Edco VAC-200 Operator's Instruction Manual - Vac-200
Printed in USA
©2008
TVW
Page 10
100 Thomas Johnson Drive, Frederick, MD 21702-4600 USA
Phone (301) 663-1600 • 1-800-638-3326
Fax (301) 663-1607 • 1-800-447-3326
Website: www.edcoinc.com
Email: sales@edcoinc.com
E-VAC290&VAC200-I-0808
VAC-200
Motor Brushes Inspection
1. Turn the machine off then disconnect the power source.
2. Remove the motor deck socket truss screws.
3. Remove the silencer hood assembly.
4. Remove the 4 metal motor-cap retaining clips using a standard bit screwdriver.
5. Carefully dislodge the plastic motor cap via the built in hooks on both sides of each motor brush using a standard
screwdriver. (TIP: Dislodge one side of a cap fi rst, then the other.)
6. Remove the motor brush retainers via the 2 phillips screws per brush.
7. Remove each of the brushes and inspect for excessive or uneven wear.
NOTE: A brush should be replaced if its length is less than 0.25 inches.
8. Reverse the procedure to install each brush.
9. Replace the silencer hood; make sure the switch mount is fi t into the slot in the silencer hood.
10. Secure the silencer hood with the 4 socket truss screws.