    E2904i induction boiling table user instructions section 1 – general description section 2 – safety and operation section 3 – cooking hints section 4 – maintenance and cleaning important this appliance must be installed by a competent person in compliance with the regulations in force at the time. R...

  • Page 2

    Section 2 - safety and operation warning if glass-ceramic top is cracked or broken, immediately disconnect appliance from power supply and contact your service agent. Warning persons with pacemakers should consult their g.P. Before operating this appliance. This unit operates at 20khz and this may a...

  • Page 3

    Each cooking zone is controlled by a marked, variable control from 1 (lowest) to 10 (highest). The ideal setting for simmering or fast boiling pans of varying size will quickly be established through experience. See figure 4. Each control has a green led indicator. When a cooking zone is switched on...

  • Page 4

    Note: a good pan is made of ferrous material and there- fore is magnetic so that it reacts to the magnetic induction field. Ensure your pots are magnetic or induction approved. If a pan base is damaged or warped, ie concave or convex, discontinue use or replace as this could seriously affect perform...

  • Page 5

    Section 3 - cooking hints 1. Before use, ensure that hob surface is clean, dry and free of grease. Remove any burnt on food debris. 2. Familiarise yourself with the cooking area and the control settings. 3. Each cooking zone has a power capacity of 5kw. 4. Each zone is governed by an individual ener...

  • Page 6

    Error code table if any fault occurs during use, an error code corresponding to the details below will be displayed as a series of flashes. For example, 6 short flashes followed by a long flash would indicate error code 06. The codes will help determine unit faults and the table lists actions requir...

  • Page 7

    01 hardware over coil use of unsuitable pan material re-set required defective coil use suitable pan. Switch unit off for 10 seconds, then on engineer required 02 no inductor coil current re-set unit inductor coil connection failure switch unit off for 10 seconds, then on engineer required 03 heat s...

  • Page 8

    10 communication error re-set required failure on lin or can-bus switch unit off for 10 seconds, then on engineer required 11 initialisation error re-set required software failed when initialising hardware switch unit off for 10 seconds, then on wait. Generator will re-set every 30 seconds engineer ...