ECS DV25IN33L-1 Installation Instructions And Owner's Manual

Manual is about: DIRECT VENT GAS FIREPLACE HEATER

Summary of DV25IN33L-1

  • Page 1

    Page 1 installation instructions and owner’s manual innsbrook fireplace insert direct vent gas fireplace heater model series dv25in33l(n,p)-1 dv33in33l(n,p)-1 dv35in33l(n,p)-1 ul file no. Mh30033 warning: if not installed, operated and main- tained in accordance with the manufacturer’s instructions,...

  • Page 2: Table Of Contents

    23015-6-0408 page 2 table of contents important safety information .................................................................................................3 safety information for users of lp gas .................................................................................4 introduction...

  • Page 3

    23015-6-0408 page 3 do not operate this appliance without glass front panel installed before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid bur...

  • Page 4

    23015-6-0408 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...

  • Page 5: Introduction

    23015-6-0408 page 5 warning: any change to this fireplace or its controls can be dangerous. Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning. Instructions to installer 1. Installer must leave instruction manual w...

  • Page 6: Specifications

    23015-6-0408 page 6 specifications dv25in33l models lp nat input btu/hr maximum 25,000 25,000 btu/hr minimum 17,000 17,000 kwh (maximum) 7.30 7.30 (minimum) 5.00 5.00 orifice #53 (0.0596) #42 (0.0935) air shutter opening full open 1/8” dv33in33l models lp nat input btu/hr maximum 33,000 33,000 btu/hr...

  • Page 7: Fireplace Insert Dimensions

    23015-6-0408 page 7 fireplace insert dimensions figure 1 when planning a fireplace insert installation, it’s necessary to determine: • the vent system configuration to be used. • gas supply piping. • whether optional accessories - devices such as a wall switch or remote control - are desired. • electr...

  • Page 8: Mantle And Trim Clearances

    23015-6-0408 page 8 mantle and trim clearances combustible mantel/trim area 12” 10” 1 3/4” 23” 11” combustible material no greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles. Figure 4 8” minimum clearance to...

  • Page 9: Gas Supply

    23015-6-0408 page 9 figure 5 the gas pipeline can be brought in through the right or left side of the appliance. The insert has a flexline with shutoff valve located on the right side when facing the unit. See figures 5 and 6. Consult the current national fuel gas code, ansi z223.1 can/cga-b149 (.1 ...

  • Page 10: Venting And Installation

    23015-6-0408 page 10 venting and installation 1. Before beginning, remove glass door and log package from unit. Also check to make sure there is no hidden damage to the unit. Take a minute and plan out the gas, venting and elec- trical route. It is best to start with the gas line first, followed by t...

  • Page 11: Venting And Installation

    23015-6-0408 page 11 venting and installation vent system approvals figure 8 shows the vent termination caps and systems approved for use with these models. Approved vent system terminations are labeled for identification. 3-inch diameter listed flexible aluminum or stainless steel gas vent is used fo...

  • Page 12: Venting And Installation

    23015-6-0408 page 12 figure 8 venting and installation rectangular termination cap (dvvk3fv kit) vent clamps intake vent flue exhaust vent optional on/off switch location 10’ minimum 35’ maximum vent clamps note: long extension tube for inlet vent connection. Retainer screws may be installed through...

  • Page 13: Vertical Termination

    23015-6-0408 page 13 vertical through the roof applications the gas fireplace insert has been approved for: a) vertical installations up to 35 feet in height (top of insert to cap). B) two sets of 45 degree elbow offsets (bends in flexvent) within the vertical installation. From 0 to a maximum of 8 f...

  • Page 14

    23015-6-0408 page 14 alternate on/off switch installation wiring the fireplace note: electrical wiring must be installed by a licensed electrician. Caution: disconnect remote controls if you are ab- sent for extended time periods. This will prevent accidental fireplace operation. Installation of alt...

  • Page 15: Surround Panel Installation

    23015-6-0408 page 15 surround panel installation installing the trim surrounds combustible materials must never overlap onto the front face. Warning: when finishing the fireplace insert, never obstruct or modify the air inlet/outlet louvers on the fireplace in- sert in any manner. Note: install surr...

  • Page 16

    23015-6-0408 page 16 blower accessory information the appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current csa c22.1 canadian electrical code. U.S. Installations, follow local codes and the national e...

  • Page 17: Log Placement

    23015-6-0408 page 17 log placement back log left twig right twig right center log right front log left front log left center log figure 18 figure 19 note: center the front two logs on the front log support ledge. Then make sure they are positioned all the way forward and touching the back edges of t...

  • Page 18: Operating Instructions

    23015-6-0408 page 18 operating instructions initial lighting upon completing the gas line or turning the gas valve on after it has been in the “off” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of ...

  • Page 19

    23015-6-0408 page 19 1. Stop! Read the safety information above. 2. Set remote/off/on switch to off. 3. Turn off all electric power to the appliance (if applicable). 4. Lower bottom louver assembly. 5. Push in gas control knob slightly and turn clockwise to "off." note: knob cannot be turned from "p...

  • Page 20: Standing Pilot Wiring

    23015-6-0408 page 20 standing pilot wiring standing pilot wiring diagram for standing pilot ignition wiring appliance requirements warning: do not connect 110-120 vac to the gas control valve or the appliance will malfunction and the valve will be de- stroyed. Optional wall switch position the wall ...

  • Page 21

    23015-6-0408 page 21 with proper installation and maintenance, your new direct vent gas fireplace will provide years of trouble-free service. If you do experience a problem, refer to the trouble shooting guide below. This guide will assist a qualified service person in the diagnosis of problems and t...

  • Page 22

    23015-6-0408 page 22 insert maintenance and service although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance checkup at the beginning of each heating season. Specific guidelines regarding ea...

  • Page 23: Decorative Accessories

    23015-6-0408 page 23 decorative mission louver decorative leaf louver decorative arch louver std louvers 45 deg std contemporary surround cast iron traditional surround bottom cover decorative accessories the following accessory parts can be obtained from your empire comfort systems dealer. If you n...

  • Page 24: Insert Parts View

    23015-6-0408 page 24 insert parts view 1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 17 19 20 21 22 23 24 25 26 27 28 29 30 31 33 34 35 36 37 38 39 40 41 7 12 32 42 43 18 44 45 46 48 47 49.

  • Page 25: Insert Parts List

    23015-6-0408 page 25 insert parts list part number index no. Dv25in33l(n,p) dv33in33l(n,p) dv35in33l(n,p) description 1 22950 22950 22950 guide, flue connector 2 23309 23211 23211 vent slide plate assembly 3 r9188 r9188 r9188 gasket, top 4 r9192 r9196 r9199 brick panel, back 5 r9195 r9198 r9201 bric...

  • Page 26: How To Order Repair Parts

    23015-6-0408 page 26 parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the parts list have a part number. When or...

  • Page 27: Service Notes

    23015-6-0408 page 27 service notes.

  • Page 28: Empire

    23015-6-0408 page 28 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...