Empire Comfort Systems DV-55E-5 Installation Instructions And Owner's Manual

Manual is about: FAN TYPE Direct Vent Wall Furnace

Summary of DV-55E-5

  • Page 1

    Page 1 installation instructions and owner's manual fan type direct vent wall furnace for installation in manufactured (mobile home), modular or residential homes model dv-55e-5 warning: if not installed, operated and maintained in accordance with the manufactur- er's instructions, this product coul...

  • Page 2: Table Of Contents

    19563-4-0610 page 2 section page important safety information ......................................................................................................................3 safety information for users of lp gas ..................................................................................

  • Page 3

    19563-4-0610 page 3 • due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young children should b...

  • Page 4

    19563-4-0610 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...

  • Page 5

    19563-4-0610 page 5 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust ve...

  • Page 6: Introduction

    19563-4-0610 page 6 introduction always consult your local building department regarding regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to installer 1. Installer must leave instruction manual with owner after installation. 2. Installer mu...

  • Page 7: Gas Supply

    19563-4-0610 page 7 consult the current national fuel gas code, ansi z223.1 can/ cga-b149 (.1 or .2) installation code. Recommended gas pipe diameter pipe length schedule 40 pipe inside diameter tubing, type l outside diameter nat. L.P. Nat. L.P. 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7...

  • Page 8: Gas Conversion Instructions

    19563-4-0610 page 8 warning: conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit....

  • Page 9: Clearances

    19563-4-0610 page 9 1. Pick a location on a wall with a clear space of 36" (91.4cm) high by 43" (109cm) wide in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close eno...

  • Page 10

    19563-4-0610 page 10 figure 4 installing wall bracket (figures 5 and 6) after finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the wall. Use the (2) 10 x 1 ...

  • Page 11

    19563-4-0610 page 11 venting (figures 7 and 8) this unit is vented directly out the back using the concentric vent tube assembly provided. See figure 2 for vent hole location. This hole location can be conveniently moved closer to unit exhaust outlet tube to avoid wall stud interference if necessary...

  • Page 12: Lighting Instructions

    19563-4-0610 page 12 for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automati...

  • Page 13: Wiring

    19563-4-0610 page 13 the appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the national electrical code, ansi/nfpa 70 or canadian electrical code, csa c22.1, if an external electrical source is utilized. This appliance is ...

  • Page 14: Maintenance

    19563-4-0610 page 14 proper main burner flame the proper main burner flame will be a blue primary (inner) flame with a larger, lighter blue secondary (outer) blue flame. Figure 10 cleaning main burner(s) remove main burner(s) and apply air pressure inside the throat and ports of the main burner(s). ...

  • Page 15

    19563-4-0610 page 15 your new furnace should provide many years of trouble free performance, however, a yearly inspection of the burners , flue passageways and the outlet vent assembly should be done. Be sure all passageways are open and clear of any obstruction, or soot build up. Be sure to shut of...

  • Page 16

    19563-4-0610 page 16 furnace control board diagnostics fault sequence code — trouble shooting guide # of blinks fault condition fault correction steady on control ok 1 flash temperature limit switch is open -check circulating air blower inlet or grill outlet for blockage, inducer blower/circulating ...

  • Page 17: How To Order Repair Parts

    19563-4-0610 page 17 parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the parts list have a part number. When ord...

  • Page 18: Parts View

    19563-4-0610 page 18 parts view.

  • Page 19: Service Notes

    19563-4-0610 page 19 service notes.

  • Page 20: Empire

    19563-4-0610 page 20 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...

  • Page 21

    Page 1 instructions pour l'installation et manuel du propriÉtaire radiateur mural À circulation forcÉe avec un Évent direct pour l’installation dans des maisons prÉ-fabriquÉes (maison mobile), modulaires ou rÉsidentielles modÈles dv-55e-5 brevet # 5.664.555 cet appareil doit être installé selon une ...

  • Page 22

    19563-2-0907 page 2 section page information importante de sécurité ............................................................................................................ 3 information de sécurité pour les utilisateurs de propane ...................................................................

  • Page 23

    19563-2-0907 page 3 • a cause des hautes températures, cet appareil doit être situé dans un endroit non achalandé et loin des meubles et des rideaux. • les enfants et les adultes doivent être avisés des dangers des parois très chaudes et doivent rester loin pour éviter les brûlures ou l'allumage des...

  • Page 24

    19563-2-0907 page 4 il y a des personnes qui ne peuvent pas sentir très bien. Il y a des personnes qui ne peuvent pas sentir l'odeur chimique mis dans le gaz. Vous devez vérifier si vous pouvez sentir cette odeur. Fumer peut décroître votre capacité de sentir. Sentir une odeur pour un certain temps,...

  • Page 25

    19563-2-0907 page 5 introduction introduction toujours consulter le département de construction de votre région en ce qui regarde les règlements, les codes ou les ordonnances qui s'appliquent à l'installation d'un radiateur mural à évacuation directe. Instructions pour l'installateur 1. Après l'inst...

  • Page 26

    19563-2-0907 page 6 consulter le code d’installation en cours du national fuel gas code, ansi z223.1 can/cga-b149 (.1 ou .2). Le diamètre recommandé de tuyau de gaz longuer de tuyau le plan 40 tuyau diameter d’intérieur les tuyaux, taper l hor du diamétre nat. Lp nat. Lp 0-10 feet 0-3 meters 1/2” 2....

  • Page 27

    19563-2-0907 page 7 attention: conversion doit être faite par un technicien d'entretien qualifié. Les orifices du brûleur principal et la nouvelle étiquette pour le changement des gaz sont fournis dans l'ensemble de conversion qui est attaché au tuyau de gaz. Les instructions pour la conversion du g...

  • Page 28

    19563-2-0907 page 8 clearances 1. Choisissez un endroit sur un mur qui aura un espace libre de 36” (91.4cm) de haut par 43” (109cm) de large. En choisissant un emplacement, il est nécessaire de fournir l'espace libre adéquat pour l'accès à l'installation et à l'entretien. Pour une adéquate alimentat...

  • Page 29

    19563-2-0907 page 9 figure 4 installation du support mural (figures 5 and 6) après avoir trouver l'emplacement du radiateur, l'alimentation de gaz et l'évent, le support mural doit être placé et installé. Le support doit être attaché aux montants du mur, si possible, ou accroché solidement au mur. U...

  • Page 30

    19563-2-0907 page 10 Évacuation (figures 7 and 8) l'évacuation des gaz de cet appareil est faite directement à l'arrière en utilisant un ensemble de tuyau d'évent concentrique, fourni avec l'appareil. Voir figure 2 pour l'emplacement du trou d'évacuation. Si nécessaire, l'emplacement du trou peut êt...

  • Page 31

    19563-2-0907 page 11 pour votre sÉcuritÉ, lire avant d'allumer avertissement: si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages À la propriÉtÉ, des blessures corporelles ou la mort. A. Cet appareil n’a pas de veilleuse. Il est muni d’un ...

  • Page 32

    19563-2-0907 page 12 si vous utilisez une source électrique extérieure, l'appareil, lorsqu'il est installé, doit avoir une prise de terre conforme avec les codes locaux ou dans l'absence de codes locaux, avec le national electrical code, ansi/nfpa70 ou canadian electrical code, csa c22.1. Pour votre...

  • Page 33

    19563-2-0907 page 13 aspect convenable de la flamme du brûleur principal la flamme convenable pour le brûleur principal consistera d'une flamme (intérieure) primaire bleue avec une flamme secondaire (extérieure) plus large et d'un bleu plus pâle. Tuyau de l'Échangeur flamme primaire brÛleur flamme s...

  • Page 34

    19563-2-0907 page 14 fonctionnement et dÉtection des dÉfectuositÉs votre nouveau radiateur vous apportera plusieurs années de performance sans trouble, par contre, une inspection annuelle des brûleurs, des tuyaux d'évacuation et l'ensemble d'évent extérieur doit être faite. Soyez certain que tous le...

  • Page 35

    19563-2-0907 page 15 diagnostic du circuit de commande de chaudiÈre code d’erreur sÉquentiel — guide de dÉpannage clignotements État d’erreur correction de l’erreur allumé en continu commande ok 1 clignotement le rupteur thermique est ouvert -vérifier l’absence d’obstruction de l’admission ou la gri...

  • Page 36

    19563-2-0907 page 16 index part no. Number description index part no. Number description numéro d’index numéro de la pièce description 1 dv-1378 blindage du dessus 2 dv-1376 blindage du côté droit 3 r-2521 filtre à air 4 dv-1375 support pour filtre 5 dv-1379 support de montage mural 6 dv-1048 suppor...

  • Page 37

    19563-2-0907 page 17 vue des piÈces.

  • Page 38

    19563-2-0907 page 18 notes de service.

  • Page 39

    19563-2-0907 page 19 notes de service.

  • Page 40: Www.Empirecomfort.Com

    19563-2-0907 page 20 empire comfort systems, inc. 918 freeburg ave. Belleville, il 62220 ph: 618-233-7420 or 800-851-3153 fax: 618-233-7097 or 800-443-8648 info@empirecomfort.Com www.Empirecomfort.Com.