Faber Presence Installation Manual And User's Manual

Summary of Presence

  • Page 1

    Presence installation guide and users manual gb ie gb ie 40011221-1138.

  • Page 2: Installation

    1 uk irl installation guide.

  • Page 3

    2 uk irl 1.1 1.2 1.3 1.4 1.5 1.6.

  • Page 4

    3 uk irl 1.7 1.8 2.1 2.2 2.3 2.4 2.5.

  • Page 5

    4 uk irl 2.6 3.1 3.2 3.3 4.1 4.2 a b.

  • Page 6

    5 uk irl 1 introduction the fire can only be installed by a competent person in accordance with the gas safety installation and use regulations. We urgently advise you to read this installation manual properly. This appliance complies with the guidelines for european gas appliances (gas appliances d...

  • Page 7

    6 uk irl 3.3 requirements flue system and outlets top outlet the flue connector collar is for connection to a 125 mm (5 inch) internal diameter pipe or liner according bs en 1856. The minimum effective height of the flue system must be 3 meter. Rear outlet in case of an installation in a masonry chi...

  • Page 8

    7 uk irl 6 placing the log set, decoration material it is not allowed to add different or more materials to the combustion chamber. Always keep the pilot burner free from decorative material! Do not toss all the decorative material onto the burner all at once, as the very fine dust may block the hol...

  • Page 9

    8 uk irl the same room or adjacent rooms running on high. • check if any other open flue appliances and flues in the same or adjacent rooms function correctly when this appliance is alight. 8 annual maintenance 8.1 service and cleaning: check and clean if necessary after checking: • the pilot light ...

  • Page 10

    9 uk irl 10 technical data gas category ii2h3+ ii2h3+ ii2h3+ type of appliance b11as b11as b11as reference gas g20 g30 g31 input - nett - gross kw 5,2 5.8 5,2 5,6 5,2 5.6 efficiency class 2 (76%) 2 (76%) 2 (76%) nox class 4 4 4 inlet pressure mbar 20 30 37 gas rate at 15ºc and 1013 mbar l/h 542 150 ...

  • Page 11

    10 uk irl 11 dimensions presence frameless top outlet.

  • Page 12

    11 uk irl 12 dimensions presence frameless rear outlet.

  • Page 13

    12 uk irl 13 dimensions presence framed top outlet.

  • Page 14

    13 uk irl 14 dimensions presence framed rear outlet.

  • Page 15: Users Manual

    14 uk irl users manual.

  • Page 16

    15 uk irl 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8.

  • Page 17

    16 uk irl 1.9 2.0 2.1 2.2 2.3 2.4 2.5.

  • Page 18

    17 uk irl 15 introduction because this appliance is a source of heat, air circulation will arise. That is why it is important that you do not use the fire shortly after a renovation. By natural air circulation moisture and volatile components from paint, building materials, floor coverings etc. That...

  • Page 19

    18 uk irl 18.3 placing the batteries • pull on the chain to take out the battery pack (fig 1.3) • unscrew and open the battery pack. Place 4 aa/lr6 alkaline long life batteries • close the pack and place the battery pack back in the appliance. • to avoid overheating the battery pack must always posi...

  • Page 20

    19 uk irl mounted within 4 metres of the appliance in the same room. The timer function (timer) can make the thermostat function once or twice on day temperature and one or twice on night temperature during a period of 24 hours. Factory settings thermostat and timer: day temperature 23° night temper...

  • Page 21

    20 uk irl pressing the off- key (fig. 2.0) or wait for ten seconds. • press the set–key (fig. 1.8) again and now p2 Ï(homecoming)will appear in the display screen, the time indication will start to blink and now set the starting time. • press the set–key (fig. 1.8) again, now p2 d(night)appears in t...

  • Page 22

    21 uk irl.

  • Page 23

    22 uk irl.

  • Page 24

    Www.Faber.Nl – info@faber.Nl saturnus 8 nl - 8448 cc heerenveen postbus 219 nl - 8440 ae heerenveen t. +31(0)513 656500 f. +31(0)513 656501.