Ecoair ECO1206SQ Installation and operation manual

Manual is about: DC INVERTER QUICK COUPLING SERIES R410A Split Type

Summary of ECO1206SQ

  • Page 1

    In s ta ll a ti o n a n d o p e ra ti o n m a n u a l room air conditioners r410a split type dc inverter quick coupling series eco906sq eco1206sq t please read this installation manual completely before installing the product. T when the power cord is damaged, replacement work shall be performed by ...

  • Page 2

    Congratulations! You have purchased the very latest in room air conditioner technology. Your new ecoair high efficiency room air conditioner will give you many years of dependable service. Many features have been built into your ecoair air conditioner to assure quiet operation, the best circulation ...

  • Page 3: Warning

    Warning: before operating your unit make sure the wiring is adequate for your unit. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker complies with the amp rating listed in figure 1. Do not use an extension cord. The cord provided will carry the proper...

  • Page 4: Bs Plug Wiring

    Bs plug wiring (for models up to 12000 btu) wiring instructions: should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : blue - neutral brown – live green and yellow - earth as the colours of the wires in the mains lead o...

  • Page 5

    ȝ ȝ ȝ operation and maintenance-notices for operation ȝ ȝ be sure to pull out the power ȝ ȝ ȝ ȝ earth: the ground be connected! If not, please ask the qualified person- nel to install. Furthermore, don't conn- ect each wire to the gas pipe, water pipe, drainage pipe or any other impr- oper places. P...

  • Page 6

    Notices for operation ★ the airflow direction can be adjusted appro- ★ if the supply cord is damaged, it must be replaced priately. At operating, adjust the vertical airflow by the manufacturer or its service agent or a direction by adjusting the louvers of upward/do- similarly qualified person in o...

  • Page 7

    Notices for use working principle and special functions for cooling principle: the air conditioner transfers heat from the indoor area to the outdoor area, thus reducing the indoor room temperature, using heat pump technology. Anti-freezing function: in cool mode under low ambient temperature, frost...

  • Page 8

    Notices for use working temperature range indoor side db/wb( o c) outdoor side db/wb( o c) maximum cooling 35/24 48/30 21/15 minimum cooling 21/- maximum heating 24/--- 21/15.5 minimum heating 20/--- -15/- the operating temperature range (outdoor temperature) for the cooling is 21 ℃ ~ 48 ℃ and for t...

  • Page 9

    Names and functions of each part Ņ ň Ń ʼn Ł ł ņ Ņ ł ň ʼn ń Ň Ń Ł indoor unit air in air out outdoor unit wireless remote control air in air out power cable remote control front panel filter guide louver wall pipe bind tape connection wire drainage pipe ń ņ Ň ˖ cool ˖ dry ˖ fan ˖ heat ˖ se t temp. ˖ ru...

  • Page 10

    ƽ press this button to select light on or off in the display. When the light on is light button light set,the icon will be displayed and the indicator light in the displayer will be on. When the light off is set, the icon will be displayed and the indicator light on the display will be off. Names an...

  • Page 11

    ƽ after powered on, the setting temperature displaying is defaulted, (according to customers requirements to display, if there is no requirement that will default to display the presetting temperature and there is no icon displayed on wireless remote control). Press this button, (when displaying ) ,...

  • Page 12

    Off ƽ press this button to activate or deactivate the up and down swing function. ƽ press this button, to set up swing angle, which circularly changes as below: swing up and down button timer on timer on button timer on setting: signal “on” will blink and display, signal will conceal, the numerical ...

  • Page 13

    ȝ this function indicates that moisture on evaporator of indoor unit will be blowed after about blow function the unit is stopped to avoid mould. 1. Having set blow function on: after turning off the unit by pressing on/off button indoor fan will continue running for about 10 min. At low speed. In t...

  • Page 14

    Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, the icon will be displayed on it, in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear. 1. Press swing up and down button c...

  • Page 15

    If the wireless remote control is lost or broken, please use the manual switch auto mode, but the temperature and fan button. At this time, the unit will run at the to open the panel, the manual switch is on the displayer box. It's a special selective button for the users, who are not accustomed to ...

  • Page 16

    đ ● ● ● đ ś clean the air filter Ŝ Ś d e clean and care caution turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile liqui...

  • Page 17

    Ś be sure that nothing obstructs the air outlet and intake vents. ś Ŝ check that the batteries of the remote control changed if remote is not working. ŝ check that the installation stand of the outdoor unit is damaged or not. If damaged, please contact the dealer. Ś ś Ŝ ŝ Ş clean and care check befo...

  • Page 18

    Once the air conditioner is stopped, it will not operate in approximately 3 minutes to protect itself. ƽ ƽ ƽ ƽ ƽ ƽ troubleshooting caution don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it ca...

  • Page 19

    ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ ƽ troubleshooting phenomenon troubleshooting the unit is not running has the power been shut down? Is power connected properly? Is the circuit protection device tripped off or not? Is voltage higher or lower? (tested by professionals) is the timer correctly ...

  • Page 20

    ƽ ƽ ƽ ƽ troubleshooting phenomenon troubleshooting no air delivery from indoor unit. Moisture on air outlet vent . If unit is running under the high humidity for a long time, the moisture will be condensed on the air outlet grill and drip off. Immediately stop all operations and plug out, contact th...

  • Page 21

    Select a position where the condensing water can be easily drained out, and the place is easily connected for outdoor unit. Can select the place where is strong enough to withstand the full weight and vibration of the unit. And will not increase the noise. Make sure that the indoor unit installation...

  • Page 22

    Notices for installation safety requirements for electric appliances earthing requirements note: make sure that the live wire or zero line as well as the earth wire in the family power socket can not be wrong connected, there should be reliable and no short circuit in the diagram. Wrong connection m...

  • Page 23

    Space to the wall above above installation dimension diagram installation dimension diagram space to the ceiling space to the wall space to the wall air outlet side space to the floor above above above above above the dimensions of the space necessary for correct installation of the appliance includ...

  • Page 24

    Ready your tools ready for the following tools: electric sds drill. (if you use an ordinary drill you will need an sds adaptor) screwdrivers. Posidrive or crosshead prepare hole cutter number 14 (7mm) masonary drill 1.5 inch number 10 screws. Roundhead slotted 7mm wallplugs pipe and cable detector h...

  • Page 25

    Ready your tools ready for the following tools: 2 inch pipe clips circuit breaker when drilling inside and out garden gloves when lifting the outdoor unit dustsheets foam filler silicone sealer and gun.

  • Page 26

    Install indoor unit 1. Check the area for any hidden wires or pipes. 2. Mark the righthand backplate screw position. 3. Remove the backplate and drill a 7mm hole. 4. Tap home a 7mm wallplug. 5. Screw the backplate to the wall using 1.5 inch number 10 screws. 6. Check level, mark the other holes and ...

  • Page 27

    Install indoor unit 13. Undo the power lead and break out the plastic lead tab. 14. Hook the indoor unit onto the top of the backplate. 15. Lock the bottom of the unit onto the base of the backplace. Install the rear panel 1. Always mount the rear panel horizontally. Due to the water tray of indoor ...

  • Page 28: Note:

    Install indoor unit note: ƽ Ł ł install the indoor unit the piping can lead out from left when routing the piping and wiring from the left of the indoor unit, cut off the tailings from the chassis if necessary (show in fig.1) cut off the tailings 1 when routing the wiring only; cut off the tailings ...

  • Page 29

    Install outdoor unit 1. Gently bend the pipe at right angles to the wall. 2. Mark a vericle chalk line on the wall using a spirit level. 3. Mark a chalk line on the floor to line up the outside unit with the connecting cord 4. Mark the four unit fixing holes on the floor. 5. Remove the unit. Drill t...

  • Page 30

    Quick coupling 1. Push the drain hose onto the indoor unit outlet. 2. Remove the raincover from the side (indoor unit). 4. Push the male coupling connector (2) right inside female coupling. 5. Close the retaining clip (4), make sure the fingers of the clip are engaged on the back of the lug. 6. Push...

  • Page 31

    Quick coupling notes: to connect the couplings step 1: ensure that the handle on the male coupling is in a reclined position away from the mating male coupling. Step 2: retract the “release sleeve” on female coupling, insert the male coupling located on the indoor unit into the female coupling. Step...

  • Page 32

    Quick coupling notes: connect indoor and outdoor electric wires 1.Open the surface panel. 2.Remove the wiring cover. 3.Route the power connection cord and signal control wire (for cooling and heating unit only) from the 4.Reassemble the clampand wiring cover. 5.Recover the surface panel. Back of the...

  • Page 33

    Ø condensate drainage of outdoor unit (only for heating) the condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:set the drain connection in 25 hole of the chassis has been installed and then connect drainage pipe...

  • Page 34

    Do not switch on power before installation isfinished completely. Electric wiring must be connected correctly and securely. Switch on power, press "on/off" button on the wireless remote control to start the operation. Check after installation and test operation check after installation items to be c...

  • Page 35: Circuit Diagram

    Circuit diagram indoor unit outdoor unit 33.

  • Page 36

    Fig. A installation instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter 2. Mount the healthy filter onto the air filter,(as shown in fig.B). If the air filter cannot be in- stalled, please mount ...

  • Page 37

    One (1) year limited warranty save this warranty information ecoair guarantees this product free from defects in materials and workmanship for a period of one (1) year from the date of purchase, limited to parts only. Faults arising from a faulty installation is specifically excluded. This unit must...