Empire DV-55SPP Installation Instructions And Owner's Manual

Manual is about: FAN TYPE DIRECT VENT WALL FURNACE

Summary of DV-55SPP

  • Page 1

    Page 1 12431-7-0107 installation instructions and owner's manual fan type direct vent wall furnace model dv-55spp effective date january 2007 this appliance may be installed in an aftermarket, permanently located, manufactured home (usa only) or mobile home, where not prohibited by state or local co...

  • Page 2: Table Of Contents

    Page 2 12431-7-0107 section page important safety information ......................................................................................................................3 safety information for users of lp gas ..................................................................................

  • Page 3

    Page 3 12431-7-0107 this is a heating appliance do not operate this appliance without front panel installed. • due to high temperatures the appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the hazards of high surface temperat...

  • Page 4

    Page 4 12431-7-0107 some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detec...

  • Page 5

    Page 5 12431-7-0107 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust ve...

  • Page 6: Introduction

    Page 6 12431-7-0107 introduction always consult your local building department regarding regula- tions, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to installer 1. Installer must leave instruction manual with owner after instal- lation. 2. Installe...

  • Page 7: Gas Supply

    Page 7 12431-7-0107 locating gas supply the gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Note: never use pla...

  • Page 8: Clearances

    Page 8 12431-7-0107 clearances 1. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. 2. The dv-55 minimum wall depth is 4 1/2 inches and maximum wall depth is 13 inches. The use of tubes not supplied by the ma...

  • Page 9: Installation Instructions

    Page 9 12431-7-0107 locating wall opening the furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The furnace is 16 inches in width and normal 16 inches on center studs will not allow the furnace to be recessed into the wall unless ...

  • Page 10

    Page 10 12431-7-0107 cutting vent tubes this is the most important part of the installation. With the furnace installed on wall the 6" diameter air inlet tube and the 4" diam- eter flue outlet tube are to be marked and cut using the following procedure. 1. Attach 6" diameter air inlet tube onto the c...

  • Page 11

    Page 11 12431-7-0107 4. Apply furnace cement to 4" diameter flue outlet collar on combustion chamber and to 4" diameter collar on vent cap. Attach 4" diameter flue outlet tube onto flue outlet collar on combustion chamber. Attach vent cap into the 4" diameter flue outlet tube. Attach vent cap to outside...

  • Page 12: Lighting Instructions

    Page 12 12431-7-0107 1. Stop! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance. 4. Remove control access panel (lower front panel). 5. Turn gas control knob clockwise to "off." 6. Wait ten (10) minutes to clear out any gas. T...

  • Page 13: Pilot Flame Characteristics

    Page 13 12431-7-0107 the correct flame will be a short blue inner flame with a much larger light blue outer flame. The main burner (figure 12) shows the approximate height of each part of the flame for each gas. The burner does not have a primary air adjustment. The flame will be correct if the factory-s...

  • Page 14: Wiring

    Page 14 12431-7-0107 figure 13 wiring the appliance, when installed, must be electrically grounded in ac- cordance with local codes or, in the absence of local codes, with the national electrical code, ansi/nfpa 70 or canadian electrical code, csa c22.1, if an external electrical source is utilized....

  • Page 15

    Page 15 12431-7-0107 replacing fan and oiling the motor the fan motor should be cleaned and oiled once each heating season. To reach the motor, withdraw the metal shroud surrounding the fan blade by removing the screws on each side. Oil holes are located on the top at each end of the motor. Use a fe...

  • Page 16: How To Order Repair Parts

    Page 16 12431-7-0107 please note: when ordering parts, it is very important that part number and description of part coincide. Index part no. Number description use only manufacturer's replacement parts. Use of any other parts could cause injury or death. 1 11762 outer casing top 2 632024 motor moun...

  • Page 17: Parts View

    Page 17 12431-7-0107 parts view.

  • Page 18: Service Notes

    Page 18 12431-7-0107 service notes.

  • Page 19: Service Notes

    Page 19 12431-7-0107 service notes.

  • Page 20: Www.Empirecomfort.Com

    Page 20 12431-7-0107 empire comfort systems, inc. 918 freeburg ave. Belleville, il 62220 ph: 618-233-7420 or 800-851-3153 fax: 618-233-7097 or 800-443-8648 info@empirecomfort.Com www.Empirecomfort.Com.