    Page 1 installation instructions and owner’s manual fan type direct vent wall furnace model dvc-35 this appliance may be installed in an aftermarket, permanently located manufactured home (usa only) or mobile home, where not prohibited by state or lo- cal codes. This appliance is only for use with t...

  • Page 2: Table Of Contents

    12430-11-1008 page 2 table of contents important safety information .................................................................................................3 safety information for users of lp gas .................................................................................4 requirement...

  • Page 3

    12430-11-1008 page 3 important safety information this is a heating appliance do not operate this appliance without front panel installed. • due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • children and adults should be alerted to the h...

  • Page 4

    12430-11-1008 page 4 safety information for users of lp-gas propane (lp-gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precau- tions which can protect both you and your family from an acci...

  • Page 5

    12430-11-1008 page 5 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust v...

  • Page 6: Introduction

    12430-11-1008 page 6 introduction introduction always consult your local building department regarding regulations, codes or ordinances which apply to the installation of a direct vent wall furnace. Instructions to installer. 1. Installer must leave instruction manual with owner after installa- tion...

  • Page 7: Gas Supply

    12430-11-1008 page 7 gas supply locating gas supply the gas line can enter the unit either through the floor or outside wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Recomme...

  • Page 8: Clearances

    12430-11-1008 page 8 clearances checking manifold pressure both propane and natural gas valves have a built-in pressure reg- ulator in the gas valve. Natural gas models will have a manifold pressure of approximately 4.0” w.C. (.996kpa) at the valve outlet with the inlet pressure to the valve from a ...

  • Page 9: Installation Instructions

    12430-11-1008 page 9 installation instructions locating wall opening the furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. The fur- naces is 14 1/8” (358mm) in width and can be recessed between standard 16” (406mm) on center wall ...

  • Page 10

    12430-11-1008 page 10 locating electric supply a 7/8” (22mm) diameter knockout is provided at the bottom of the left and right side panels. A three-prong (grounding) plug as- sembly is located within the control compartment (bottom) of the furnace. Please remove 7/8” (22mm) knockout from appropriate...

  • Page 11

    12430-11-1008 page 11 reassembly and resealing vent-air intake system when vent-air intake system is removed for servicing the furnace, the following steps will assure proper reassembly and resealing of the vent-air intake assembly. 1. Remove old caulking beneath the edge of the outside mount- ing p...

  • Page 12

    12430-11-1008 page 12 dvc-35 spp standing pilot lighting instructions for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lig...

  • Page 13

    12430-11-1008 page 13 dvc-35ip intermittent pilot lighting instructions for your safety read before lighting warning: if you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an igni- t...

  • Page 14: Pilot Flame Characteristics

    12430-11-1008 page 14 pilot flame characteristics the correct pilot flame (figure 11) will be blue, extending past the thermocouple. The flame will surround the thermocouple just below the tip. Natural gas pilots require adjusting when the inlet gas pressure is above 5” w.C. (1.245kpa). Remove the pil...

  • Page 15: Wiring

    12430-11-1008 page 15 main burner flame characteristics the correct flame will be a short, blue inner flame with a much larger, light blue, outer flame. The burner does not have a primary air adjustment. The flame will be correct if the factory-set pressure and orifice opening are used. After the furnace...

  • Page 16

    12430-11-1008 page 16 gas flow off on control igni t o r pressure regulator adjustment-under cap screw inlet pressure tap outlet pressure tap pilot adjustment- under cap screw pilot outlet wiring to 24 v. Thermosat to 24 v. Common on transformer to 24 v. “hot” on transformer ignitor-pilot assy. Ip-m...

  • Page 17

    12430-11-1008 page 17 service and maintenance suggestions general: all furnaces have been fire-tested to check for proper operation. This includes, main burner flame, pilot flame, fan opera- tion, fan control, limit control and automatic valve operation. If the furnace fails to function on initial inst...

  • Page 18

    12430-11-1008 page 18 dvc-35ip intermittent pilot sequence of operation start system check trial for ignition main burner operation end pilot valve opens ignitor powered flame signal detected thermostat calls for heat ignitor off main valve opens internal check ok pilot light and flame is sensed dur...

  • Page 19

    12430-11-1008 page 19 dvc-35ip intermittent pilot system troubleshooting sequence start ip system troubleshooting sequence turn off gas supply disconnect system control harness set thermostat to call for heat check for proper voltage at control harness (see inseta- voltage should be 24v between ther...

  • Page 20: How To Order Repair Parts

    12430-11-1008 page 20 how to order repair parts parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the parts list h...

  • Page 21: Parts View

    12430-11-1008 page 21 parts view.

  • Page 22: Empire

    12430-11-1008 page 24 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfor...