Empire AW-40-1SPP Installation Instructions Manual

Manual is about: FAN TYPE VENTED WALL FURNACE

Summary of AW-40-1SPP

  • Page 1

    12427-5-0806 page 1 installation instructions and owner's manual fan type vented wall furnace model faw-40-1spp faw-40-1ip effective date august 2006 warning: if not installed, operated and maintained in accordance with the manu- facturer's instructions, this product could expose you to substances i...

  • Page 2

    12427-5-0806 page 2 the base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile. Installation in residential garages gas utilization equipment in residential garages shall be installed so that all burn...

  • Page 3

    12427-5-0806 page 3 some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability t...

  • Page 4

    12427-5-0806 page 4 furnace opening confined space figure 1 outdoor air outlet and inlet air can be brought into the confined space via openings into a ventilated attic and ventilated crawl space. Furna ce outle t air inle t a ir a ttic ve ntila tion louvers cra wl space ve ntila tion louvers figure...

  • Page 5

    12427-5-0806 page 5 c. 4" (102mm) oval in-the-wall (all parts purchase locally) 1. Type b-1 oval pipe or b-w vent pipe 2. Type b-1 oval elbows or b-w oval elbows 3. Single story type b-1 or (b-w) gas vents require a baseplate and one pair of ceiling plate spacers. 4. Multi-story type b-1 or (b-w) ga...

  • Page 6

    12427-5-0806 page 6 figure 5 use u.L. Listed gas vent equipment when installing the faw-40. For vent pipe running through walls, roof, and within one (1) inch (25mm) of combustible construction, use b-1 or (b-w) [one inch (25mm) clearance to combustibles] vent pipe. Type b-2 x 4 or type b-2 x 6 are ...

  • Page 7

    12427-5-0806 page 7 #8 x 3/8" (9mm) screws provided. 8. Align clearance holes on 6" x 10" (152mm x 254mm) duct with screw holes on inner casing back and mark duct to be 2 1/4" (57mm) shorter than 8" x 12" (203mm x 305mm) boot. Remove duct and cut to proper length. 9. Attach 6" x 10" (152mm x 254mm) ...

  • Page 8

    12427-5-0806 page 8 attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.C.) (3.5 kpa) on the appliance gas valve, it will result in a hazardous condition. Checking manifold pressure both propane and natural gas valves have a built-in pressure regulator in the ...

  • Page 9

    12427-5-0806 page 9 oiling the motor the fan motor should be cleaned and oiled once each heating season. Oil holes are located on the top at each end of the motor. Use a few drops of #10 motor oil. To clean the motor, blow air through its ventilation openings with a vacuum cleaner or low pressure ai...

  • Page 10

    12427-5-0806 page 10 service and maintenance suggestions call serviceman general: all furnaces have been fire-tested to check for proper op- eration. This includes, main burner flame, pilot flame, fan operation, fan control, limit control and automatic valve operation. If the furnace fails to function ...

  • Page 11: Lighting Instructions

    12427-5-0806 page 11 for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow the...

  • Page 12: Operating Instructions

    12427-5-0806 page 12 for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do ...

  • Page 13: Sequence Of Operation

    12427-5-0806 page 13 start system check trial for ignition main burner operation end pilot valve opens ignitor powered flame signal detected thermostat calls for heat ignitor off main valve opens internal check ok pilot light and flame is sensed during trial for ignition (1) apply 24 vac to applianc...

  • Page 14

    12427-5-0806 page 14 start ip system troubleshooting sequence turn off gas supply disconnect system control harness set thermostat to call for heat check for proper voltage at control harness (see inseta- voltage should be 24v between thermostat and 24v common, and 24v between 24vcommon and 24vhot.)...

  • Page 15

    12427-5-0806 page 15 index part no. Number description index part no. Number description please note: when ordering parts, it is very important that part number and description of part coincide. 1 wfa-115 gasket - header 2 dv-1247 top plate (usa) 2 15668 top plate (canada) 3 r-3165 door clip (2 requ...

  • Page 16

    12427-5-0806 page 16.

  • Page 17: Service Notes

    12427-5-0806 page 17 service notes.

  • Page 18