Empire DV-20E-5 Installation Instructions And Owner's Manual

Manual is about: WALL FURNACE

Summary of DV-20E-5

  • Page 1

    Page 1 19562-1-0606 installation instructions and owner's manual patent # 5.664.555 warning: if not installed, operated and main- tained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious il...

  • Page 2: Table Of Contents

    Page 2 19562-1-0606 section page important safety information ..............................................................................................3 safety information for users of lp gas ..............................................................................4 requirements for massac...

  • Page 3

    Page 3 19562-1-0606 • due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. • young children should be...

  • Page 4

    Page 4 19562-1-0606 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...

  • Page 5

    Page 5 19562-1-0606 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust ve...

  • Page 6: Introduction

    Page 6 19562-1-0606 introduction always consult your local building department regarding regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to installer 1. Installer must leave instruction manual with owner after installation. 2. Installer mu...

  • Page 7: Gas Supply

    Page 7 19562-1-0606 consult the current national fuel gas code, ansi z223.1 can/ cga-b149 (.1 or .2) installation code. Recommended gas pipe diameter pipe length schedule 40 pipe inside diameter tubing, type l outside diameter nat. L.P. Nat. L.P. 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7...

  • Page 8: Gas Conversion Instructions

    Page 8 19562-1-0606 warning: conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. 1. Make sure gas supply to furnace is off prior to conversion and disconnect electrical power to unit. 2...

  • Page 9: Clearances

    Page 9 19562-1-0606 1. Pick a location on a wall with a clear space of 36" (91.4cm) high by 43" (109cm) wide in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close eno...

  • Page 10

    Page 10 19562-1-0606 installing wall bracket (figures 5 and 6) after finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the wall. Use the (2) 10 x 1" (25mm) he...

  • Page 11

    Page 11 19562-1-0606 be sure to deburr the ends with a file after cutting. Installation is easy after cutting the wall opening secure the vent terminal box in place using the (4) 10 x 1" hex-head screws provided. Locate the box so that the middle exhaust tube is directed toward the furnace exhaust ou...

  • Page 12

    Page 12 19562-1-0606 figure 11 condensate removal (figures 11 and 12) the condensate drain kit is used in conjunction with dve and dve-2, intake/exhaust extension kits. The condensate drain kit is required whenever there is a vertical vent run, in a heated room [10 ft. (3m) or more for dv-40e or 6 f...

  • Page 13: Lighting Instructions

    Page 13 19562-1-0606 for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automat...

  • Page 14: Wiring

    Page 14 19562-1-0606 the appliance, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, with the national electrical code, ansi/nfpa 70 or canadian electrical code, csa c22.1, if an external electrical source is utilized. This appli- ance...

  • Page 15: Maintenance

    Page 15 19562-1-0606 the hot surface ignitor is energized and after a 17 second warm- up, the gas valve circuit is energized, opening the gas valve and igniting the burners. After burning for about 30 seconds, the circulating air blower comes on, delivering warm air to the room. If ignition does not...

  • Page 16

    Page 16 19562-1-0606 furnace control board diagnostics fault sequence code — trouble shooting guide # of blinks fault condition fault correction steady on control ok 1 flash temperature limit switch is open -check circulating air blower inlet or grill outlet for blockage, inducer blower/circulating ...

  • Page 17: How To Order Repair Parts

    Page 17 19562-1-0606 index part no. Number description index part no. Number description 1 dv-1378 shroud top 2 dv-1376 shroud side right 3 r-2521 air filter 4 dv-1375 filter retainer 5 dv-1379 wall mounting bracket 6 dv-1048 wall bracket - 2 required 7 r-2586 control door pin - 2 required 8 19676 c...

  • Page 18: Parts View

    Page 18 19562-1-0606 parts view.

  • Page 19: Service Notes

    Page 19 19562-1-0606 service notes.

  • Page 20: Www.Empirecomfort.Com

    Page 20 19562-1-0606 empire comfort systems, inc. 918 freeburg ave. Belleville, il 62220 ph: 618-233-7420 or 800-851-3153 fax: 618-233-7097 or 800-443-8648 info@empirecomfort.Com www.Empirecomfort.Com.