WARNING
4. INSTALLATION
Ask your installer to install the air-source heat pump water
heating unit. Incorrect installation performed may result in
water leakage, electric shock, or fire.
Unit installed in a complete unsheltered open area is not
allowed.
The unit must be securely fixed and level, or else may result in
noise and vibration.
Make sure that there is
space around the unit.
In places where there is strong wind such as seashore or
hillside, fix the unit in a location protected from the wind.
Carry the unit onto the site
In order to avoid scratch or deformation of the unit surface,
apply guard boards to the contacting surface.
Do not incline the unit more than 45° when moving, and
keep it vertical when installing.
This system is very heavy, it need to be carried by 2 or more
people, otherwise may cause injury or unit damage.
Install the unit.
The circulating air for every unit should be more than 700m
3
/h.
Make sure there is enough installation space.
Outline dimensional drawing(see Fig.4-1,Fig.4-2)
1920 mm
650 mm
Installation with
cover
Different duct connection may result in slightly different system
efficiency
Fig.3-7
Outdoor Installation
190mm
Air inlet and outlet
both connect
with ducts.
Air inlet
Air outlet
A+B≤10m
A
B
Fig.3-8
Installation take
advantage of warmer air source and cooler
air dispensed for other us
Air inlet
Air outlet
190mm
Outdoor water proof cover seperate
the inlet
and outlet air
Duct Description
≥
100mm
Water inlet
&
outlet
Anode & Coil
PTR Valve
Display
Display