Empire BF-10-1 Installation Instructions And Owner's Manual

Summary of BF-10-1

  • Page 1

    R-4973 page 1 warning: if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — what to do...

  • Page 2

    Page 2 r-4973 introduction always consult your local building department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater. This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by ...

  • Page 3

    R-4973 page 3 by point with the members of your household. Someday when there may not be a minute to lose, everyone's safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more informa- tion, please contact your gas supplier. Propane (...

  • Page 4

    Page 4 r-4973 c. Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, be- tween wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings. If the heater is installed in a...

  • Page 5

    R-4973 page 5 attention: optional srs-18 and srs-30 floor stand meets re- quirement. The base referred to above does not mean the fire-proof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile. Figure 4 gas supply (figure 4) check all local codes f...

  • Page 6

    Page 6 r-4973 pressure testing of the gas supply system 1. To check the inlet pressure to the gas valve, a 1/8" (3mm) n.P.T. Plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. 2. The appliance and its appliance ma...

  • Page 7

    R-4973 page 7 attention: bf-10-1, natural or propane gas has a front and rear air shutter. Bf-20-1, propane gas only has a front air shutter. Bf-30-1, propane gas only has a front air shutter. Air shutter adjustment (figure 7) the air shutter on main burner is factory set at a 3/32" opening. If yell...

  • Page 8: Lighting Instructions

    Page 8 r-4973 for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these ins...

  • Page 9

    R-4973 page 9 1. Spark electrode does not produce spark. A. Spark electrode broken - replace. B. Ignitor wire may not be attached to spark electrode - attach. C. Ignitor wire damaged - replace. D. Piezo ignitor defective - replace. 2. Spark electrode produces spark but pilot does not light. A. No ga...

  • Page 10

    Page 10 r-4973 empire comfort systems, inc. Nine eighteen freeburg ave. Belleville, il 62222-0529 how to order repair parts... Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be ship...

  • Page 11

    R-4973 page 11 installing optional blower srb-18t or srb-30t if heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on srs-18 or srs-30 optional floor stand there is adequate access area available to install the...

  • Page 12

    Page 12 r-4973 . ... Parts list wiring the appliance, when installed, must be electrically grounded in accor- dance with local codes or, in the absence of local codes, with the national electrical code, ansi/nfpa 70, if an external electrical source is utilized. This appliance is equipped with a thr...