  • Page 1

    How to install, operate and maintain your central water filtration system model epwhcw central water filtration system manufactured and warranted by ecodyne water systems 1890 woodlane drive woodbury, mn 55125 7339874 (rev. B 8/19/13) if you have any questions or concerns when installing, operating ...

  • Page 2

    2 table of contents page specifications & performance claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 central water filtration system safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 3

    3 specifications & performance claims questions? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or visit www.Ecopurewaterproducts.Com when you call, please be prepared to provide the model and serial number, located on the rating decal on back of the cover. Specifications model epwhcw...

  • Page 4

    4 before you start = do not turn the central water filtration system upside down, drop, or set on sharp protrusions. = the central water filtration system has a maximum allowable inlet water pressure of 125 psi and a minimum of 30 psi. If daytime pressure is over 80 psi, nighttime pressure may excee...

  • Page 5

    How a central water filtration system works normal operation during normal operation water enters the central water filtration system and flows through several fil- tration processes where tastes, odors and sediment are reduced. Clean rinse cycle a clean rinse cycle will automatically be initiated b...

  • Page 6

    6 installation requirements the proper order to install water treatment equipment untreated water to outside faucets fig. 3b hot water to house cold water to house untreated water to outside faucets water heater optional sediment filter pressure tank well pump hot water to house cold water to house ...

  • Page 7

    7 installation requirements plumbing codes all plumbing must be completed in accordance with national, state and local plumbing codes. Valve drain requirements using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check ...

  • Page 8

    8 installation requirements inlet - outlet plumbing options always install either a single bypass valve (provided) to the contractor/plumber-supplied plumbing, as shown in figure 7 or if desired, a 3 valve bypass system (parts not included) can be installed, as shown in figure 6. Bypass valves allow...

  • Page 9

    9 installation instructions turn off water supply 1 . Close the main water supply valve, near the well pump or water meter. 2 . Open all faucets to drain water from the house pipes. Note: be sure not to drain water from the water heater, as damage to the water heater ele- ments could result. Move th...

  • Page 10

    10 1 . Install metal grounding clamp to metal house water supply pipes before beginning installation. 2 . Securely tighten connection in center of metal ground clamp (see figure 10). 3 . Loosely assemble any pipe and fittings needed from the main water supply to the inlet and outlet ports of the cen...

  • Page 11

    11 installation instructions install valve drain hose 1 . Measure, cut to needed length and connect the 3/8" drain line (provided) to the central water filtration system valve drain fitting (see figure 11). Use a hose clamp to hold the hose in place. Note: if codes require a rigid drain line see “va...

  • Page 12

    12 programming the central water filtration system when the transformer is plugged into the electrical outlet, a model code and a test number (example: j2.0), begin to flash in the faceplate display. Then, 12:00 pm and the words “present time" begin to flash. Note: if “- - - -” shows in the display,...

  • Page 13

    13 start up procedure important: run the start up cycle immediately after completing installation, before using any water in the home. The filtration media in this central water filtration system contains a small number of harmless activated carbon particles generated during shipping that are small ...

  • Page 14

    14 customizing features / options set number of days between clean rinse cycles by default the central water filtration system will automatically initiate a clean rinse every 14 days. This should be sufficient for most applications. To change the number of days between clean rinse cycles: 1 . Press ...

  • Page 15

    15 customizing features / options operating in manual clean rinse mode clean rinse cycles will run automatically, unless the automatic clean rinse function has been disabled. If this function has been disabled, it will be necessary to manually initiate any clean rinse cycles. It is recom- mended tha...

  • Page 16

    16 care of your central water filtration system vacations and extended periods of no water use if your central water filtration system will not be used for an extended period of time (several months), please follow one of these recommendations: = if the water supply to the unit is not turned off, an...

  • Page 17

    17 troubleshooting problem cause correction water has black or gray color (new system) start up procedure has not been completed run start up procedure (see page 13) or run consecutive clean rinse cycles (see page 14) until water color returns to normal. (not a new system) normal abra- sion of filtr...

  • Page 18

    18 troubleshooting fig. 25 removing drain fitting to clean flow control clip hose clamp drain hose flow control drain fitting problem cause correction water running to the drain (while unit is not in the clean rinse cycle) inner valve defect causing leak replace seals and rotor filter media in house...

  • Page 19

    19 troubleshooting cleaning the sediment filter screen this procedure is not required if the central water filtration system is operating normally. It should be performed only if a problem with low water pressure at household faucets is encountered, as detailed in the troubleshooting table on page 1...

  • Page 20

    20 central water filtration system exploded view 8 7 11 10 9 12 13 19 16 17 18 22 70 24 valve assembly see pages 22 & 23 for parts 23 20 21 14 15 71 72 72 1 2 4 3 6 5.

  • Page 21

    21 central water filtration system parts list to order repair parts call toll free 1-800-693-1138, monday - friday, 7 am - 6 pm cst. Manufactured and warranted by ecodyne water systems 1890 woodlane drive woodbury, mn 55125 questions? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or ...

  • Page 22

    22 valve assembly exploded view 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 65 74 75 wear strip seal cross-section view 77 78 54 76.

  • Page 23

    23 to order repair parts call toll free 1-800-693-1138, monday - friday, 7 am - 6 pm cst. Manufactured and warranted by ecodyne water systems 1890 woodlane drive woodbury, mn 55125 questions? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or visit www.Ecopurewaterproducts.Com when you...

  • Page 24

    Central water filtration system warranty warrantor: ecodyne water systems, 1890 woodlane drive, woodbury, mn 55125 warrantor guarantees, to the original owner, that: one year full warranty: ● for a period of one (1) year from the date of purchase, all parts will be free from defects in materials and...