EcoSunTec IMAP-1000 Operation Manual

Manual is about: Infrared Moist Air Purifying Space Heater

Summary of IMAP-1000

  • Page 1

    Ecosuntec infrared moist air purifying space heater imap-1000 operation and warranty manual.

  • Page 2: Ecosuntec

    Ecosuntec ecosuntec 3 way heating system infrared moist air purifying space heater imap-1000 congratulations and thank-you for purchasing the ecosuntec infrared moist air purifying space heater. You are now the owner of the world’s most advanced infrared space heater that purifies the air and combin...

  • Page 3: Ecosuntec

    Ecosuntec infrared moist air purifying space heater imap-1000 ecosuntec 3 way heating system operation and warranty manual please read all instructions before using the heater keep this manual for future reference safety precautions……………………………..……1 proper use and handling…………………………..1-2 unpacking..…...

  • Page 4: Important Instructions

    Important instructions safety precautions warning: improper use of this heater could result in the risk of electric shock, fire and possible injury to individuals. Warning: do not open the heater casing or attempt any repairs or service. Any required service (other than filter maintenance on page 10...

  • Page 5

    Do not set heater close to furniture, pillows, bedding, papers, clothes, curtains or flammable items. Do not sit on the heater, put items on the heater, hang things over the heater or cover the air outlet opening. Do not insert anything into the exhaust, ventilation or heater outlet openings. Do not...

  • Page 6

    Unpacking to unpack the box, peel taped seams, fold back the flaps and roll the entire box upside down. Lift the box off the styrofoam packing and heater. Carefully remove styrofoam and all packing materials. Keep the packaging and box for summer storage and/or any transporting needs. Set the unpack...

  • Page 7

    Operation turning the heater on turn the master switch to the on position so it is illuminated. The unit will now operate in the air purification mode only. To turn on the heating mode select the area or room size setting desired-large, medium or small. Wait for the heater to start operating in abou...

  • Page 8

    Remote control operation the remote control requires 2 “aa” batteries installed into the battery compartment on the back of the remote control. To use the remote control, point the remote at the heater and make selections. Make maximum use of the remote control - reduces “wear and tear” of the contr...

  • Page 9

    Humidifier feature- optional feature the heater can be safely and effectively operated without engaging the humidifier. When the water is diminished from the tank the heater will automatically turn off the humidifier component. To use moist heat humidifying feature 1) use caution when handling the h...

  • Page 10

    Indicator symbol will light up and the humidifier will shut off. The heater will automatically switch to dry heat feature when water tank is emptied. To continue to use the moist heat feature, refill the water tank by following steps 1 to 6. See care and cleaning of humidifier unit on pages 11 &12. ...

  • Page 11

    Timer the heater is equipped with a timer feature that will either shut the unit off after a desired amount of time or delay the time for the unit to turn on. Auto shut off with the unit running at the desired temperature, press the timer button to the desired number of hours you would like the heat...

  • Page 12

    Washable lifetime electrostatic air filter system the ecosuntec infrared moist air purifying space heaters come equipped with a lifetime washable filter. The filter needs to be cleaned regularly. To do this, follow these steps: washable lifetime electrostatic air filter system clean the air purifyin...

  • Page 13

    5) allow the filter to air dry completely before reinstalling on to the back of the heater. 6) do not force the filter to dry using any type alternative methods other than drip dry. Let it air dry completely. 7) reinstall the filter on to the back of the unit by pushing it up against the springs the...

  • Page 14

    Humidifier cleaning and maintenance cleaning the water tank 1) make sure the heater is turned off. Allow the heater to cool for at least 10 minutes if necessary. 2) open the cover plate located on the side of the heater; unclip the clip at the bottom of the door to release. Slide the humidifier unit...

  • Page 15

    Cleaning the humidifier filter 1) pull up to release the filter inside the humidifier tray unit. 2) pour a couple drops of mild dish soap into hot water. Soak the humidifier filter in the solution for 30 minutes. Rinse thoroughly with clean water. 3) allow the filter to dry completely before install...

  • Page 16: Trouble Shooting

    Trouble shooting heater does not turn on is the power cord inserted into the outlet? Check the circuit breaker. Is the heater tilted at all? Check and clean the air filter. Blows only slight air is something blocking the air outlet? Check and clean the air filter. Humidifier not working make sure th...

  • Page 17

    Try different placements of the heater to see what works best for your area/room. Avoid placing the heater in drafty areas or near air filtration systems as the warm air will be exhausted quickly. Close the cold air return to prevent the heat being drawn away. Seal drafty cracks around windows or do...

  • Page 18

    Ecosuntec products with valid serial numbers are warranted to the original purchaser only to be free from defects and workmanship for three (3) years. The heat element is warranted for five (5) years. Warranty period begins on date of purchase. If a valid serial number is missing from a product, the...

  • Page 19

    Incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state. For warranty repairs, please contact ecosuntec at 803-319- 4836 or one of our authorized repair ...

  • Page 20

    17 notes.

  • Page 21

    18 notes.

  • Page 22

    19.

  • Page 23

    Warranty card ecosuntec heater warranty registration thank-you for purchasing the ecosuntec infrared moist air purifying space heater 3 way heating system please return this card within 30 days of purchase to activate your warranty. Failure to do so will void your warranty. -------------------------...

  • Page 24

    --------------------------------------------------------------------------------- place stamp here eco sun technologies, llc 100 old cherokee rd. Suite f-155 lexington, sc 29072 ----------------------------------------------------------------------------------------.