Faber SERENE C11 Installation Manual

Summary of SERENE C11

  • Page 1

    Serene c11 emotion c11 intense c11 installation guide irl uk 40010716-0 822.

  • Page 2

    1 uk irl serene 1.1 1.2 1.3 1.4 1.5 c c c c b b b a a a d d.

  • Page 3

    > > > > 2 uk irl emotion / intense 2.1 2.2 2.3 2.4 d d c c e e a a a b b b.

  • Page 4

    3 uk irl content 1 introduction ......................................................................................... 4 2 safety and general information .................................................................. 5 3 installation requirements .................................................

  • Page 5

    > > > > 4 uk irl 1 introduction note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. Special features: • the serene can be build on all desired heights • room sealed appliance, inlet and outlet are led to the outside usin...

  • Page 6

    5 uk irl 2 safety and general information before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain...

  • Page 7

    > > > > 6 uk irl 3 installation requirements note: since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Due to the natural circulation of air, moist and volatile components from pai...

  • Page 8

    7 uk irl 1. Each 90-degree bend, which is in the horizontal area, counts for 2 meter 2. Each 45-degree bend, which is in the horizontal area, counts for 1 meter 3. Elbows and bends at the transition from horizontal to vertically are not to be counted 4. The wall mounted terminal counts for 1 meter 3...

  • Page 9

    > > > > 8 uk irl • a chimney that has previously been used for solid fuel must be swept before use. • the existing chimney needs to be airtight. • the existing chimney needs to have an opening of min. 150 x 150 mm. • the chimney needs to be intact and well looked after. • use the adjustable roof-mou...

  • Page 10

    9 uk irl 4 instruction for installation 4.1 gas connection • installation pipes should be in accordance with bs 6891. Pipe work from the meter to the appliance must be of adequate size. • the complete installation including the meter must be tested for soundness and purged as described in the above ...

  • Page 11

    > > > > 10 uk irl those prints once they are burned in the glass: o place the glass in front of the appliance and fix it with the glass clamps. Replace the frame. O check on visual leakages around the door sealing. 4.5 building the serene in a false chimney breast • if possible make a false ceiling ...

  • Page 12

    11 uk irl terminal or roof mounted terminal. To obtain a smoke sealed connection, the inner pipe must be 20 mm longer then the outside pipe 4.7 placing the log set never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in t...

  • Page 13

    > > > > 12 uk irl 5 commissioning (functional checks) 5.1 pilot ignition check • ignite the pilot light as described in the user manual • check if the pilot burner stays alight • extinguish the pilot burner 5.2 check functional burner and pilot burner the appliance is preset to give the correct heat...

  • Page 14

    13 uk irl 6 handing over (final check and customer briefing) instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries advise the customer how to clean the appliance including the glass hand over these instructions including the user guid...

  • Page 15

    > > > > 14 uk irl 7.3 converting to butane/propane rebuilding to another gas category is only possible by exchanging the complete burner plate. Ask your local dealer and bring the serial number of the appliance. A. Pilot assembly b. Burner c. Fixation plate d. Injector e. Gas control f. Receiver.

  • Page 16

    15 uk irl appendix a: example calculation calculation 1: calculating horizontal extension fig. 2a: flue length c + e = 1m + 1m 2 m elbows d = 2m 2 m total horizontal extension 4 m measure or calculate effective height (hvert) flue length a 1 m roof mounted terminal 1 m total effective height 2 m alw...

  • Page 17

    > > > > 16 uk irl appendix b: flue restrictor determine the right flue restrictor: • calculate the total horizontal- and vertical length of the flue, according to the calculations in appendix a • determine according to the table the right flue restrictor size • when meeting an x, and when the values...

  • Page 18

    17 uk irl appendix c: technical specifications serene logburner logburner logburner country uk / irl uk / irl uk / irl cat ii 2e+3+ ii 2h3+ ii 2h3+ appliance type c11 / c31 c11 / c31 c11 / c31 reference gas g20 g30 g31 input (nett) kw 6.0 6.0 6.0 efficiency class 2 2 2 inlet pressure mbar 20 30 37 g...

  • Page 19

    > > > > 18 uk irl appendix d: dimensions serene.

  • Page 20

    19 uk irl appendix e: dimensions emotion.

  • Page 21

    > > > > 20 uk irl appendix f: dimensions intense.

  • Page 22

    21 uk irl appendix g: dimensions convection grid.

  • Page 23

    > > > > 22 uk irl.

  • Page 24

    Www.Faber.Nl – info@faber.Nl saturnus 8 nl - 8448 cc heerenveen postbus 219 nl - 8440 ae heerenveen t. +31(0)513 656500 f. +31(0)513 656501.