Faber Clear Installation Manual

Other manuals for Clear: Installation Manual

Summary of Clear

  • Page 1

    Clear 40010631 - 0811 installation guide uk irl.

  • Page 2

    Uk irl content 1.1 1.2 1.3 1.4 1 1.5 1.6 1.7 1.8 a b c d.

  • Page 3

    Uk irl > > > > 2 clear with wirdum 770 surround 2.1 2.2 2.3 2.4.

  • Page 4

    Uk irl clear frameless 3.1 3.2 3.3 3.4 3.

  • Page 5

    Uk irl > > > > 4 (de)mounting the glass 4.1 4.2 4.3 4.4 4.5 4.6 4.7.

  • Page 6

    5 uk irl content 1 introduction ......................................................................................... 6 2 safety and general information .................................................................. 7 3 installation requirements .................................................

  • Page 7

    > > > > 6 uk irl 1 introduction note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. This manual covers both models. Both are developed to be installed in 3 ways: • frameless in an existing builders opening or false chimn...

  • Page 8

    7 uk irl 2 safety and general information before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain...

  • Page 9

    > > > > 8 uk irl 3 installation requirements note: since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Due to the natural circulation of air, moist and volatile components from pai...

  • Page 10

    9 uk irl 3.3 flue requirements the appliance is of the type c11/c31. The appliance will need to be supplied with the approved faber flue pipes and terminal, it is not possible to supply your own. The minimum effective height of the flue system must be 1 meter. Flue routing: • a horizontal extension ...

  • Page 11

    > > > > 10 uk irl • avoid locating the terminal in close proximity to plastic materials such as gutters or other combustibles. If this is unavoidable then a suitable deflector should be made. • some important requirements for a good functioning are • the wall-mounted terminal has to be at least 0,5 ...

  • Page 12

    11 uk irl 4 instruction for installation 4.1 gas connection installation pipes should be in accordance with bs 6891. Pipe work from the meter to the appliance must be of adequate size. The complete installation including the meter must be tested for soundness and purged as described in the above cod...

  • Page 13

    > > > > 12 uk irl 4.4 false chimney brest without surround build the false chimney using promatect the measure in the clear of the false himney brest has to be 770x782 (width x height). These sizes are including the finishing layers check regularly and before the finishing layer if the glass can be ...

  • Page 14

    13 uk irl 4.5.2 assembly of the surround • establish the central point of the fireplace and mark this on the backing wall • establish the distance between the appliance and the backing wall • if the backing wall is not level, you can fill it later • lay the floor plate so that it is level in all dir...

  • Page 15

    > > > > 14 uk irl 4.6 removal of the glass two suction pads are delivered with the appliance to make removal easier. Always clean the suction lifters before use remove the side panels (see figure 4.6) remove the lower panel (see figure 4.5) unscrew the cover panels on the left and the right (see fig...

  • Page 16

    15 uk irl 5 commissioning (functional checks) 5.1 pilot ignition check • ignite the pilot light as described in the user manual • check if the pilot burner stays alight • extinguish the pilot burner 5.2 check functional burner and pilot burner the appliance is preset to give the correct heat input. ...

  • Page 17

    > > > > 16 uk irl 6 handing over (final check and customer briefing) instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries advise the customer how to clean the appliance including the glass hand over these instructions including the u...

  • Page 18

    17 uk irl attention: before placing the glass: check the glass sealing rope is in good condition and makes an effective seal. Be sure that there are no fingerprints on the glass. It is not possible to remove those prints after you burn the appliance for a while (they are burnt in). Place the glass i...

  • Page 19

    > > > > 18 uk irl appendix a: example calculation calculation 1: calculating horizontal extension fig. 2a: flue length c + e = 1m + 1m 2 m elbows d = 2m 2 m total horizontal extension 4 m measure or calculate effective height (hvert) flue length a 1 m roof mounted terminal 1 m total effective height...

  • Page 20

    19 uk irl appendix b: flue restrictor determine the right flue restrictor: • calculate the total horizontal- and vertical length of the flue, according to the calculations in appendix a • determine according to the table the right flue restrictor size • when meeting an x, and when the values are out...

  • Page 21

    > > > > 20 uk irl appendix c: installation of the flue connection with use of concentric duct material make a hole of ø 153 mm for the wall or roof mounted terminal. The horizontal pipes need to rise away from the appliance at a rate of 3 degrees per metre build the system starting from the applianc...

  • Page 22

    21 uk irl appendix d: technical specifications flatburner flatburner flatburner country uk / irl uk / irl cat ii 2e+3+ ii 2h3+ appliancetype c11 of c31 c11 of c31 reference gas g20 g31 input (nett) kw 8.8 7.6 efficiency class 2 2 inlet pressure mbar 20 37 gas rate* l/h 925 350 gas rate* gram/h 660 w...

  • Page 23

    > > > > 22 uk irl appendix e: technical specifications logburner logburner logburner country uk / irl uk / irl cat ii 2e+3+ ii 2h3+ appliancetype c11 of c31 c11 of c31 reference gas g20 g31 input (nett) kw 7.5 7.2 efficiency class 2 2 inlet pressure mbar 20 37 gas rate* l/h 790 293 gas rate* gram/h ...

  • Page 24

    23 uk irl appendix f: dimensions clear frameless.

  • Page 25

    > > > > 24 uk irl appendix g: dim. Clear with wirdum surround.

  • Page 26

    25 uk irl appendix h :dimensions convection grid.

  • Page 27

    > > > > 26 uk irl appendix j : dimensions control box door.

  • Page 28