Empire Comfort Systems VFSE-18-1 Owner's Manual

Manual is about: Vented/Vent-Free Burner

Summary of VFSE-18-1

  • Page 1

    Installation instructions and owner's manual unvented gas log heater models intermittent models vfse-(18,24,30)-1 vent-free burner this is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provi...

  • Page 2: Table Of Contents

    26989-3-0510 page 2 section page important safety information .........................................................................................................................3 safety information for users of lp gas ...............................................................................

  • Page 3: Warning

    26989-3-0510 page 3 warning when used without adequate combustion and ventilation air, heater may give off carbon monoxide, an odorless, poisonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the written instructions provided with the...

  • Page 4

    26989-3-0510 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...

  • Page 5: Introduction

    26989-3-0510 page 5 important all correspondence should refer to complete model number, serial number and type of gas. Attention: during initial use of log you will detect an odor as the log is cured. Notice: during initial firing of this unit, its paint will bake out, and smoke will occur. To preve...

  • Page 6: General Information

    26989-3-0510 page 6 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. U...

  • Page 7: Clearances

    26989-3-0510 page 7 example of large room with 1/2 wall divider. Figure 1 the following formula can be used to determine the maximum heater rating per the definition of unconfined space: btu/hr = (l 1 + l 2 )ft x (w)ft x (h)ft x 1000 50 if the area in which the heater may be operated is smaller than...

  • Page 8: Clearances (Continued)

    26989-3-0510 page 8 mantel clearances with hood (figure 5) you must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 8" above fireplace opening. With sheet metal, you must have non-combustible material behind it. Heat resistant materials such ...

  • Page 9: Combustible Material

    26989-3-0510 page 9 do not attach combustible material to the mantel of your fireplace. This is a fire hazard. Figure 7 no greeting card, stockings or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles. Fi...

  • Page 10: Gas Supply

    26989-3-0510 page 10 check all local codes for requirements, especially for the size and type of gas supply line required. Note: never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: since some municipalities have additional local codes, it is alw...

  • Page 11

    26989-3-0510 page 11 refer to parts list, page 20 to order loose material (rock wool). Placing lava rock in front of burner on fireplace floor spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. Atten...

  • Page 12

    26989-3-0510 page 12 vfse series remote electronic ignition and control system timer/thermostat rf remote handset g6r-h3t application gv60 is a battery-powered electronic and control sys- tem for gas appliances with pilot burners and ods sys- tems. General notes radio frequency remote 433.92 mhz for...

  • Page 13

    26989-3-0510 page 13 standard, display, timer/thermostat rf remote handset • simultaneously press and hold the off and (large flame) buttons until a short beep confirms the start sequence has be- gun; release buttons. • continuing beeps confirm the ignition is in process. • once pilot ignition is co...

  • Page 14

    26989-3-0510 page 14 note: the display shows the set temperature every 30 sec- onds. Setting the temperature • select either the temp mode or the temp mode by briefly pressing the set button. • hold the set button until the temp display flashes. • set the desired temperature with (large flame) or (s...

  • Page 15

    26989-3-0510 page 15 7. With the manual knob in man position a manual pi- lot valve operator and piezo igniter are accessible. Ignition with match: fully push down manual pilot valve operator and hold in, to start pilot gas flow. Immediately light the pilot with a match, while continuing to hold in ...

  • Page 16

    26989-3-0510 page 16 to turn off gas to appliance for your safety read before lighting a. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. Before lighting smell all around the appliance area for gas. Be sure to smell next to the...

  • Page 17

    26989-3-0510 page 17 figure 17 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 18 shows a...

  • Page 18: Cleaning And Servicing

    26989-3-0510 page 18 annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Turn off heater and allow to cool before cleaning. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent...

  • Page 19: Troubleshooting

    26989-3-0510 page 19 if the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 1. When ignitor button is pressed, there is no spark at ods/ pilot. A. I...

  • Page 20: Parts List

    26989-3-0510 page 20 attention: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Parts list index no. Part no. Description 1 15426 rear log support (vfse-18) 1 1...

  • Page 21: Parts View

    26989-3-0510 page 21 13 11 12 parts view.

  • Page 22: How To Order Repair Parts

    26989-3-0510 page 22 to order parts under warranty, please contact your local empire dealer. See the dealer locator at www.Empirecomfort.Com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To ord...

  • Page 23: Appliance Service History

    26989-3-0510 page 23 appliance service history date dealer name service technician name service performed/notes.

  • Page 24: Empire

    26989-3-0510 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...