EcoSmart ECO-11 Installation Instructions Manual

Manual is about: ELECTRIC TANKLESS WATER HEATER

Summary of ECO-11

  • Page 1

    Installation instructions ecosmart electric tankless water heater models: eco-6 / eco-8 / eco-11 the most technologically advanced tankless hot water heater in today's market. 99.8% energy-efficient 1 / 17 “no tank, no wait, no comparison”.

  • Page 2

    Important safety information as when installing or operating any high voltage electrical appliance, basic safety precautions must always be followed. Always shut off all power to the ecosmart unit directly at the electrical breaker box before attempting to clean, install, inspect, repair, disassembl...

  • Page 3

    3 / 17 part identification.

  • Page 4

    The ecosmart electric tankless water heater is supplied with 1/2” compression fittings. Do not weld or use paste or use teflon on fittings. Connect the cold water supply line to the right side of the unit ( " cold water inlet” in diagram on page 3). Connect the hot water supply line to the left side...

  • Page 5

    ● the ecosmart electric tankless water heater unit must be installed to independent double pole breakers. ● each ecosmart model comes supplied with the required wires for installation. ● breaker size and wire gauge must meet all applicable local, state, provincial, and national electrical codes for ...

  • Page 6

    Electrical specifications by model # model required breaker max amp draw awg cable eco-6 1x30 amp 28 #8 eco-8 1x40 amp 37 #8 eco-11 1x60 amp 54 #6 verify all voltage & amperage information listed below with the actual label specificiations on your unit, in case of changes or variations. Model kw vol...

  • Page 7

    Wire gauge and breaker size can vary based on a number of factors, including supplied voltage and length of circuit. Check local requirements. Model wire gauge voltage & amperage breaker size eco-6 #8 2-30 amp 110v hot + 1 ground 30 amp double pole eco-8 #8 2-40 amp 110v hot + 1 ground 40 amp double...

  • Page 8

    Power knob: • click the power knob once to turn the unit on. • click the power knob again to turn the unit off. ºc/ ºf conversion: • press the knob for 3 seconds to change the display from ºc/ ºf. Temperature controller knob: • turn the knob clockwise to increase the temperature set on the thermosta...

  • Page 9

    Fax: 305-623-7923 toll free: 877-47-gogreen congratulations on the purchase of your tankless water heater! You have purchased the most technologically-advanced tankless water heater in the market today. Your ecosmart tankless water heater is backed by the industry’s most comprehensive warranty. Your...

  • Page 10

    For the most part, operating your new tankless water heater is very similar to using any traditional water heating system. However, it is very important that you carefully read all of the set-up procedures and operating instructions and tips to ensure the maximum performance and energy savings from ...

  • Page 11

    Moreover, since a tankless water heater eliminates the ongoing thermal losses caused by storing hot water in a tank, you will enjoy significant energy savings over a conventional water heater. When you use hot water in your home with a conventional water heater, you need to mix a considerable volume...

  • Page 12

    Your new electric tankless water heater requires no maintenance. However, to ensure maximum performance of your water heater and to reduce the risk of a water leak, we do recommend the following maintenance: you should inspect the connections on the inlet and outlet of the water heater at least on a...

  • Page 13

    Are you having problems with your water heater? Do not return your heater to your authorized dealer. Please call our customer service dept. Toll free 877-474-6473 or call your authorized dealer for assistance. All units are thoroughly tested before they leave our factory. In rare instances, your uni...

  • Page 14

    Measured at several flow rates to insure that the proper temperature rise specifications are met and that the unit self-regulates with the varying flow rates. The following table represents some of the most common technical support questions we receive. Before calling us, please read thoroughly to s...

  • Page 15

    You need/want hotter water. Thermal loss due to long pipe run. As the hot water from the heater runs through the hot water delivery system to you faucet, some heat will be lost especially if it has long distance to travel or the pipes are cold. This is normal. You can compensate for this by increasi...

  • Page 16

    Or in part. Ecosmart u.S. L.L.C. Will not accept the return of any product without prior written approval from ecosmart service center and the issuance of a return merchandise authorization number clearly marked on the outside packaging of the return shipment. Ecosmart u.S llc will not be liable, un...

  • Page 17

    Approval from ecosmart u.S., llc and the issuance of a return merchandise authorization number clearly marked on the outside packaging of the return shipment. After (30) calendar days from receipt of product there will be no returns or warranty without receipt of warranty registration by ecosmart us...