Installation
: Fixed installation
Over Voltage Category
: II
Pollution Degree
: II, office or workplace, none conductive pollution
Operating Conditions
: Continuous
Supply Voltage and Power
: 230 V V (-%15 / +%10) 50/60 Hz. 2.3VA
115 V V (-%15 / +%10) 50/60 Hz. 2.3VA
24 V V (-%15 / +%10) 50/60 Hz. 2.3VA
24 V Z (-%15 / +%10) - 4W
Digital Inputs
Electrical Characteristics
: Rated voltage : 16 VZ @ 5mA
Maximum continuous permissible voltage : 30 VZ
Logic 1 minimum level : 3 VZ
Logic 0 maximum level : 2 VZ
Sensor Supply Voltage
: 12VZ
± %40 maximum 50mA
Maximum Input Frequency
: = 0 , 1 , 2 with 20000 Hz
= 3 , 4 with 20000 Hz
= 5 , 6 with 12000 Hz
= 7 with 10000 Hz
Output Type
: Relay Output 5A@250VV Resistive Load
100.000 operation (Full Load)
Actual Value Display
: 8 mm Red 6 digit LED Display
Set Display
: 8 mm Green 6 digit LED Display
LED Displays
: SV (Set value) , OP (Control output) LEDs
Approvals
: ,
8. Other Informations
Manufacturer Information:
Emko Elektronik Sanayi ve Ticaret A.Þ.
Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No:6 16369
BURSA/TURKEY
Phone : +90 224 261 1900
Fax : +90 224 261 1912
Repair and Maintenance Service Information:
Emko Elektronik Sanayi ve Ticaret A.Þ.
Demirtaþ Organize Sanayi Bölgesi Karanfil Sk. No:6 16369
BURSA/TURKEY
Thank you very much for your preference to use Emko Elektronik
Products.
Your Technology Partner
www.emkoelektronik.com.tr
Summary of EZM-4430
Page 1
E z m -4 4 3 0 4 8 x 4 8 d in 1 /1 6 p ro g ra m m a b le c o u n te r ezm-4430 48 x 48 din 1/16 universal input programmable counter introduction manual. Eng ezm-4430 02 v03 08/14 - - - 6 digits process (pv) and 6 digits set (sv) value display - operation with 1 set value - reset , pause and cha-ch...
Page 2
2 a c i instruction manual of ezm-4430 programmable counter consists of two main sections. Explanation of these sections are below. Also, there are other sections which include order information and technical specifications of the device. All titles and page numbers in instruction manual are in “con...
Page 3
3 1.Preface.................................................................................................................. 1.1 general specifications 1.2 ordering information 1.3 warranty 1.4 maintenance 2.Installation..................................................................................
Page 4
4 manufacturer’s name : emko elektronik a.S. Manufacturer’s address : dosab, karanfil sk., no:6, 16369 bursa, turkey the manufacturer hereby declares that the product: product name : programmable counter type number : ezm-4430 product category : electrical equipment for measurement, control and labo...
Page 5: Ezm-4430
5 1.Preface 1.1 general specifications application fields package machines, quality control rollers, filling systems, measuring dimension and control automation, in cutting and processing machine of glass, plastic, marble, sheet, iron and fabric building automation. Production bands tool benchs, ezm...
Page 6
6 1.2 ordering information e z m-4430 ( 48x48 din 1/16) a bc d e fg hi / / u v w z / / all order information of ezm-4430 programmable counter are given on the table at left. User may form appropriate device configuration from information and codes that at the table and convert it to the ordering cod...
Page 7
7 in package , - one piece unit - two pieces mounting clamps - one piece instruction manual a visual inspection of this product for possible damage occured during shipment is recommended before installation. It is your responsibility to ensure that qualified mechanical and electrical technicians ins...
Page 8
2.1 general description 2.2 dimensions 8 4 8 m m / 1 .8 9 i n c h 48 mm / 1.89 inch 11.1 ± 1 mm / 0.43 inch op o2 sv s2 ezm-4430 reset counter p set mounting clamp device label op o2 sv s2 - 43 ezm 4 0 r set e counte r p set 84 mm / 3.31 inch maximum 5 mm / 0.2 inch front panel ip65 protection panel...
Page 9
2.3 panel cut-out 9 6 5 m m / 2 .5 6 i n c h ( m in ) 65 mm / 2.56 inch (min) 46 mm / 1.81 inch (min) 4 6 m m / 1 .8 1 i n c h ( m in ).
Page 10
C 10 1 2 3 op o2 sv 2 s -4 ezm 430 r se e t u e co nt r p et s operating temperature : 0 to 50 °c max. Operating humidity : 90% rh (non-condensing) altitude : up to 2000m. Operating conditions forbidden conditions: corrosive atmosphere explosive atmosphere home applications (the unit is only for ind...
Page 11
C c 11 p o o2 v s s2 e m z -443 0 r s t e e counte r p e s t op o2 sv s2 z -44 0 e m 3 eset r c nt r ou e p e s t 2.6 installation fixing clamp 2.7 removing from the panel montage of the unit to a system must be done with it’s own fixing clamps. Do not do the montage of the device with inappropriate...
Page 12
12 a a torque 0,5nm max. 2.5mm / 0.098 inch wire size: 14awg/1mm² solid / stranded screw driver 0,8 x3mm 3.1 terminal layout and connection instructions you must ensure that the device is correctly configured for your application. Incorrect configuration could result in damage to the process being c...
Page 13: 10 11 12 13
13 count inputs m a x 5 0 m a c h a c h b p a u s e r e s e t sensor supply voltage 1 2 v z 0 v z supply voltage output (it must be determined in order.) 230v v (-%15;+%10) 50/60hz - 2.3va 115v v (-%15;+%10) 50/60hz - 2.3va 24 v v (-%15;+%10) 50/60hz - 2.3va 24 v z (-%15 / +%10) - 4w relay output a ...
Page 14
3.3 view of device label p/n : ezm-4430 n l 5a@250vv y c a 7 6 5 4 3 2 1 nc no c 230v v -%15;+%10 50/60hz -1.5va 1 2 v z m a x .5 0 m a 0 v z c h -a c h -b p a u s e r e s e t 14 13 12 11 10 9 8 14.
Page 15
15 3.4 connection of device supply voltage input note-1 : there is internal 33 r w fusible 115v v 50/60 hz and 230vv 50/60 hz there is internal 4r7 w fusible 24v v 50/60hz flameproof resistor in flameproof resistor in supply voltage 115vv, 230 v v (-%15;+%10) 50/60 hz 13 n l 14 y power supply switch...
Page 16
16 1 4 2 5 3 6 0 v z c h a c h b p a u s e prox. Prox. R e s e t npn npn 1 4 2 5 3 6 1 2 v z m a x . 5 0 m a 0 v z c h a c h b p a u s e s w it c h prox. Prox. S w it c h r e s e t note-1 pnp pnp 1 2 v z m a x . 5 0 m a note-1 s w it c h s w it c h 3.5.1 proximity & switch connection 3.5 counting in...
Page 17
17 1 4 2 5 3 6 c h a c h b p a u s e incremental encoder 10 to 30v z r e s e t 1 4 2 5 3 6 c h a c h b p a u s e incremental encoder 10 to 30v z r e s e t s w it c h s w it c h note-1 s w it c h s w it c h note-1 0 v z 1 2 v z m a x . 5 0 m a 0 v z 1 2 v z m a x . 5 0 m a 3.5.2 incremental encoder &...
Page 18
18 1 4 2 5 3 6 c h a c h b p a u s e r e s e t s w it c h s w it c h 1 4 2 5 3 6 c h a c h b p a u s e r e s e t s w it c h s w it c h note-1 s w it c h s w it c h s w it c h s w it c h note-1 0 v z 1 2 v z m a x . 5 0 m a 0 v z 1 2 v z m a x . 5 0 m a 3.5.3 switch connection = = pnp type operation ...
Page 19: L N
19 2 13 14 2000v v 2000v v 4 5 4 5 1 1 0 v z 3 3 6 6 2000v v 10 11 12 c 11 10 12 l n c c nc no 10 11 12 2000v v supply voltage 500v v ( for ezm-4430.3 ) 2000v v ( for ezm-4430.5 ) 12v z sensor supply voltage digital inputs relay outout 3.6 relay output wiring diagram fuse load last control element (...
Page 20
20 op o2 sv s2 ezm-4430 reset counter p set displays actual value and name of program parameter displays set and parameter value prog button is used for accessing to the program parameters led indication of set value led indication of output is active reset and increment button is used to reset the ...
Page 21
21 c o1 o2 sv s2 ezm-4430 counter o1 o2 sv s2 ezm-4430 counter op o2 sv s2 ezm-4430 reset counter p set reset p set reset p set revision number 4.2 power on observation of ezm - 4430 programmable counter and software revision on the display when power on, view of the screen is shown below: when powe...
Page 22
22 4.3 adjustment of set value changing set value o1 o2 sv s2 counter o1 o2 sv s2 counter reset p set reset p set operation screen set screen when shift button is pressed, 6th digit of set value starts to flash. Press shift button again. Increase the flashing value with increment button. Press shift...
Page 23
23 i 4.4 resetting the count value when reset button is pressed, actual value becomes the reset-offset value. Reset operation can be realized by reset button or applying signal to the reset input. These two operations are named manual reset in parameters section. At the end of manuel reset operation...
Page 24
24 o1 o2 sv s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter reset p set o1 o2 s1 s2 counter reset p set reset p set o1 o2 s1 s2 counter reset p set reset p set when prog button is pressed, password must be entered to access the program parameters enter password with shift and increment button ope...
Page 25
25 o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter reset p set reset p set reset p set reset p set filter time for reset and pause input you can change the p a r a m e t e r w i t h increment button, save it to the memory and p a s s t o t h e n e x t parameter with e...
Page 26
26 o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter reset p set reset p set reset p set reset p set output run type output pulse time point position data record you can change the p a r a m e t e r w i t h increment button, save it to the memory and p a s s t o t h e n...
Page 27
O1 o2 s1 s2 counter 27 o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter reset p set reset p set reset p set reset p set reset and set protection multiplication coefficient reset offset program password you can change the p a r a m e t e r w i t h increment button, save it to the memory an...
Page 28
28 o1 o2 s1 s2 counter o1 o2 sv s2 counter reset p set reset p set continue to press enter button for scanning all parameters. Input types and functions operation screen.
Page 29
Input types and functions 29 8. Parametreler 5. Program parameters upcount on rising edge of ch-a input downcount on rising edge of ch-a input. Value on the screen start value = 0 start value = 8 upcount on rising edge of ch-a input. Downcount on rising edge of ch-b input. Start value = 0 start valu...
Page 30
30 upcount on rising edge of ch-a input upcount on rising edge of ch-b input start value = 0 start value = 8 counting to upwards counting to downwards value on the screen upcount on rising edge of ch-a input when ch-b is at 0 downcount on rising edge of ch-a when ch-b is at 1 ch-a start value = 0 ch...
Page 31
31 x2 phase shifting (for incremental encoders) upcount on rising edge of ch-a when ch-b is at 0 downcount on rising edge of ch-a when ch-b is at 1 upcount on falling edge of ch-a when ch-b is at 1 downcount on falling edge of ch-a when ch-b is at 0 x4 phase shifting (for incremental encoders) upcou...
Page 32
32 direction of counting upcount. ( 0 --> preset ) downcount. ( preset --> 0 ) input types and functions parameter is or then direction of counting parameter can not be accessed. I if input types and functions parameter; is entered , or then, pulse time for ch-a and ch-b input parameter can not be a...
Page 33
33 manual reset-1. Device continues to count till manual reset is applied. (output pulsetime is not considered) output functions count direction : 0 --> p (upcounting) 0 output set reset = counting direction : p --> 0 (downcounting) 0 reset offset reset output = when count value reaches the 0, outpu...
Page 34
34 counting direction : 0 --> p (upcounting) = 0 set reset output manual reset-2. (output pulse time is not considered) when count value reaches the set value, output position is changed. Counting process is not continue over the set value. Output pulse time is not considered. Process counts, until ...
Page 35
= = counting direction : 0 --> p (upcounting) = 35 0 set reset output output manual reset-3. Device continues to count till manual reset is applied. (output pulse time is considered.) when count value reaches the set value, output position is changed. If output pulse time is not 0, then output posit...
Page 36
36 automatic reset-1 counting direction : 0 --> p (upcounting) = 0 set reset output output = = when count value reaches the set value, output position is changed. Actual value is reset automatically. Counting starts upcounting from 0 value. If output pulse time is not 0, then output position is chan...
Page 37
37 counting direction : 0 --> p (upcounting) = automatic reset-2 0 set reset output 0 set reset output = = when count value reaches the set value, output position is changed. If output pulse time is not 0, then output position is changed the old position at the end of the pulse time. Actual value is...
Page 38
38 counting direction : p --> 0 (downcounting) = 0 set reset output 0 set reset output = = reset offset reset offset = = when count value reaches the 0 value, output position is changed. If output pulse time is not 0, then output position is changed the old position at the end of the pulse time. Act...
Page 39
When count value reaches the set value, output position is changed. If output pulse time is not 0, then output position is changed the old position at the end of the pulse time. Count value starts counting from 0 value. But set value is observed in actual value display. Real counting value is shown ...
Page 40
40 counting direction : p --> 0 (downcounting) = 0 set reset output 0 set reset output = = reset offset reset offset when count value reaches the 0 value, output position is changed. If output pulse time is not 0, then output position is changed the old position at the end of the pulse time. Count v...
Page 41
When count value reaches the set value, output position is changed. If output pulse time is not 0, then output position is changed at the end of the pulse time. Counting continue over set value. Counting value becomes 0 and output position becomes old position. If output pulse time ,then output posi...
Page 42
42 counting direction : p --> 0 (downcounting) = 0 set reset output = 0 set reset output reset offset reset offset = when count value reaches the 0 value, output position is changed. If output pulse time is not 0, then output position is changed at the end of the pulse time. Counting continue under ...
Page 43
43 0 set reset output or 0 set reset output or automatic reset-5 is not considered. If count value is equal or less than value, then output becomes active. If count value greater than v a l u e , t h e n output becomes inactive. Output pulse time is not considered. When manual reset happens; if , th...
Page 44
44 output run type output normally non-energised output normally energised output pulse time it determines how long output will be active. It can be adjusted from 00.00 to 99.99 seconds. If it is 00.00 second, then it operates indefinitely. For details, refer to the section where output functions ar...
Page 45
45 multiplication coefficient reset offset it can be adjusted from to . For details, refer to the output functions section. It can be adjusted from to . Changes in this parameter is evaluated when counting starts. If it is multiplication is not performed. So number of pulses are displayed without ha...
Page 46
46 o1 o2 sv s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter o1 o2 s1 s2 counter reset p set reset p set reset p set reset p set 6. Failure messages in ezm-4430 programmable counter 1- if the password is not 0, user can access to the parameters without entering the password and by pressing enter b...
Page 47
O1 o2 s1 s2 counter o1 o2 sv s2 counter ov o2 sv s2 counter ov o2 sv s2 counter 47 reset p set reset p set reset p set reset p set input types and functions operation screen 3- if actual value is flashing and counting is stopped ; it appears if any of the count value is lower than the minimum count ...
Page 48
48 installation : fixed installation over voltage category : ii pollution degree : ii, office or workplace, none conductive pollution operating conditions : continuous supply voltage and power : 230 v v (-%15 / +%10) 50/60 hz. 2.3va 115 v v (-%15 / +%10) 50/60 hz. 2.3va 24 v v (-%15 / +%10) 50/60 hz...