Facom 779.CL2 Instruction Manual - page 3
EN
SPECIFICATIONS
Weight
Luminosity
In-chargepowerinput
Voltage
Protectionrating
Storagetemperature
Operatingtemperature
Battery
779.CL21
480g
1000Luxà0,5meter
14W
7,2V----
IP64IK9
-20°C➙+70°C
-10°C➙+50°C
Ni-MHpackbatteries1000mAhmin
779.CL12
Charger
100-230V50-60Hz-12VAdoubleinsulationoutput
Protectionrating
IP20
Chargingtime
1,5hours
Autonomy
6hours(newLEDsandbatteries)
Chargingtemperature
5°C➜ +45°C
Ni-MHbatteriesareconsumablesnotcoveredbytheguarantee.
Thelamp’sautonomyisspecifiedfornewbatteries.
OPERATION
- Beforefirstuse,chargethe
779.CL2
inspectionlampfor3hours.
Themaximumautonomyisreachedafter3completecharge-dischargecycles.
- Power indicator on the base: green LED On.
The LEDs on the lamp blink to indicate charging. Once charging is complete, the LEDs are switched off.
- When switched on, the lamp’s intensity increases gradually to preserve LED lifetime.
- The lamp’s light intensity rises gradually when it is turned on to preserve the lifetime of the LEDs.
- When the operating time left drops to 1/4 hour, the lamp switches off and switches on instantly every 15 seconds.
- Batteries are sensitive to temperature: autonomy variations can occur at low temperatures
- The charging system is fitted with an automatic thermal circuit breaker.
- The
779.CL2
inspection lamp resists to most products and solvents used in automotive
repair and industrial shops (white spirit, petrol, diesel fuel, brake fluid, engine oil).
MAINTENANCE
- Never immerse the
779.CL2
inspection lamp in a cleaning product.
- Use a dry cloth with soapy water to clean your
779.CL2
inspection lamp.
- Use only FACOM spare battery packs, reference
779.CL16
.
- Using non-compliant packs or improper usage can cause leaks or an explosion which would damage the lamp.
- Use only the
779.CL13
mains adapter supplied by FACOM. Using other mains adapters can cause
electrical hazard and start a fire.
- Before any prolonged use of the lamp, perform a full discharge-recharge cycle.
+
779.CL2
+
☞
250 mm
45mm
55 mm
779.CL16
779.CL21
779.CL12
779.CL13
+
+
779.CL16
Ni-MH
➡
779.CL14
OPTION
12V/24V
EC statement of compliance:
WE, FACOM S.A., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, STATE UNDER OUR LIABILITY THAT THE FOLLOWING PRODUCTS:
779.CL2 – CORDLESS INSPECTION LAMP by FACOM
COMPLY WITH THE PROVISIONS SET OUT IN THE FOLLOWING EUROPEAN DIRECTIVES:
- ‘’LOW VOLTAGE’’ DIRECTIVE 73/23/CEE AMENDED BY DIRECTIVE 93/68/CEE
- ‘’EMC’’ DIRECTIVE 89/336/CEE AMENDED BY DIRECTIVE 93/68/CEE
AND COMPLY WITH THE PROVISIONS SET OUT IN THE FOLLOWING HARMONISED EUROPEAN STANDARDS:
- EN 55015 - EN 55022 - EN 55024
- EN 60598-1 - EN 60598-2-8 - EN 61000-3-2 - EN 61000-3-3 - EN 61547
30.11.04
Quality Manager
04