Fahrenheat FLCH4R Installation, Operation & Maintenance Instructions Manual

Summary of FLCH4R

  • Page 1

    Flch4r garage and utility electric heater installation, operation & maintenance instructions warning important instructions model no. Volts amps watts btu/hr phase min fuse size* high low high low high low flch4r 208 17.3 8.66 3600 1800 12284 6142 1 25 240 20 10 4800 2400 16378 8189 1 25 5200-11227-...

  • Page 2: Warning

    Warning to prevent a possible fire, injury to persons or damage to the heater, adhere to the following: 1. Disconnect all power coming to heater at main service panel before wiring or servicing. 2. All wiring procedures and connections must be in accordance with the national and local codes having j...

  • Page 3: Installation Instructions

    For wall mount applications for ceiling mount applications detailed bracket assembly illustration installation instructions figure 4 wall mounting figure 5 ceiling mounting 3 figure 6 minimum clearances 30° tilt warning: fall hazard - heater must be attached to a joist with 3 screws (two at keyhole ...

  • Page 4: Warning

    After heater has been properly mounted to the building structure and appropriate branch circuit wiring has been routed to the heater location in accordance with the national electrical code and local codes, the heater is now ready for the heater to be connected to the branch circuit. Warning risk of...

  • Page 5: Wiring - Instructions

    5 figure 12: wiring diagram for flch4r figure 13: field wiring connected to heater wires using wire nuts make the three connections as shown using wire nuts or approved connectors making sure all connections are tight. Carefully push the wires and connections into wiring compartment as shown making ...

  • Page 6: Operating - Instructions

    6 heater control panel: 1. Heater must be properly installed and correctly wired before operation. 2. Turn power supply to heater “on” at main switch panel. 3. Once the heater has power, the red power light will be on. 4. Pushing the red power button will turn the heater on and off. When this button...

  • Page 7: Troubleshooting Guide

    7 troubleshooting guide problem cause solution fan stays on when heat shuts off. 1. Fan delay cycles on/off until elements are cool 1. Heater is operating correctly for models. Heating element does not glow red 1. Heating element is made of stainless steel and will not glow red to produce heat. 1. H...

  • Page 8

    Limited warranty the products covered by this installation manual, manufactured and/or sold by marley engineered products, are warranted against defects in workmanship and materials for one year from date of purchase. This warranty does not apply to damage from accident, misuse, or alteration; nor w...