Eco Range Oil Condensing Boiler Instructions For Use Installation And Servicing

Summary of Oil Condensing Boiler

  • Page 1

    Eco range cooker oil condensing boiler model for use in great britain and eire (gb & ie) instructions for use, installation and servicing this appliance must be installed in accordance with the regulations in force and only used in an adequately ventilated space. Please read these instructions befor...

  • Page 2

    1. Introduction thank you for choosing to purchase the condensed oil, balanced flue, eco range cooker. Each cooker is manufactured and assembled by hand in our factory. This appliance is designed to be capable of operating for long periods of time. With correct installation and use your eco range co...

  • Page 3

    This appliance is very heavy and every care should be taken when trying to manoeuvre it. Do not attempt to move or lift the appliance by the door handles, this could cause damage to the doors and handles. It must be sited on a solid, level floor constructed in accordance with any building regulation...

  • Page 4

    Safety notices and regulations the building regulations – part j england and wales – part f section iii scotland – part l northern ireland – part j ireland. Bs5440 parts 1 and 2 installation of flues and ventilation. D.M.2. Installation of timber framed buildings. Safety document 635 the electricity...

  • Page 5

    Ovens - height 270mm depth 500mm width 345mm your cooker is fitted with a thermostatic control device. This operating system provides the exact heat requirements selected (by the user) for cooking and reduces the overall oil consumption. The user selects the desired cooking temperature and when the ...

  • Page 6

    4.4 cleaning your cooker caution: cleaning of the eco range cooker should only be carried out when the appliance has cooled down. The eco range cooker should be wiped over daily with a damp soapy cloth. The enamel should then be dried and polished with a soft dry cloth to avoid streaking. Any spilla...

  • Page 7

    The warranty will become invalid if you strip and rebuild the cooker yourself. 5.1 site considerations 1. Sufficient space for appliance, so that access for service and maintenance purposes can be easily attained. 2. Provision of a satisfactory flue/chimney/cowl. 3. A sold non-combustible hearth cap...

  • Page 8

    5. With the supplied tape and silicon make a seal on the inner and outer pipes. Push into the cooker, whilst making sure no excess sealant has leaked that may block the cooker spigots. Ensure minimum of 3º drop. 6. With suitable material make a good flue hole. 7. Fit the terminal to the pipes whilst...

  • Page 9: Boiler:

    Boiler: introduction thank you for choosing our condensing oil boiler, please read the following carefully. To the installer this manual must be left with the householder by the installer who will instruct the user on the boiler operation. To the user please read the user section of this manual to f...

  • Page 10

    Boiler operation the boiler control thermostat responds to the temperature of the water within the boiler and switches power to the burner when heat is required. The burner has an independent control system which regulates the firing and (shut-off) of the burner. Automatic firing of the burner will ...

  • Page 11

    Switching the boiler off the boiler can be switched off at anytime using one of the following: - turn the boiler control thermostat to the off position - switch the mains (electrical supply) to off - set the control system to off (e.G. Time clock) please note: for longer periods of shutdown e.G. Whi...

  • Page 12

    The burner reset button on the control box illuminates to indicate that a lockout has occurred. In the event of the burner locking out, do not attempt to restart the burner by pressing the reset button on the burner control box for at least 2 minutes. A bi-metallic timer within the control box has a...

  • Page 13

    Water connections only two connections for the heating and hot water system on a standard condensing boiler: 1. Flow from top of boiler (fig.2) and return to top of stainless steel heat exchanger (fig.2). 2. The pvc pipe (fig 3) is 21.5mm Ǿ and should continue from the condensate trap in side the bo...

  • Page 14

    Recommended flue position.

  • Page 15

    Oil supply.

  • Page 16

    A flexible oil pipe is supplied to connect the burner to the incoming oil supply pipe. Important notes: - if sitting oil tank above burner height, use single supply pipe only. - if sitting oil tank below burner height, use twin pipe supply or tiger loop. - please refer to burner manual for conversio...

  • Page 17

    Note: 28 sec fuel must only be used on eco range cookers & boilers servicing instructions a competent service engineer oftec registered should be appointed on an annual basis. Remove inspection door, burner and baffle assembly brush down the inside of the heat exchanger and vacuum out debris clean b...

  • Page 18

    Boiler size no. Of inserts from l/h side of condenser remaining tubes without inserts 15/21 kw 10 6 1 set of baffles 15/21 kw.

  • Page 19: Burner Settings

    Burner settings boiler model 15/21 maximum output btu/hr 72000 kw/hr 21 factory setting btu/hr 63000 kw/hr 18.5 nozzle size 0.55 80 deg h oil pressure bar 8 burner air setting 7 smoke 0 co 2 % 11.5 flue gas temperature °c 80 water inlet/return mm 22 water outlet/flow mm 22 condensate flow mm 22 pvc ...

  • Page 20

    Electrical entry the electrical supply to the boiler must be 230v/50hz, fused at 5 amps. Connection of the appliance and any system controls, to the mains supply, must be a common isolator and must be fused at 5a maximum. This must be fixed wired to a double pole-isolating switch that has a maximum ...

  • Page 21

    Set central heating controls so they are calling for heat. Set burner pump pressure. Allow time for the boiler to reach normal operating temperature. Check the smoke reading. Measure the co 2 measure net flue gas temperature. Check domestic hot water flow and hot temperature is acceptable to the hou...

  • Page 22

    Boiler will not start check if mains electricity supply is reaching boiler control panel, making sure control thermostat is turned on and time clock is calling for heat. Mains indicator green should be illuminated. If green light is not illuminated and fuse has been checked then heating system charg...

  • Page 23

    Warranty registration guarantee your cooker now has a one year parts and labour guarantee and a further four year parts guarantee. It is the responsibility of the installer to ensure that the cooker is properly commissioned. This must be by a qualified technician. It is essential that the commission...

  • Page 24

    Warranty registration appliance model serial number date of commissioning: customer details customer name: (in block capitals) address: town: county: postcode: customer signature commissioning technicians details technician’s name: (in block capitals) technician’s competent persons oftec registratio...

  • Page 25

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 26

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 27

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 28

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 29

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 30

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 31

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 32

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 33

    Service record appliance model serial number date of service: engineer details engineer's name: (in block capitals) engineers registration number engineer's signature date combustion analysis cooker boiler pump pressure co 2 % co ppm flue gas temperature co/co2 efficiency % engineer's comments: jet ...

  • Page 34

    This publication or any part of it cannot be copied by any means without the prior written consent of the authors. Our products are subject to continuous development and improvement and it is consequently acknowledged that errors and omissions may occur. This publication is intended only to assist t...

  • Page 35

    Eco range cookers 60 wincheap canterbury kent ct1 3rs info@ecorangecooker.Co.Uk www.Ecorangecooker.Co.Uk.