    Instruction manual for the manufactured by e-s c 1602 series carriage door instructions.

  • Page 2

    Ce declaration of conformity of machines (directive 89/392/eec, annex ii, part b) manufacturer: faac s.P.A. Address: via benini, 1 – 40069 zola predosa bologna – italy declares that: eurotrigon 0224 - trigon k 24 a.K.A. Estate swing (usa) mod operator • is built to be integrated into a machine or to...

  • Page 3: Class I:

    Estate swing summery of functions the estate swing is only to be used for vehicular swing doors in a class i setting. Class i: a vehicular door opener (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith. The faac estate swing...

  • Page 4

    The table of contents are listed to assist you locating a desired section. We do how- ever strongly suggest studying every page of the instruction manual before attempt- ing installation. Section: • review of specifications, warnings, and tools 1 ⇒ specifications of the estate swing and components 1...

  • Page 5

    Marks pages with opener or usage warnings. Although we have marked these as very important warnings, please read the entire manual. Every step is important to the correct installation of your door opener. The table of contents are listed to assist you locating a desired section. We do how- ever stro...

  • Page 6

    Model estate swing e-sc 1600 power supply 115v ac/ 24v ac rated absorbed power (amperage pull on a 120v ac outlet) 3 amp/single 5 amp/dual max torque (nm) 200 use frequency (cycles/hour) > 100 operating ambient temperature -4 to 131 deg f gearmotor weight (lbs) 25 protection class ip44 door leaf max...

  • Page 7

    1.2 es ta te s w in g p a rt s l is t 1. Housing cover 2. Wall mounting plate 3. Manual release key 4. Manual release 5. 24vdc motor 6. Transmission shaft 7. Straight lever of articulating arm 8. Curved lever of articulating arm 9. Door mounting bracket 10. Control box 11. Control board 12. Transmit...

  • Page 8

    T o o ls n e e d e d other items that may be needed prior to commencing installation. • start and stop post, bracket or door stop. Although the estate swing e-sc 1602 features soft start/stop and can be used with limit switches (not included), it is possible to use the e-sc 1602 without limit switch...

  • Page 9

    Manual operation mode manual operation mode will be necessary to learn from installation and programming. It is also useful for emergency situations where as using the motor is not an option from operation the doors. Fit the supplied allen wrench and turn it by approximately a half a turn until it s...

  • Page 10

    Important: determining correct position 3.1 this operator is intended to be on the inside of the garage and push the carriage doors out towards the driveway. Position the mounting plate above the door frame with the inside end in line with the edge of the door frame. The drive shaft (piece that come...

  • Page 11

    Installation of operator the operator base plate and articulated arm are designed either for right-handed or left-handed installation. There is no pre-determined designation. 1. Begin with your gear motor in the base plate. Hold the base and motor against the wall above the door and find the proper ...

  • Page 12

    4. Assemble the articulated arm and front coupling as shown below. Left assembly connects the same way as the right only with the straight arm and door bracket on opposite sides as in the smaller picture below. 5. Fit the straight lever of the articulated arm on the transmission shaft and tighten it...

  • Page 13

    Mounting the control board and box 1. Position your control box on the post of the door or a near by fence. Use the knockouts labeled “a” in the picture to the right to mount your control box to the post or fence. For a dual operator set-up, the control box will be on the same side of the driveway a...

  • Page 14

    4.2 for your convenience the white terminal strips on the control board are easily removed for wiring. Simply pull straight out on the terminal strip to remove it from the board. It will slide right off. Slide it back on when you are finished with your wiring connections..

  • Page 15: Positive Stops

    Installation of limit switches and positive stops positive stops are physical structures the doors come in contact with at the end of the opening and closing cycles. Although the e-sc 1602 control board comes equipped with a cycle time learning function, physical stopping mechanisms must still be us...

  • Page 16

    4.4 wiring the limit switches on the limit switch: • 1 is common • 2 is n/c limit connection • 4 is not used example of how to tighten the limit ring. Terminal block cn3 comf common from all limit switches fcc1 n/c limit connection closed door limit switch on master fca1 n/c limit connection open do...

  • Page 17: Only If Not Using

    Temporary safety jumpers for the highest level of safety, the estate swing systems are set up with normally closed safety terminals. This means that in order for the door opener to move these terminals must be closed either through a safety device (recommended) or with jumpers. Temporary safety jump...

  • Page 18

    Wiring the operator arm(s) for the master operator: in terminal block cn2 insert the brown wire in apm1 and blue wire in chm1. For the slave operator : in terminal block cn2 insert the blue wire in apm2 and brown wire in chm2. *during the learning process, if either door begins to move in the open d...

  • Page 19

    4.7 installing and setting transmitters and receivers installing the receiver 1) locate the 5 silver pins in the lower right hand corner of the estate swing board. 2) locate the white connector on the receiver. 3) push the white connector from the receiver on the 5 pins on your control board with th...

  • Page 20

    4.8 power 1. The estate swing e-sc 1602 comes with 1) 24v transformer. The transformer sup- plied has 2 screw terminals to connect to. You may locate the transformer up to 1000’ away from the control board using wire ratings as specified below. 2. Insert the two wires from the transformer into the t...

  • Page 21

    Setting operating parameters complete this step prior to programming the door run time. This will dictate how your door will react during programming and normal op- eration. It is not necessary to reset these if power is removed or if reset is tripped, they will stay set. Entering programming mode 1...

  • Page 22

    Operating parameters chart minimum force medium-low force medium-high force high force this parameter adjusts the sensitivity of the electronic clutch system. The electronic clutch system controls the anti-crushing auto-reverse feature when a door in motion makes contact with an obstacle. 1.5 second...

  • Page 23

    20% of total arch 10% of total arch soft start/ stop this parameter determines when the door will begin to slow down near the end of opening and closing cycle. Low high soft speed this parameter determines how fast the door will move during the soft start/stop. If using positive stops this parameter...

  • Page 24: Important:

    Programming door run times in this stage, your control board will memorize where your limits are (identified by limit switches, positive stops or both) in both opening and closing phases. Also if the auto-close fea- ture is activated it will learn the user specified pause time. For safety purposes—y...

  • Page 25

    5. When the closing stop point or limit switch is reached, the motor pauses for approximately 2 seconds, and then restarts with a total opening maneuver to the opening stop point or limit switch. 6. When the full open stop or limit switch is reached the doors will stop. 7. Wait for the amount of tim...

  • Page 26: Door Status

    Control board led lights - the control board led lights are located above their respec- tive terminals that they represent. (with exception of alim, power supply light, which is located below the power terminals in the upper left corner.) the led lights are a quick way of verifying necessary connect...

  • Page 27

    6.2 troubleshooting if the door opener will not move. Be sure you have gone through programming. Without programming no power is ever sent to the operator arms. Check wiring connections. Check to be sure jumpers are in place between stop, fsw op, fsw cl to com on terminal block cn4. If not using lim...

  • Page 28

    6.3 if fuse the f2 fuse blows or continues to blow. Check all wiring to both the backup batteries and to all accessories run off of the 24+,- terminals on terminal block cn1. Check for the following: · the batteries are run in series not parallel. If they are run in parallel the batteries will be- c...

  • Page 29: Cn1

    Control board overview 7.1 caution! Do not run 110v ac power direct to the board. This will cause permanent damage to both boards and void your warrantee. Caution! Cn1 - upper left hand corner of board, used for power and back up power. • vac - terminals. The input terminals for the supplied 24v tra...

  • Page 30: Cn2 -

    Cn2 - located on the lower left side of the board, these terminals are outputs for the opera- tor arm(s), door locks (optional), and lamps (optional). • apm1, chm1 - terminals. For dual operations these terminals are for the arm that must move first, for single operations these terminals are the out...

  • Page 31

    Photocell & safety device guide before connecting the photocells (or other devices) we advise you to select the type of operation according to the movement zone to be protected. Opening safety devices: they operate only during the door opening movement and, therefore, they are suitable for protectin...

  • Page 32

    Accessory manuals for most make and model accessories can be found on the web at: www.Estateswing.Com/accessories the accessory manuals you have or find at the above address may be written to coincide with that manufacturers model of door opener. To determine correct terminals on your estate swing o...