Ecor-Pro DH1100 User Manual - page 6
10
11
TECHNICAL DATA
GB
Specifications
DH1100
Typical Extraction @ 32
0
C 90%rh
81 l /day
Typical Extraction @ 30
0
C 80%rh
76 l /day
Typical Extraction @ 30
0
C 70%rh
61 l /day
Air Flow (High Speed)
850 m
3
/hr
Voltage
230 V
Current @ 27
0
C/60%rh
6.5 A
Frequency
50 Hz
Power @ 27
0
C/60%rh
1.65kW
Phase
1ph
Dimensions (mm)
820 x 710 x 360
Weight (NET)
51kg
Weight (GROSS)
53kg
Operating Temperature
7
0
C / 35
0
C
Refrigerant R410A
Hermetically sealed
700g
*
(EC) No 842/2006: R410A is a preparation of fluorinated greenhouse gases covered by the
Kyoto Protocol. Its global warming potential (GWP) is 1725.
Disposal
This marking indicates that this product should not be disposed with other house-
hold wastes throughout the EU.To prevent possible harm to the environment or
human health from uncontrolled waste disposal, recycle it responsibly to promote
the sustainable reuse of material resources. To return your used device, please
use the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
IMPORTANT:
This dehumidifier should not be used in temperatures below 7°C or above
35°C.
Defrost Control
The dehumidifier is equipped with an automatic de-icing mode to defrost
the refrigeration coil during low temperature operation. The compressor is
switched off whilst the fan continues to run.
TROUBLE SHOOTING
If the dehumidifier does not operate:
•
Make sure the unit is plugged in.
•
Ensure the humidistat control is turned on.
If the unit is noisy:
•
Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
•
Check the drainage tube for correct fitting.
•
Check for twists and bends in the drainage tube.
•
Check the drainage tube for a sufficient and continuous downward slope.
•
Check and make sure that the outlet of the drainage pipe is not under the
water level in the drain.
GB