Installation instructions 12 1 dear user congratulations on purchasing your faber product, a quality product that will provide you with the warmth and atmosphere for many years. Please read the user manual before using the fire. Should a malfunction occur despite the careful final checks, then you c...
Installation instructions 13 the combined supply and discharge can be done both via wall or through the roof or through an existing chimney. Verify if the position of the terminal meets the local regulations regarding ventilation openings. The flue outlet can end on an external wall or a roof. Check...
Installation instructions 14 4.4.1 hanging on the wall 800/500-650-iil, -iir and -iii the appliance can be wall-mounted with the optional wall bracket (see fig. 1.8). • when penetrating a non-combustible wall or ceiling the opening must be at least 5mm larger than the diameter of the discharge mater...
Installation instructions 15 it is not necessary to take out the glass from the side to place the log set or for maintenance. 800/500-650-iil, iir and iii • first, remove the front glass (see chapter 5.1). • remove the left or right clamp strip on the top (fig. 3.4). • place the suction cups on the ...
Installation instructions 16 8 instructions for client • recommend that the unit should be checked annually by a qualified specialist to ensure the safe use and to guarantee a long service life. • give advice and instructions on care and cleaning of the glass. Highlight the danger of burnt-in finger...
Installation instructions 17 • pipes under a tilt angle: these are pipes which are vertically ascending at an angle of 30° or 45° (fig. 12.1 c). Fill in only in combination with at least 2x 30 or 45° bends in the vertical part. • restrictor table: see the restrictor table at the right vertical (tvh)...
Installation instructions 18 starting length (stl), vertical (tvh) and horizontal (thl) stl 0,2 0,5 1 1,5 thl 0 1 2 3 4 5 6 7 8 9 10 tvh 0 x x x x x x x x x x x 0,5 x x x x x x x x x x x 1 0,2 x x x x x x x x x x 1,5 40,2 x x x x x x x x x x 2 45,2 x x x x x x x x x x 3 45,2 x x x x x x x x x x 4 45...
Installation instructions 19 11.2 restrictor table (130/200) ng matrix 800/500 starting length (stl), vertical (tvh) and horizontal (thl) stl 0,2 0,5 1 1 1 1 1 thl 0 1 2 3 4 5 6 7 8 9 10 tvh 0 x x x x x x x x x x x 0,5 x 0,4 x x x x x x x x x 1 0,4 0,3 30,4 30,4 0,4 0,4 0,4 x x x x 1,5 30,4 30,3 30,...
Installation instructions 20 11.3 restrictor table (130/200) ng matrix 800/650 starting length (stl), vertical (tvh) and horizontal (thl) stl 0,2 0,5 1 1 1 1 1 thl 0 1 2 3 4 5 6 7 8 9 10 tvh 0 x x x x x x x x x x x 0,5 x 0,4 x x x x x x x x x 1 0,4 0,3 0,4 0,4 0,4 0,4 0,4 x x x x 1,5 30,4 30,3 30,4 ...
Installation instructions 21 11.4 restrictor table (130/200) lpg matrix 800/500 starting length (stl), vertical (tvh) and horizontal (thl) stl 0,2 1 1 1 1 1 1 1 1 thl 0 1 2 3 4 5 6 7 8 9 10 tvh 0 x x x x x x x x x x x 0,5 x x x x x x x x x x x 1 0,4 40,4 30,4 30,4 0,4 0,4 0,4 x x x x 1,5 40,4 40,4 4...
Installation instructions 22 11.5 restrictor table (130/200) lpg matrix 800/650 starting length (stl), vertical (tvh) and horizontal (thl) stl 0,2 1 1 1 1 1 1 1 1 thl 0 1 2 3 4 5 6 7 8 9 10 tvh 0 x x x x x x x x x x x 0,5 x x x x x x x x x x x 1 0,4 0,4 0,4 0,4 0,4 0,4 0,4 x x x x 1,5 40,4 40,4 40,4...
Installation instructions 23 12 examples flue materials fig. 12.1 fig.12.2 fig. 12.3.
Installation instructions 24 13 calculation sheet starter length (stl) first part on top of the appliance value value flue length from 0,1m till 0,45m 0,2 flue length from 0,5m till 0,90m 0,5 flue length from 1m till 1,4m 1 flue length from 1,5m till 2m 1,5 flue length 2m or more 2 bend 90° 0,1 bend...
Installation instructions 25 search in the table at tvh and thl and enter the value that is found. Found value ……………………………… if the detected value is a number, check whether the completed stl is higher or equal to the value in the table. Is the stl value lower as specified in the table then the insta...
Installation instructions 26 14 tecnical data 14.1 matrix 800/500 gas category ii2h3+ ii2h3+ ii2h3+ type appliance c11/c31/c91 c11/c31/c91 c11/c31/c91 reference gas g20 g30 g31 input hi kw 9,5 9,5 9,5 efficiency class 1 1 1 nox-class 4 4 4 inlet pressure mbar 20 30 37 gas rate (at 15º c and 1013 mba...
Installation instructions 27 14.2 matrix 800/650 gas category ii2h3+ ii2h3+ ii2h3+ type appliance c11/c31/c91 c11/c31/c91 c11/c31/c91 reference gas g20 g30 g31 input hi kw 11,3 11,3 11,3 efficiency class 1 1 1 nox-class 4 4 4 inlet pressure mbar 20 30 37 gas rate (at 15º c and 1013 mbar) m³/h 1,187 ...
Installation instructions 28 in the building regulations. Short roof terminal. Only for existing chimney connection extension pipe 15 terminal position > please note: these rules apply only for the proper functioning of the unit, for ventilation and environmental protection you need to comply with t...
Installation instructions 29 16 guide de dépannage light the pilot flame with the remote, beep every second? - learn a new code for remote. - battery remote. No - battery receiver. - faulty adapter. - faulty receiver. - see inst. Manual. - 1x 9v alkaline. - 4x 1.5v aa alkaline. - replace 6v adapter....
Installation instructions 30 pilot stays lit no no no yes yes no main burner stays on? Pilot lift, thermocouple not in pilot flame anymore. No solenoid drops out while no motor is turning and gives 3 - gasket between pilot burner is leaking? - gasket between burner unit is leaking? - glass seal is l...
Installation instructions 31 optional: step burner function can be turned on and off. (only with remote) yes yes no - reset the receiver. - gas vlave broken, poor or loose contact. No - short circuit in wiring. - install a ground cable from the gas valve to the appliance. - check complete wiring abo...
Installation instructions 32 17.1 matrix 800/500-i 17 dimensional drawings.
Installation instructions 33 17.2 matrix 800/500-iil.
Installation instructions 34 17.3 matrix 800/500-iir.
Installation instructions 35 17.4 matrix 800/500-iii.
Installation instructions 36 17.5 matrix 800/650-i.
Installation instructions 37 17.6 matrix 800/650-iil.
Installation instructions 38 17.7 matrix 800/650-iir.
Installation instructions 39 17.8 matrix 800/650-iii.
Installation instructions 40 17.9 wall bracket.
Installation instructions 41 17.10 remote acces door.
Installation instructions 42 17.11 ventilation grid.
Installation instructions 43 17.12 adjustable feet.
Installation instructions 44 dealerinfo: www.Faber.Nl info@faber.Nl saturnus 8 nl - 8448 cc heerenveen postbus 219 nl - 8440 ae heerenveen.