EcoSmart GWL10US Service Supplement Manual - page 22
41.
(00101001) Temperature Sensor Fault
The temperature sensor is measuring temperatures above 230
°F (110°C.). The fault is probably
due to a short circuit in the sensor line.
Primary Source - Thermistor.
Action - Replace the Thermistor.
43.
(00101011) OOB Switch Fault
The Motor Controller Module has found that the signal returning from the out of balance switch
indicates that the switch is permanently on or the harness to it is disconnected.
Primary Source - Mechanical.
Action
1) Check that the out of balance switch is free to move.
2) Check that no harnesses are blocking switch movement.
3) Check switch operates correctly when activated. Replace switch if suspect.
4) If the out of balance micro switch shows signs of corrosion replace the switch and fit a
condensation kit to the console area.
Secondary Source - Wiring.
Action
Check the harness to the switch is connected correctly. The terminals should be connected to the
normally closed position. If the harness terminals show signs of corrosion then fit a new harness.
Tertiary Source - Motor Controller Module.
Action-Replace Motor Controller Module.
44.
(00101100) Water in Basket during Spin
The Motor Controller has sensed a water level in the basket during spin. A slow pump out rate
due to pump hose or pump partial blockage may cause this.
Primary Source - Pump System.
Action
1) Check that the drain hose is not squashed or kinked.
2) Check length of drain hose and try to reduce length if excessively long. A 39"(1 metre)
extension hose of the same diameter fitted to the existing drain hose is the maximum
allowable length.
3) If basket empty of water, remove the basket from the top and check that it is not blocked.
Also check the hose is not blocked.
4) If basket contains water, attempt to flick start the pump fan while draining to clear water
before servicing as in 3). If unsuccessful then service pump from the top of the machine by
removing the top deck and inner basket.
Secondary Source - Motor Controller Module.
Action - Replace Motor Controller Module.