Empire DVC-35-2IP Installation instructions and owner's manual

Manual is about: FAN TYPE DIRECT VENT WALL FURNACE

Summary of DVC-35-2IP

  • Page 1

    Page 1 installation instructions and owner’s manual fan type direct vent wall furnace model dvc-35-2spp dvc-35-2ip this appliance may be installed in an aftermarket, permanently located manufactured home (usa only) or mobile home, where not prohibited by state or local codes. This appliance is only ...

  • Page 2: Table of Contents

    32189-2-0414 page 2 table of contents important safety information ....................................................................................3 safety information for users of lp gas ...................................................................4 requirements for massachusetts ...........

  • Page 3

    32189-2-0414 page 3 important safety information this is a heating appliance do not operate this appliance without front panel installed. • due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the h...

  • Page 4

    32189-2-0414 page 4 safety information for users of lp-gas propane (lp-gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precau- tions which can protect both you and your family from an ac-...

  • Page 5

    32189-2-0414 page 5 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust ve...

  • Page 6: Introduction

    32189-2-0414 page 6 introduction introduction always consult your local building department regarding regula- tions, codes or ordinances which apply to the installation of a di- rect vent wall furnace. Instructions to installer. 1. Installer must leave instruction manual with owner after instal- lat...

  • Page 7: Gas Supply

    32189-2-0414 page 7 gas supply locating gas supply the gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Recomm...

  • Page 8: Clearances

    32189-2-0414 page 8 clearances checking manifold pressure both propane and natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0” w.C. (.996kpa) at the valve outlet with the inlet pressure to the valve from a min...

  • Page 9: Installation Instructions

    32189-2-0414 page 9 installation instructions locating wall opening the furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The fur- naces is 14 1/8” (358mm) in width and can be recessed between standard 16” (406mm) on center wall s...

  • Page 10

    32189-2-0414 page 10 locating electric supply a 7/8” (22mm) diameter knockout is provided at the bottom of the left and right side panels. A three-prong (grounding) plug assembly is located within the control compartment (bottom) of the furnace. Please remove 7/8” (22mm) knockout from appropriate si...

  • Page 11

    32189-2-0414 page 11 reassembly and resealing vent-air intake system when vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and resealing of the vent-air intake assembly. 1. Remove old caulking beneath the edge of the outside mount- ing pl...

  • Page 12

    32189-2-0414 page 12 dvc-35 spp standing pilot lighting instructions for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lig...

  • Page 13

    32189-2-0414 page 13 dvc-35ip intermittent pilot lighting instructions for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignitio...

  • Page 14: Pilot Flame Characteristics

    32189-2-0414 page 14 pilot flame characteristics the correct pilot flame (figure 11) will be blue, extending past the thermocouple. The flame will surround the thermocouple just be- low the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5” w.C. (1.245kpa). Remove the ...

  • Page 15: Wiring

    32189-2-0414 page 15 main burner flame characteristics the correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used. After the fur...

  • Page 16

    32189-2-0414 page 16 gas flow off on contro l igni t o r pressure regulator adjustment-under cap screw inlet pressure tap outlet pressure tap pilot adjustment- under cap screw pilot outlet wiring to 24 v. Thermosat to 24 v. Common on transformer to 24 v. “hot” on transformer ignitor-pilot assy. Ip-m...

  • Page 17

    32189-2-0414 page 17 service and maintenance suggestions general: all furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan op- eration, fan control, limit control and automatic valve operation. If the furnace fails to function on initial in...

  • Page 18

    32189-2-0414 page 18 dvc-35ip intermittent pilot sequence of operation start system check trial for ignition main burner operation end pilot valve opens ignitor powered flame signal detected thermostat calls for heat ignitor off main valve opens internal check ok pilot light and flame is sensed duri...

  • Page 19

    32189-2-0414 page 19 dvc-35ip intermittent pilot system troubleshooting sequence start ip system troubleshooting sequence turn off gas supply disconnect system control harness set thermostat to call for heat check for proper voltage at control harness (see inset a - voltage should be 24v between the...

  • Page 20: Parts List

    32189-2-0414 page 20 parts list please note: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer’s replacement parts. Use of any other parts could cause injury or death. Index no part no description 1 dv1213 top plate 2 r3165 door clip (...

  • Page 21: Parts View

    32189-2-0414 page 21 parts view.

  • Page 22: How to Order Repair Parts

    32189-2-0414 page 22 to order parts under warranty, please contact your local empire dealer. See the dealer locator at www.Empirecomfort. Com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit. To or...

  • Page 23: Warranty

    32189-2-0414 page 23 warranty empire comfort systems inc. Warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accor...

  • Page 24: Empire

    32189-2-0414 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...

  • Page 25

    Instructions pour l’installation et manuel du propriÉtaire radiateur mural À circulation forcÉe avec un Évent direct modÈles dvc-35-1spp dvc-35-1ip avertissement: si l’installation, l’usage et l’entretien de ce produit ne sont pas faits selon les instructions du fabricant, ce produit peut vous expos...

  • Page 26

    32189-2-0414 page 2 section page importante information de sécurité ......................................................................................3 information de sécurité pour les utilisateurs de propane ......................................................4 introduction .....................

  • Page 27

    32189-2-0414 page 3 ceci est un appareil de chauffage ne pas faire fonctionner cet appareil sans que la paroi frontale soit installÉe. • a cause des hautes températures, cet appareil doit être situé dans un endroit non achalandé et loin des meubles et des rideaux. • les enfants et les adultes doiven...

  • Page 28

    32189-2-0414 page 4 le propane est un gaz inflammable qui peut causer des feux et des ex- plosions. Dans son état naturel, le propane est inodore et sans couleur. Peut-être que vous ne connaissez pas toutes les précautions décrites ci- dessous? Elles peuvent vous protéger ainsi que votre famille con...

  • Page 29

    32189-2-0414 page 5 introduction toujours consulter le département de construction de votre région en ce qui regarde les règlements, les codes ou les ordonnances qui s’appliquent à l’installation d’un radiateur mural à évacuation directe. Instructions pour l’installateur 1. Après l’installation, l’i...

  • Page 30

    32189-2-0414 page 6 emplacement de l'alimentation de gaz la ligne de gaz peut entrer dans l’appareil soit en venant du plancher ou du mur extérieur. L’ouverture pour la ligne de gaz doit être faite à ce mo- ment. L’emplacement de l’ouverture sera déterminé par la position des solives du plancher et ...

  • Page 31

    32189-2-0414 page 7 figure 3 vérifier les pressions de gaz un régulateur de pression est incorporé dans la valve de gaz propane et celle de gaz naturel. Les modèles pour le gaz naturel auront des pressions de gaz approximativement de 4" w.C. (.996kpa) à la sortie de la valve et une pression d’entrée...

  • Page 32

    32189-2-0414 page 8 emmplacement de l’ouverture dans le mur le radiateur doit être situé sur un mur extérieur. Trouver les montants du mur, ainsi l’ouverture dans le mur sera entre les montants du mur. Le radiateur a une largeur de 14 1/8" (358mm) et peut être encastré entre deux montants dont la di...

  • Page 33

    32189-2-0414 page 9 emplacement de l’alimentation electrique sur le bas des panneaux des côtés gauche et droit, il y a une entrée défon- çable de 7/8" (22mm) de diamètre. L’assemblage de la fiche à trois broches (prise de terre) est situé dans le compartiment des commandes (au bas) du radiateur. S’i...

  • Page 34

    32189-2-0414 page 10 diamètre. Positionner la plaque extérieure de montage de façon à ce que le tuyau d’arrivée d’air de 6" (152mm) de diamètre ait une légère pente descendante vers l’extérieur. La pente descendante est néces- saire pour prévenir l’entrée de la pluie. Attacher la plaque extérieure d...

  • Page 35

    32189-2-0414 page 11 1. Arrêter! Lire les informations de sécurité ci-dessus. 2. Mettre le thermostat à son plus bas réglage. 3. Éteindre tout pouvoir électrique à l’appareil. 4. Enlever le panneau d’accès au contrôle (panneau du bas avant). 5. Tourner le bouton de contrôle de gaz dans le sens des a...

  • Page 36

    32189-2-0414 page 12 1. Mettre le thermostat au plus bas réglage. 2. Si l’entretien doit être fait, éteindre tout le pouvoir électrique à l’appareil. 3. Enlever la porte du panneau avant. Pour votre sÉcuritÉ lire avant d’allumer avertissement: si vous ne suivez pas exactement ces instructions, un fe...

  • Page 37

    32189-2-0414 page 13 la flamme de la veilleuse (figure 11) sera bleue et s’allongera plus loin que le thermocouple. La flamme entourera le thermocouple juste en- dessous de la pointe. Les veilleuses au gaz naturel exigent un ajustement lorsque la pression d’entrée de gaz est supérieure à 5.0" w.C. (...

  • Page 38

    32189-2-0414 page 14 la flamme convenable aura une petite flamme bleue intérieure avec une flamme extérieure bleue pâle beaucoup plus grande. Il n’y a pas d’ajustement d’air primaire pour le brûleur. La flamme se corrigera si la pression pré- ajustée à l’usine et les ouvertures sont utilisées. Après...

  • Page 39

    32189-2-0414 page 15 figure 14 ventilateur interrupteur du ventilateur interrupteur de fin de course boÎte du brÛleur soupape de gaz transformateur de la boÎte de jonction allumeur piezo off on contro l igni t o r 120 vac 120vac 24vac thermostat contro l igni t o r ajustement du rÉgulateur de pressi...

  • Page 40

    32189-2-0414 page 16 général: tous les radiateurs ont reçu un test d’allumage pour vérifier le bon fonctionnement. Ceci inclus la flamme du brûleur principal, la flamme de la veilleuse, le fonctionnement du ventilateur, le contrôle du ventilateur, le contrôle de fin de course et le fonctionnement de...

  • Page 41

    32189-2-0414 page 17 sÉquence de fonctionnement de la veilleuse intermittente pour le modÈle dvc-35ip - soupage de la veilleuse s'ouvre - allumeur est mis en fonction signal de la flamme est détecté thermostat effectue un appel de chaleur - allumeur off - soupape principal vérification interne ok la...

  • Page 42

    32189-2-0414 page 18 guide de dÉtection des dÉfectuositÉs du systÈme de la veilleuse inter- mittente pour le modÈle dvc-35ip départ - fermer l'alimentation de gaz - débrancher le harnais du système de contrôle - régler le thermostat pour un appel de chaleur vérifier que le harnais de contrôle ait le...

  • Page 43

    32189-2-0414 page 19 pour commander des pièces sous garantie, adressez-vous au revendeur empire local. Veuillez voir le concessionnaire au www.Empirecomfort.Com. Pour assurer un service sous garantie, le revendeur doit connaître votre nom, votre adresse, la date d’achat et le numéro de série du prod...

  • Page 44

    32189-2-0414 page 20 s’il vous plaÎt noter: lorsque vous commandez les pièces, il est très important que le numéro de la pièce et la description coïncident. Liste des piÈces numéro d’index numéro de la pièce description 1 dv-1213 plaque du dessus 2 r-3165 agrafe pour la porte (exige 2) 3 dv-1204 par...

  • Page 45

    32189-2-0414 page 21 veilleuse et support pour les modÉles spp vue des piÈces.

  • Page 46: Garantie

    32189-2-0414 page 22 empire comfort systems inc. Garantit que ce produit de chauffage individuel est exempt de défauts au moment de son achat et pen- dant les périodes indiquées ci-dessous. Les produits de chauffage individuel doivent être installés par un technicien qualifié et doivent être entrete...

  • Page 47

    32189-2-0414 page 23 maintenance historique de l’appareil date nom du distributeur nom du technicien de service entretien effectué/notes.

  • Page 48: Empire

    32189-2-0414 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.Com. Pour toute question d’entretien ou de réparation, veuillez contacter...