    R-3122 page 1 installation instructions and owner's manual fan type direct vent wall furnace model dvc-35-1spp dvc-35-1ip effective date august, 2000 warning: if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of...

  • Page 2

    Page 2 r-3122 this is a heating appliance do not operate this appliance without front panels installed . • due to high temperatures the appliance should be lo- cated out of traffic and away from furniture and draper- ies. • children and adults should be alerted to the hazards of high surface tempera...

  • Page 3

    R-3122 page 3 some people cannot smell well. Some people cannot smell the odor of the chemical stench put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to det...

  • Page 4

    Page 4 r-3122 qualified installing agency installation and replacement of gas piping, gas utilization equip- ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which e...

  • Page 5

    R-3122 page 5 locating gas supply the gas line can enter the furnace either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Locating electric su...

  • Page 6

    Page 6 r-3122 3. Attach 6" (152mm) diameter air inlet tube onto the collar of air drop assembly. Attach caulked, outside mounting plate into the 6" (152mm) diameter air inlet tube. Position the outside mount- ing plate so that 6" (152mm) diameter air inlet tube has a slight downward slope to the out...

  • Page 7

    R-3122 page 7 gas supply check all local codes for requirements, especially for the size and type of gas supply line required. On natural gas lines less than 75' (23m) long, use 1/2" (13mm) pipe; on longer runs, use 3/4" (19mm) iron pipe or equal. On lp gas lines please consult lp gas supplier. Inst...

  • Page 8

    Page 8 r-3122 spark electrode thermocouple pilot burner standing pilot pilot location end view pilot shield thermocouple spark electrode standing pilot shown burner pilot hot surface ignitor flame rod ground electrode 3/8" to 1/2" pilot flame ip-model pilot figure 9 proper main burner flame the corr...

  • Page 9

    R-3122 page 9 figure 11 burner box gas valve junction box- transformer limit switch fan switch fan piezo ignitor figure 12.

  • Page 10

    Page 10 r-3122 caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangeros operation. Verify proper operation after servicing. Ip-model pilot this heater is using a honeywell "smart valve" system for intermittent pilot ignition. On a call fo...

  • Page 11: Lighting Instructions

    R-3122 page 11 for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in...

  • Page 12: Operating Instructions

    Page 12 r-3122 for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not t...

  • Page 13

    R-3122 page 13 start system check end sequence of operation trial for ignition main burner operation apply 24 vac to appliance thermostat calls for heat flame signal detected internal check ok • pilot valve opens • ignitor powered pilot light and flame is sensed during trial for ignition (1) • ignit...

  • Page 14

    Page 14 r-3122 smartvalve™ system troubleshooting sequence note: before troubleshooting, become familiar with the sequence of operation ip system troubleshooting sequence no no no yes yes no • turn off gas supply • disconnect system control harness • set thermostat to call for heat plug harness into...

  • Page 15

    R-3122 page 15 please note: when ordering parts, it is very important that part number and description of part coincide. Index part no. Number description index part no. Number description use only manufacturer's replacement parts. Use of any other parts could cause injury or death. 1 dv-1213 top pl...

  • Page 16

    Page 16 r-3122 empire comfort systems, inc. Nine eighteen freeburg ave. Belleville, illinois 62222-0529.