installation of the stove, al...

  • Page 4

    Jineci08 revc 21/05/14 f ume e mission warning note properly installed, operated and maintained, this appliance will not emit fumes into the dwelling. The appliance door(s) must be kept closed at all times, except for when de-ashing and refueling, during which occasional fumes may occur. However, pe...

  • Page 5

    Jineci08 revc 21/05/14 a ir s upply the room or space containing this appliance should have purpose provided ventilation (where necessary) in accordance with building regulations. Due consideration should be given to air requirements for any other appliance in the same room or space. Any air opening...

  • Page 6

    Jineci08 revc 21/05/14 the diameter of the flue should not be less than 150mm and not more than 200mm. If these requirements are not met the chimney should be lined by a suitable method. If there is no existing chimney then either a prefabricated block chimney in accordance with building regulations...

  • Page 7

    Jineci08 revc 21/05/14 c learances to c ombustible m aterials excluding some fire surround installations (see below) there should be no combustible material within 200mm of either side of the stove or 275mm above. No combustible furniture should be placed any closer than 700mm from the front of the ...

  • Page 8

    Jineci08 revc 21/05/14 4. Slide the side bricks out. 5. Remove the rear bricks. 6. Remove the lower rear brick support using the finger hole provided to lift it from its slots. 7. Cut the cable ties and remove the baffle by rolling it up over the baffle supports and out of the stove. 8. Remove the g...

  • Page 9

    Jineci08 revc 21/05/14 10. Remove the catch bar/front plate. 11. Detach the cam bar linkage arm from the front cam bar, rotate the cam bar and lift it out. 12. Lift out the rear cam bar along with the cam bar linkage arm. 13. Lift out the primary air duct. 14. Lift out the primary air valve slider. ...

  • Page 10

    Jineci08 revc 21/05/14 16. Slide the primary air valve control arm all the way to the left. I nstallation i nstructions 1. Using the diagram below, mark and drill a hole using a 6mm drill bit to a depth of 70mm. 2. Slide the stove into position, ensuring that the sealing rope is compressed against t...

  • Page 11

    Jineci08 revc 21/05/14 alternatively a connection can be made using a register plate although it will be necessary to allow access for fitting the flue pipe to the register plate, infilling with vermiculite concrete and sealing all joints. R e -a ssembling t he s tove refit all the internal parts by...

  • Page 12

    Jineci08 revc 21/05/14 c ommissioning & h andover upon completion of the installation allow a suitable period of time for any fire cement and mortar to dry out. A small fire may then be lit and the installation checked to ensure the smoke and fumes are drawn up the flue and emitted safely to atmosph...

  • Page 13

    Jineci08 revc 21/05/14 r iddling g rate your hunter stove is fitted with a locomotive type grate. So that de-ashing can be carried out cleanly and easily, it is riddled from the outside of the stove with the doors closed. B urning w ood pull the operating tool down and towards you. When left in this...

  • Page 14

    Jineci08 revc 21/05/14 further information on the requirements of the clean air act can be found here: http://smokecontrol.Defra.Gov.Uk/ your local authority is responsible for implementing the clean air act 1993 including designation and supervision of smoke control areas and you can contact them f...

  • Page 15

    Jineci08 revc 21/05/14 rope- check the rope around the door. If rope is becoming detached, use hunter stoves rope glue to reattach it. If the rope is in a poor condition, a replacement rope kit may be ordered from the hunter stoves spares range. Chimney & flue ways- it is important that the chimney,...

  • Page 16

    Jineci08 rev b 14/02/13 spares information single door spares spares information double door spares l.H. Door (tdi05/008) door glass (hce09/102) glass gasket (hce09/101) glass clip (hhr08/046) glass screw (fsjm05008ss) rope sealing kit (scphce09sdsk) glass gasket (hce09/030) glass clip (hhr08/046) g...

  • Page 17

    Jineci08 rev b 14/02/13 spares information single door body spares.

  • Page 18