  • Page 1

    Installation instructions and owner's manual vented/vent-free burner empire empire comfort systems unvented gas log heater millivolt models vfsr-(16,18,24,30)-5 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and v...

  • Page 2: Table Of Contents

    28682-1-0811 page 2 section page important safety information .......................................................................................................... 3 safety information for users of lp-gas ......................................................................................... ...

  • Page 3: Warning

    28682-1-0811 page 3 when used without adequate combustion and ventilation air, heater may give off carbon monoxide, an odorless, poisonous gas. Do not install heater until all necessary provisions are made for combustion and ventilation air. Consult the written instructions provided with the heater ...

  • Page 4

    28682-1-0811 page 4 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to dete...

  • Page 5: Requirements For Canada

    28682-1-0811 page 5 requirements for canada this unit cannot be installed in a unvented application, this unit can only be installed as a vented application with these requirements. Important safety information this unit complies with ansi z21.60and cga 2.26 decorative gas appliances for installatio...

  • Page 6: Introduction

    28682-1-0811 page 6 attention: during initial use of log you will detect an odor as the log is cured. Notice: during initial firing of this unit, its paint will bake out, and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed. Warning this appl...

  • Page 7: Product Specifications

    28682-1-0811 page 7 product specifications model gas valve type btuh max. Rate btuh med. Rate btuh min. Rate vfsr-16 natural millivolt 25,000 — 17,500 vfsr-16 propane millivolt 22,500 — 15,750 vfsr-18 natural millivolt 32,000 — 22,000 vfsr-18 propane millivolt 32,000 — 22,000 vfsr-24 natural millivo...

  • Page 8: General Information

    28682-1-0811 page 8 this is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. U...

  • Page 9: Clearances

    28682-1-0811 page 9 h w l 1 l 2 fireplace divider example of large room with 1/2 wall divider. Figure 1 the following formula can be used to determine the maximum heater rating per the definition of unconfined space: btu/hr = (l 1 + l 2 )ft x (w)ft x (h)ft x 1000 50 if the area in which the heater m...

  • Page 10: Clearances (Continued)

    28682-1-0811 page 10 mantel clearances with hood (figure 5) you must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 8" above fireplace opening. With sheet metal, you must have non-combustible material behind it. Heat resistant materials such...

  • Page 11: Combustible Material

    28682-1-0811 page 11 for masonry built fireplaces free opening area of chimney damper for venting combustion products from decorative appliances for installation in solid fuel burning fireplaces • turn off gas supply to fireplace or firebox. • have the fireplace floor and chimney professionally clea...

  • Page 12

    28682-1-0811 page 12 notice: (damper clamp installation) when installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burning the logs for the first...

  • Page 13: Gas Supply

    28682-1-0811 page 13 check all local codes for requirements, especially for the size and type of gas supply line required. Notice : never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Notice : since some municipalities have additional local codes, it ...

  • Page 14

    28682-1-0811 page 14 placing lava rock in front of burner on fireplace floor spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. Attention: do not place lava rocks on burner, logs or rock wool. The la...

  • Page 15

    28682-1-0811 page 15 notice: for easy access to valve for lighting pilot, remove branch log and middle log from burner assembly before lighting. 1. Stop! Read the safety information label. 2. Make sure the manual shutoff valve is fully open. 3. This gas log set is equipped with an ignition device (p...

  • Page 16: Pilot Flame Characteristics

    28682-1-0811 page 16 figure 13 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 14 shows a...

  • Page 17: Cleaning And Servicing

    28682-1-0811 page 17 annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. Turn off heater and allow to cool before cleaning. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent...

  • Page 18: Wiring

    28682-1-0811 page 18 thermostats are not approved on vented decorative appliances. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 16", 18", 24" and 30" gas logs (millivolt) thermopile ...

  • Page 19: Troubleshooting

    28682-1-0811 page 19 if the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low, contact your local gas supplier immediately. 1. When ignitor button is pressed, there is no spark at ods/ pilot. A. I...

  • Page 20: Parts List

    28682-1-0811 page 20 attention: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Parts list index no. Part no. Description vfsr-16 vfsr-18 vfsr-24 vfsr-30 1 1542...

  • Page 21: Parts View

    28682-1-0811 page 21 parts view 14.

  • Page 22: How To Order Repair Parts

    28682-1-0811 page 22 to order parts under warranty, please contact your local empire dealer. See the dealer locator at www.Empirecomfort. Com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To or...

  • Page 23: Appliance Service History

    28682-1-0811 page 23 appliance service history date dealer name service technician name service performed/notes.

  • Page 24: Empire

    28682-1-0811 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...