Ecoteck Amalfi Instalation Manual - Installation
2
Installation
Dimensions – Amalfi Freestanding
Refer to Safety Test 09/1910 for all clearances to combustible.
Installation Clearances & Specifications
Minimum clearances shown are in millimetres. All Ecoteck fires are tested to AS/NZS2918:2001.
Specifications were correct at time of printing but may alter and those detailed below should be used as
a guide only. Refer to the Installation and Operation Manual supplied with every Ecoteck Pellet Fire or
if in doubt, consult your Nature’s Flame Retailer.
Clearance to Combustibles
Amalfi Pellet Fire
Location
Dimension
(mm)
A
200
B
150
C*
50
D
~200
E
100
F
100
G*
50
H
200
I*
50
J*
25
Internal Flue (Freestanding)
External Flue (Freestanding)
B
C
A
E
D
G
F
B
F
G
E
B
J
H
A
E
J
J
F
B
I
F
E
* from shielded fl ue
Note: AS/NZS 2918 requires a
minimum of 100mm clearance
for any side requiring access.
Note: These are minimum
clearances to combustibles.
Actual installation distances
may be greater.
NOTE: The above clearance to combustibles on the fl ue are only applicable within the fi re envelope. Clearance outside this e.g.at a ceiling / wall thimble reverts
to 25mm as per ARS fl ue test 05/1185. Correct as at January 2012.
590
34
575
1079
1046
34
554
16