    Version 3/13 - page 1 scirocco plus downdraft range hood internal or remote blower • installation instructions • use and care information read these instructions before you start installing this range hood warning: - to reduce the risk of a range top grease fire: a) never leave surface units unatten...

  • Page 2: Warning

    Version 3/13 - page 2 venting requirements determine which venting method is best for your application. Ductwork can extend either through the wall or the roof. The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork ...

  • Page 3: Avertissement

    Version 3/13 - page 3 rÈglements d'Évacuation confirmer la sortie d'évacuation - soit par le mur, soit par le toit. Utilisez une longueur de tuyauterie minimale avec les moindres de coudes pour la plus grande efficacité. Le diamètre de tuyauterie doit être uniforme. N'installez jamais 2 coudes ensem...

  • Page 4: Warning

    Version 3/13 - page 4 9 feet straight duct 2 - 90˚ elbows wall cap total system 9.0 feet 14.0 feet 0.0 feet 23.0 feet figure 2 5.0 feet 7.0 feet 12.0 feet 0.0 feet 45˚ elbow 90˚ elbow 90˚ flat elbow wall cap figure 1 tools needed for installation • saber saw or jig saw • drill • 1 1/4" wood drill bi...

  • Page 5

    Version 3/13 - page 5 product dimensions top trim widths: 30" (762 mm) vent 36" (914 mm) vent 14 " (357 mm) retractable vent height 27" (686 mm) for 30" (762 mm) vent 33" (838 mm) for 36" (914 mm) vent 13" (330 mm) 10 " (254 mm) 21⁄8 " (54 mm) 283⁄4" (730 mm) 3⁄8 " (9.5 mm) 11⁄2 " (38 mm) 13" (330 m...

  • Page 6

    Version 3/13 - page 6 cabinet cut out dimensions 22 30” 36” 30 36 figure 5 note: a = left, right ibdd600 ducting b = ducting ibdd600 down c = ducting ibdd600 to the rear d = power cord cut out for remote blower e = 10" ducting for remote blower a = cooktop overhang b = minimum width of the cooktop: ...

  • Page 7

    Version 3/13 - page 7 see the previous page with figure 5, and figure 6 above for reference. When using the ibdd600 internal blower installed on the front of the appliance use 6" round ducting. Holes for ducting are shown on figure 5, 6: (a) to the left or right (b) downwards, (c) to the rear. If th...

  • Page 8

    Version 3/13 - page 8 product dimensions installation using the ibdd600 internal blower figure 7 note: left side of diagram shows the ibdd600 mounted in front of the scirocco plus right side of the diagram shows the ibdd600 mounted behind the scirocco plus. The blower must be accessible to install t...

  • Page 9

    Version 3/13 - page 9 product dimensions installation using the remote blower figure 8 note: left side of diagram shows the remote blower ducting to the outside in front of the scirocco plus right side of the diagram shows the remote blower ducting to the rear of the scirocco plus. Note that the bac...

  • Page 10

    Version 3/13 - page 10 product installation please read safety and product dimensions pages before proceeding with installation 1) the downdraft system is installed directly behind the cooktop. For easiest installation, install the ventilation system first, then the cooktop.The ventilation system mu...

  • Page 11

    Version 3/13 - page 11 product installation 5) with the assistance of another person, lift the hood into the prepared cut out in the cabinet. The top mounting brackets should rest on the countertop. (figure 11) 6) secure the hood to the countertop with two screws. If possible, install the angle brac...

  • Page 12

    Version 3/13 - page 12 product installation continued figure 14 figure 15 8) remove the screws from the countertop and lift the hood back out of the cabinet. Pre-drill the marked mounting holes in the cabinet floor. 9) tighten the mounting brackets on the hood at the pre-marked positions 10) lay the...

  • Page 13

    Version 3/13 - page 13 installing ibdd600 in front of the hood, when venting to the back product installation figure 16 - when venting to the rear with the ibdd600 blower mounted on the front of the unit, some modification to the blower box is required (figure 16) - loosen the two screws holding the...

  • Page 14

    Version 3/13 - page 14 installing ibdd600 in back of the hood product installation the blower box can also be installed on the back of the hood to accommodate the installation of a cooking range, range top or wall oven / cook top in front of the hood. - remove the large cover on the back of the hood...

  • Page 15

    Version 3/13 - page 15 product installation - push the side covers into place on the mounting brackets on top of the counter and lock them in place (figure 29) - connect the appliance to the electric power supply (see the next page) - press the stainless top strip onto the hood. Push the on / off pu...

  • Page 16

    Version 3/13 - page 16 electrical connection warning:to reduce the risk of fire, electric shock, or injury to persons, observe the following: all electrical work should be performed by a qualified electrician in strict accordance with national regulations and local safety regulations. Installation, ...

  • Page 17

    Version 3/13 - page 17 electrical connection with remote blower - if using a remote blower, install a connection cable between the range hood and the remote blower. - see the remote blower instructions for more guidelines - additional knock outs should be used for the remote blower wiring - install ...

  • Page 18

    Version 3/13 - page 18 the retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. - for best results, the vent should be operating before cooking is started. - if you use large or tall utensils, place them on the large rear element or burner su...

  • Page 19

    Version 3/13 - page 19 downdraft system care surface of downdraft vent to avoid damaging the finish, clean downdraft vent with soap and water or stainless steel cleaner. Do not use scouring powder or abrasive solutions. Grease filter care frequently remove and clean the filters in the retractable se...

  • Page 20

    Version 3/13 - page 20 faber warranty & service (save for your records) all faber products are warranteed against any defect in materials or workmanship for the original purchaser for a period of 1 year from the date of original purchase. This warranty covers labor and replacement parts. To obtain w...

  • Page 21: Avertissement

    Version 3/13 - page 21 9 pi de conduit droit 2 coudes 90˚ capuchon de mur système total 9.0 pi 14.0 pi 0.0 pi 23.0 pi figure 2 5.0 pi 7.0 pi 12.0 pi 0.0 pi coude 45˚ coude 90˚ coude plat 90˚ capuchon de mu figure 1 plan du conduit le système scirocco courant descendant plus est conçu pour offrir une...

  • Page 22

    Version 3/13 - page 22 dimensions du produit top trim widths: 30" (762 mm) vent 36" (914 mm) vent 14 " (357 mm) retractable vent height 27" (686 mm) for 30" (762 mm) vent 33" (838 mm) for 36" (914 mm) vent 13" (330 mm) 10 " (254 mm) 21⁄8 " (54 mm) 283⁄4" (730 mm) 3⁄8 " (9.5 mm) 11⁄2 " (38 mm) 13" (3...

  • Page 23

    Version 3/13 - page 23 cabinet cut out dimensions 22 30” 36” 30 36 figure 5 note: a = gauche, droite ibdd600 conduits b = canalisation ibdd600 bas c = canalisation ibdd600 à l'arrière d cordon d'alimentation = taillé pour la soufflerie à télécommande e = 10 "conduits pour soufflerie à distance un su...

  • Page 24

    Version 3/13 - page 24 voir la page précédente à la figure 5, et la figure 6 ci-dessus à titre de référence. Lorsque vous utilisez le ventilateur interne ibdd600 installé sur le devant de la utilisation de l'appareil 6 "trous ronds conduits pour conduits sont indi- qués sur la figure 5, 6 : (a) vers...

  • Page 25

    Version 3/13 - page 25 dimensions du produit installation à l'aide du ventilateur interne ibdd600 figure 7 note: le côté gauche du diagramme montre la montée ibdd600 en face de la plus scirocco côté droit du diagramme montre la ibdd600 monté derrière le plus scirocco. Le ventilateur doit être access...

  • Page 26

    Version 3/13 - page 26 dimensions du produit installation à l'aide de la soufflerie à distance figure 8 note: le côté gauche du diagramme montre la soufflerie à distance conduits à l'extérieur en face de la plus scirocco le côté droit du diagramme montre la soufflerie à distance conduits à l'arrière...

  • Page 27

    Version 3/13 - page 27 installation du produit s'il vous plaÎt lire la sÉcuritÉ et dimensions du produit pages avant d'installer 1) le système de hotte est installée directement derrière la table de cuisson. Pour faciliter l'installation, installer le premier système de ventilation, puis le système ...

  • Page 28

    Version 3/13 - page 28 installation du produit 5) avec l'aide d'une autre personne, soulevez le capot dans la découpe préparée dans l'armoire. Le haut supports de montage doivent reposer sur le comptoir. (figure 11) 6) fixer la hotte sur le comptoir avec deux vis. Si possible, installer les équerres...

  • Page 29

    Version 3/13 - page 29 installation du produit suite figure 14 figure 15 8) retirez les vis du comptoir et soulevez le capot arrière de l'armoire. Pré-percer les trous marqués de montage dans le plancher de l'armoire. 9) serrer les supports de montage sur le capot au niveau des positions pré-marqués...

  • Page 30

    Version 3/13 - page 30 installation en ibdd600 avant du capot, quand l'évacuation vers le retour installation du produit figure 16 - lorsque évacuation vers l'arrière avec la soufflerie ibdd600 monté à l'avant de l'unité, une modification de la boîte de soufflage est nécessaire (figure 16) - desserr...

  • Page 31

    Version 3/13 - page 31 installation en ibdd600 arrière de la hotte installation du produit la boîte soufflante peut également être installé à l'arrière de la hotte pour recevoir le installation d'un plan de cuisson plage ou la plage en face de la hotte. - retirez le couvercle du grand sur le dos de ...

  • Page 32

    Version 3/13 - page 32 installation du produit - poussez sur le côté couvre en place sur les supports de montage sur le dessus du comptoir et de les verrouiller en place (figure 29) - connecter l'appareil à l'alimentation électrique (voir la page suivante) - appuyer sur la bande inoxydable haut sur ...

  • Page 33

    Version 3/13 - page 33 raccordement electrique avertissement: pour rÉduire le ris- que d'incendie,choc Électrique ou de blessures personnes, respecter ce qui suit: tous les travaux électriques doivent être effectués par un électricien qualifié en stricte conformité avec les réglementations nationale...

  • Page 34

    Version 3/13 - page 34 raccordement electrique avec telecommande ventilateur - si vous utilisez un ventilateur à distance, d'installer un câble de connexion entre la hotte et la soufflerie à distance. - voir les instructions pour la soufflerie à distance des lignes directrices plus - knock outs supp...

  • Page 35

    Version 3/13 - page 35 le système de ventilation aspirante escamotable est conçu pour éliminer les vapeurs de fumée de cuisson et les odeurs de la cuisine. - pour de meilleurs résultats, l'évent doit être opérationnel avant la cuisson est commencé. - si vous utilisez des ustensiles grands ou grand, ...

  • Page 36

    Version 3/13 - page 36 care system hotte surface de i'appareil pour éviter d'endommager la finition, nettoyer i'appareil avec du savon et de l'eau ou nettoyant pour acier inoxydable. Ne pas utiliser de poudre à récurer ou de solu- tions abrasives. Filtre à graisse soins foire enlever et nettoyer les...

  • Page 37

    Version 3/13 - page 37 faber garantie et service ( Économiser pour vos enregistrements ) faber garantit à l’utilisateur-acheteur d’origine que les produits faber vendus neufs par nous sont sans vice de matériel et de main-d’oeuvre d’origine pour une période d’un an à partir de la date d’achat. La ga...