Empire DVP30CA30BN-2 Installation Instructions And Owner's Manual

Manual is about: Cast Iron Direct Vent STOVE

Summary of DVP30CA30BN-2

  • Page 1

    The heritage cast iron stoves installation instructions and owner's manual this appliance may be installed in an aftermarket permanently located, manufactured home (usa only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rat...

  • Page 2

    26127-1-1209 page 2 section page important safety information ............................................................................................... 3 safety information for users of lp-gas .............................................................................. 4 requirements for mas...

  • Page 3

    26127-1-1209 page 3 important safety information before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. Do not operate this appliance without glass front panel installed • due to high temperatures the appliance should be located out of traffic and away from ...

  • Page 4

    26127-1-1209 page 4 some points to remember no odor detected - odor fade lp-gas warning odor if a gas leak happens, you should be able to smell the gas because of the odorant put in the lp-gas. That's your signal to go into immediate action! Safety information for users of lp-gas propane (lp-gas) is...

  • Page 5

    26127-1-1209 page 5 requirements for massachusetts for all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the commonwealth and where the side wall exhaust ve...

  • Page 6: Introduction

    26127-1-1209 page 6 instructions to installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with the fireplace. 3. Installer should show owner how to start and operate the fireplace. This direct vent ga...

  • Page 7

    26127-1-1209 page 7 specifications model dvp30ca30(b,f,s,m,w) natural gas propane (lp) input btu/hr (kw/h) maximum 32,000 (9.3) 30,000 (8.7) btu/hr (kw/h) minimum 22,400 (6.5) 22,000 (6.4) height 27 3/4" (705 mm) 27 3/4" (705 mm) width 28 1/16" (713 mm) 28 1/16" (713 mm) depth 17 3/8" (442 mm) 17 3/...

  • Page 8

    26127-1-1209 page 8 consult the current national fuel gas code, ansi z223.1 can/ cga-b149 (.1 or .2) installation code. Note: never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: since some municipalities have additional local codes, it is always...

  • Page 9

    26127-1-1209 page 9 in selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper opera- tion. Locating and venting the direct vent fireplace clearances: when facing the front of the direct vent fireplace the minimum clearances to com...

  • Page 10

    26127-1-1209 page 10 figure 5 special vent systems the following vent systems are acceptable for use with the dvp30ca fireplace: simpson duravent® gs 4" - 6 5/8" *american metal® 4" - 6 5/8" *selkirk direct-temp® 4" - 6 5/8" * american metal® and selkirk direct-temp® can not be used in side wall hor...

  • Page 11

    26127-1-1209 page 11 venting fireplace (cont.) sidewall venting the maximum vertical and horizontal distances are 25 feet and 12 feet, respectively. Vertical dimensions are based on top of fireplace to centerline of pipe. Horizontal dimensions are based on centerline of pipe to termination. Caution:...

  • Page 12

    26127-1-1209 page 12 the restrictor plate is to be used only in a completely vertical vent installation. The restrictor plate can be used when the vertical vent rise is between 10 feet and 25 feet. In a vertical vent rise the rear (yellow) flames on the main burner can be reduced due to the drawing ...

  • Page 13

    26127-1-1209 page 13 adjusting air shutter the air shutter has been factory set to the optimum performance level for this appliance. Lp air shutter is not adjustable. 1. Remove cast iron top and carefully set aside. 2. Remove cast iron front and carefully set aside. 3. Carefully remove glass door. S...

  • Page 14

    26127-1-1209 page 14 termination clearance for buildings with combustible and noncombustible exteriors. Vertical sidewall installations important! Minimum clearance between vent pipes and combustible materials is one inch (1") (25 mm) on, bottom and sides and (2") (51 mm) on top. Important! When ven...

  • Page 15

    26127-1-1209 page 15 figure 15 a = *clearance above grade, veranda, porch, deck or balcony [*12 inches (304.8 mm) minimum] b = clearance to window or door that may be opened [*9 inches (228.6 mm) minimum for appliances (14.6 kw) c = clearance to permanently closed window [minimum 12 inches (304.8 mm...

  • Page 16

    26127-1-1209 page 16 installing vent components (figure 16 and figure 17) begin the vent system installation by installing the first simpson duravent component, a straight pipe on the top of the appliance, or rotate the vent elbow to the horizontal position then add horizontal and vertical pipe leng...

  • Page 17

    26127-1-1209 page 17 installing support brackets (figure 18) a horizontal pipe support must be used for each 3 feet of horizontal run. The pipe supports should be placed around 6 5/8 inch diameter pipe and nailed in place to framing members. There must be a 2 inch clearance to combustibles above 6 5...

  • Page 18

    26127-1-1209 page 18 figure 21 figure 22 attach and secure the termination to the last section of horizontal venting by sliding cap over the last section of horizontal venting to ensure proper location. Note: termination cap should pass through the wall firestop from the exterior of the building. Ad...

  • Page 19

    26127-1-1209 page 19 vertical terminations (figures 24, 25, and 26) locate and mark the center point of the venting pipe. Using a nail on the underside of the roof and drive this nail through this center point. Make the outline of the roof hole around this center point. Note: size of the roof hole d...

  • Page 20

    26127-1-1209 page 20 installing support brackets a horizontal pipe support must be used for each 3 feet of horizontal run. The pipe supports should be placed around 6 5/8 inch diameter pipe and nailed in place to framing members. There must be a 2 inch clearance to combustibles above 6 5/8 inch diam...

  • Page 21

    26127-1-1209 page 21 1. Remove cast iron top and carefully set aside. 2. Remove cast iron front and carefully set aside. 3. Lower valve cover on firebox. 4. Release two door latches at bottom of firebox. 5. Grasp bottom of glass frame, lift glass frame upward in order to release glass frame from lip...

  • Page 22

    26127-1-1209 page 22 before operating this heater, please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below. 1. Know what type of ignition system this model has (standing pilot) and follow the applicable safety and lighting instructions....

  • Page 23

    26127-1-1209 page 23 1. Stop! Read the safety information above. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the appliance (if appli- cable). 4. Lower valve cover. 5. Push in gas control knob slightly and turn clockwise to "off." 6. Wait ten (10) minutes to clear out a...

  • Page 24

    26127-1-1209 page 24 figure 30 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple and thermopile. The flame will surround the thermocouple and thermopile just below the tip. A slight yellow flame may occur where the pilot flame and main burner...

  • Page 25

    26127-1-1209 page 25 figure 31 shows a correct main burner flame pattern. Figure 32 shows an incorrect main burner flame pattern. If main burner flame pattern is incorrect, as shown in figure 32: • see troubleshooting, page 29. Cleaning and maintenance / main burner warning: turn off heater and let ...

  • Page 26

    26127-1-1209 page 26 desired, turn the on/off/remote switch on wire channel from the remote position to the on position. 1. Connect (1) wire from the 750 millivolt wall thermostat and (1) wire from appropriate accessory to the green, stripped and bare wire from the on/off/remote wire harness. 2. Con...

  • Page 27

    26127-1-1209 page 27 wiring diagram figure 34 wiring (continued).

  • Page 28

    26127-1-1209 page 28 a qualified service person recommended by your empire dealer should conduct an annual inspection and maintenance of the appliance, its venting, and the installation to keep it running safely and efficiently. The follow- ing procedures should be performed only by a qualified serv...

  • Page 29

    26127-1-1209 page 29 1. Spark ignitor will not light pilot after repeated depressing of piezo ignitor button. A. Defective ignitor (no spark at electrode) - check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace ignitor. B. No gas or low gas pressure. -...

  • Page 30: How To Order Repair Parts

    26127-1-1209 page 30 please note: when ordering parts, it is very important that part number and description of part coincide. Use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Parts list empire comfort systems, inc. Nine eighteen freeburg ave. Belleville...

  • Page 31

    26127-1-1209 page 31 parts view 1 9 4 2 3 4 6 4 8 10 11 12 14 15 16 28 29 31 36 37 38 39 40 41 42 43 44 45 30 17 18 19 20 21 22 24 25 26 27 32 34 35 23 13 33 5 7 29 47 9 46.

  • Page 32

    26127-1-1209 page 32 casting parts list use only manufacturer's replacement parts. Use of any other parts could cause injury or death. Please note: when ordering parts, it is very important that part number and description of part coincide. Index no. Part no. Description common parts 10 r-9671 inser...

  • Page 33

    26127-1-1209 page 33 1 2 8 3 4 5 6 7 9 9 10 10 10 10 12 11 11 12 casting parts view.

  • Page 34

    26127-1-1209 page 34 accessory side shelves installation instructions installing accessory side shelves: 1. Remove cast iron or stone inlay inserts from casting top and carefully set them aside. 2. Remove cast iron top from stove and place upside down on a flat, soft smooth surface to avoid damage. ...

  • Page 35

    26127-1-1209 page 35 optional blower installation instructions installing optional cib3 blower 1. Loosen, but do not remove, four (4) hex-head screws located on the exterior, bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has four (4) keyho...

  • Page 36

    26127-1-1209 page 36 caution: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Cleaning the blower wheel will collect lint and could require cleaning once a year. If the air output decre...

  • Page 37

    26127-1-1209 page 37 service notes parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the parts list have a part nu...

  • Page 38

    26127-1-1209 page 38 service notes.

  • Page 39: Models:

    26127-1-1209 page 39 specifications model dvp30c(a,b)30(b,f,s,w) lp nat input btu/hr (kw/h) maximum 30,000 (9.3) 32,000 (9.3) btu/hr (kw/h) minimum 22,000 (5.9) 22,400 (6.5) height 27 3/4” (705 mm) width 28 1/16" (713 mm) depth 17 3/8" (442 mm) gas inlet (pipe) 1/2" (13 mm) web site: www.Empirecomfo...

  • Page 40: Empire

    26127-1-1209 page 40 empire empire comfort systems empire comfort systems inc. 918 freeburg ave. Belleville, il 62220 if you have a general question about our products, please e-mail us at info@empirecomfort.Com. If you have a service or repair question, please contact your dealer. Www.Empirecomfort...